Lightweight, compact, and high-performance 3T MR system for imaging the brain and extremities

被引:68
|
作者
Foo, Thomas K. F. [1 ]
Laskaris, Evangelos [1 ]
Vermilyea, Mark [1 ]
Xu, Minfeng [1 ]
Thompson, Paul [1 ]
Conte, Gene [1 ]
Van Epps, Christopher [1 ]
Immer, Christopher [1 ]
Lee, Seung-Kyun [1 ,2 ]
Tan, Ek T. [1 ]
Graziani, Dominic [1 ]
Mathieu, Jean-Baptise [3 ]
Hardy, Christopher J. [1 ]
Schenck, John F. [1 ]
Fiveland, Eric [1 ]
Stautner, Wolfgang [1 ]
Ricci, Justin [1 ]
Piel, Joseph [1 ]
Park, Keith [1 ]
Hua, Yihe [1 ]
Bai, Ye [1 ]
Kagan, Alex [1 ]
Stanley, David [5 ]
Weavers, Paul T. [4 ,5 ]
Gray, Erin [4 ]
Shu, Yunhong [4 ]
Frick, Matthew A. [4 ]
Campeau, Norbert G. [4 ]
Trzasko, Joshua [4 ]
Huston, John, III [4 ]
Bernstein, Matt A. [4 ]
机构
[1] GE Global Res, 1 Res Circle, Niskayuna, NY 12309 USA
[2] Sungkyunkwan Univ, Dept Biomed Engn, Suwon, South Korea
[3] GE Healthcare, Florence, SC USA
[4] Mayo Clin, Dept Radiol, Rochester, MN USA
[5] GE Healthcare, Waukesha, WI USA
关键词
PERIPHERAL-NERVE STIMULATION; TRANSVERSE GRADIENT COILS; CONCOMITANT FIELDS; HEAD; DISTORTION; DIFFUSION; DESIGN; LIMITS; FMRI; BODY;
D O I
10.1002/mrm.27175
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To build and evaluate a small-footprint, lightweight, high-performance 3T MRI scanner for advanced brain imaging with image quality that is equal to or better than conventional whole-body clinical 3T MRI scanners, while achieving substantial reductions in installation costs. Methods: A conduction-cooled magnet was developed that uses less than 12 liters of liquid helium in a gas-charged sealed system, and standard NbTi wire, and weighs approximately 2000 kg. A 42-cm inner-diameter gradient coil with asymmetric transverse axes was developed to provide patient access for head and extremity exams, while minimizing magnet-gradient interactions that adversely affect image quality. The gradient coil was designed to achieve simultaneous operation of 80-mT/m peak gradient amplitude at a slew rate of 700 T/m/s on each gradient axis using readily available 1-MVA gradient drivers. Results: In a comparison of anatomical imaging in 16 patients using T2-weighted 3D fluid-attenuated inversion recovery (FLAIR) between the compact 3T and whole-body 3T, image quality was assessed as equivalent to or better across several metrics. The ability to fully use a high slew rate of 700 T/m/s simultaneously with 80-mT/m maximum gradient amplitude resulted in improvements in image quality across EPI, DWI, and anatomical imaging of the brain. Conclusions: The compact 3T MRI system has been in continuous operation at the Mayo Clinic since March 2016. To date, over 200 patient studies have been completed, including 96 comparison studies with a clinical 3T whole-body MRI. The increased gradient performance has reliably resulted in consistently improved image quality.
引用
收藏
页码:2232 / 2245
页数:14
相关论文
共 50 条
  • [11] 3T MR imaging: The pros and cons - Reply
    Bradley, WG
    Safar, FG
    Hurtado, C
    Ord, J
    Alksne, JF
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2004, 25 (09) : 1455 - 1455
  • [12] In vivo sodium MR imaging of the abdomen at 3T
    Judy R. James
    Anshuman Panda
    Chen Lin
    Ulrike Dydak
    Brian M. Dale
    Navin Bansal
    Abdominal Imaging, 2015, 40 : 2272 - 2280
  • [13] MR safety and imaging of Neuroform stents at 3T
    Nehra, A
    Moran, CJ
    Cross, DT
    Derdeyn, CP
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2004, 25 (09) : 1476 - 1478
  • [14] A High-performance Compact Photoacoustic Tomography System for In Vivo Small-animal Brain Imaging
    Upputuri, Paul Kumar
    Periyasamy, Vijitha
    Kalva, Sandeep Kumar
    Pramanik, Manojit
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2017, (124):
  • [15] Reducing PNS with minimal performance penalties via simple pulse sequence modifications on a high-performance compact 3T scanner
    In, Myung-Ho
    Shu, Yunhong
    Trzasko, Joshua D.
    Yarach, Uten
    Kang, Daehun
    Gray, Erin M.
    Huston, John
    Bernstein, Matt A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (15):
  • [16] Fast Distortion-Free T2 Imaging Using DIADEM Combined with Tilted-CAIPI On a Compact 3T Scanner with High-Performance Gradients
    In, M. H.
    Kang, D.
    Yarach, U.
    Shu, Y.
    Trzasko, J. D.
    Huston, J.
    Bernstein, M. A.
    MEDICAL PHYSICS, 2019, 46 (06) : E387 - E387
  • [17] Multimodal imaging: Simultaneous EEG in a 3T Hybrid MR-PET system
    Neuner, I.
    Warbrick, T.
    Tellmann, L.
    Kops, E. Rota
    Arrubla, J.
    Boers, F.
    Herzog, H.
    Shah, N. J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 702 : 37 - 38
  • [18] MR Imaging of the nerve root of the lumbar vertebra with a 3T high field machine
    Mizuuchi, N.
    Maruyama, K.
    Moroi, T.
    Imura, C.
    Isobe, I.
    Usagawa, T.
    Iriguchi, N.
    2007 IEEE/ICME INTERNATIONAL CONFERENCE ON COMPLEX MEDICAL ENGINEERING, VOLS 1-4, 2007, : 786 - 789
  • [19] High Performance Gradient On a Compact 3T MR Scanner for Functional MRI Geometrical Distortion Reduction: Preliminary Experience and Comparison with Conventional Whole-