A multicentered evaluation of ablation at higher power guided by ablation index: Establishing ablation targets for pulmonary vein isolation

被引:88
|
作者
Dhillon, Gurpreet [1 ]
Ahsan, Syed [1 ]
Honarbakhsh, Shohreh [1 ]
Lim, Wei [1 ]
Baca, Marco [1 ]
Graham, Adam [1 ]
Srinivasan, Neil [1 ]
Sawhney, Vinit [1 ]
Sporton, Simon [1 ]
Schilling, Richard J. [1 ]
Chow, Anthony [1 ]
Ginks, Matthew [2 ]
Sohal, Manav [3 ,4 ]
Gallagher, Mark M. [3 ,4 ]
Hunter, Ross J. [1 ]
机构
[1] Barts Hlth NHS Trust, St Bartholomews Hosp, Barts Heart Ctr, Dept Cardiac Electrophysiol, London EC1A 7BE, England
[2] Oxford Univ Hosp NHS Fdn Trust, John Radcliffe Hosp, Oxford Heart Ctr, Dept Cardiol, Oxford, England
[3] St George Hosp, Dept Cardiol, London, England
[4] St Anthony Hosp, Dept Cardiol, Sutton, Surrey, England
关键词
ablation index; atrial fibrillation; pulmonary vein isolation; CONTACT FORCE; ATRIAL-FIBRILLATION; RADIOFREQUENCY ABLATION; CATHETER ABLATION; RECONNECTION; TRIAL;
D O I
10.1111/jce.13813
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Pulmonary vein isolation (PVI) using high power delivered by SmartTouch Surround Flow (STSF) catheters guided by ablation index (AI) was evaluated in a multicenter registry. Methods Patients with paroxysmal AF underwent PVI with STSF catheters using 30 W on the posterior wall and 40 W elsewhere. AI targets were 350 posterior walls and 450 elsewhere. Procedures were compared with controls using conventionally irrigated contact force-sensing catheters using conventional powers (25 W posterior wall and 30 W elsewhere) guided by force-time integral (no agreed targets). The waiting period of 30 minutes was observed before adenosine administration to assess acute pulmonary vein (PV) reconnection. Results One hundred patients from four centers were included: 50 patients in the high power ablation index (HPAI) group and 50 controls. Procedure time was 22% shorter in the HPAI group (156 [133.8-179] vs 199 [178.5-227] minutes; P < 0.001). Duration of the radiofrequency application was 37% shorter in the HPAI group (27.2 [21.5-35.8] vs 43.2 [35.1-52.1] minutes; P < 0.001). Acute PV reconnection was reduced (28 of 200 [14%] vs 48 of 200 [24%] veins; P = 0.015). Reconnection was predicted by a largest interlesion distance greater than 6 mm, a lesion with impedance drop less than 2.5 omega, contact force less than 6 g, or less than 68% of the regional AI target (all P < 0.001). Freedom from atrial arrhythmia at 1 year off antiarrhythmic drugs after a single procedure was 78% in the HPAI group vs 64% in the control group (P = 0.186). Conclusion High-powered ablation guided by AI was safe and led to shorter procedure times with reduced acute PV reconnection compared with conventional ablation.
引用
收藏
页码:357 / 365
页数:9
相关论文
共 50 条
  • [31] Pulmonary vein isolation using cryoballoon ablation versus RF ablation using ablation index following the CLOSE protocol: A prospective randomized trial
    Theis, Cathrin
    Kaiser, Bastian
    Kaesemann, Philipp
    Hui, Felix
    Pirozzolo, Giancarlo
    Bekeredjian, Raffi
    Huber, Carola
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (05) : 866 - 873
  • [32] High density mapping guided partial antral ablation for a pulmonary vein isolation
    Hwang, Jongmin
    Han, Seongwook
    Hwang, Chun
    Park, Hyoung-Seob
    Lee, Cheol Hyun
    Kim, In-Cheol
    Cho, Yun-Kyeong
    Chung, Jin Wook
    Yoon, Hyuck-Jun
    Kim, Hyungseop
    Nam, Chang-Wook
    Hur, Seung-Ho
    Kim, Jin Young
    Kim, Yun Seok
    Jang, Woo Sung
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [33] High-power short-duration ablation index–guided pulmonary vein isolation protocol using a single catheter
    Patrick Badertscher
    Sven Knecht
    Florian Spies
    Gian Völlmin
    Beat Schaer
    Nicolas Schärli
    Flurina Bosshard
    Stefan Osswald
    Christian Sticherling
    Michael Kühne
    Journal of Interventional Cardiac Electrophysiology, 2022, 65 : 633 - 642
  • [34] Evaluation of pulmonary vein reconnection during repeat ablation for atrial fibrillation, following primary pulmonary vein isolation using laser balloon ablation as compared to radiofrequency catheter ablation
    Koopman, P.
    Brughmans, S.
    Dilling-Boer, D.
    Knevels, R.
    Leenders, F.
    Phlips, T.
    Schurmans, J.
    Vijgen, J.
    ACTA CARDIOLOGICA, 2022, 77 : 14 - 14
  • [35] High density mapping guided partial antral ablation for a pulmonary vein isolation
    Jongmin Hwang
    Seongwook Han
    Chun Hwang
    Hyoung-Seob Park
    Cheol Hyun Lee
    In-Cheol Kim
    Yun-Kyeong Cho
    Jin Wook Chung
    Hyuck-Jun Yoon
    Hyungseop Kim
    Chang-Wook Nam
    Seung-Ho Hur
    Jin Young Kim
    Yun Seok Kim
    Woo Sung Jang
    Scientific Reports, 11
  • [36] The Impact of Regional Maximum Tolerated Interlesion Distance on the Long-Term Ablation Outcomes in Ablation Index Guided Pulmonary Vein Isolation for Atrial Fibrillation
    Kiedrowicz, Radoslaw M. M.
    Wielusinski, Maciej
    Krasnik, Wojciech
    Jankowska, Olga
    Zakrzewski, Szymon
    Duda, Lukasz
    Peregud-Pogorzelska, Malgorzata
    Kladna, Aleksandra
    Kazmierczak, Jaroslaw
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (15)
  • [37] High-sensitivity Troponin I and Ablation Effectiveness Quotient after Ablation Index-guided pulmonary vein isolation—markers of arrhythmia recurrence?
    Pedro A. Sousa
    Luís Puga
    Sérgio Barra
    Diana Campos
    Natália António
    Luís Elvas
    Lino Gonçalves
    Journal of Interventional Cardiac Electrophysiology, 2022, 65 : 115 - 121
  • [38] Impact of baseline impedance of pulmonary vein antrum on success of catheter ablation for paroxysmal atrial fibrillation guided by ablation index
    Sun, Yuanjun
    Xiao, Xianjie
    Yin, Xiaomeng
    Gao, Lianjun
    Yu, Xiaohong
    Zhang, Rongfeng
    Wang, Zhongzhen
    Dai, Shiyu
    Yang, Yanzong
    Xia, Yunlong
    BMC CARDIOVASCULAR DISORDERS, 2022, 22 (01)
  • [39] Impact of baseline impedance of pulmonary vein antrum on success of catheter ablation for paroxysmal atrial fibrillation guided by ablation index
    Yuanjun Sun
    Xianjie Xiao
    Xiaomeng Yin
    Lianjun Gao
    Xiaohong Yu
    Rongfeng Zhang
    Zhongzhen Wang
    Shiyu Dai
    Yanzong Yang
    Yunlong Xia
    BMC Cardiovascular Disorders, 22
  • [40] Early Cryoballoon Pulmonary Vein Isolation Ablation Experience in Radiofrequency Ablation Experienced Operators
    Siddoway, Donald
    Friehling, Mati
    Voigt, Andrew
    Saba, Samir
    Jain, Sandeep
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2014, 25 (05) : 569 - 569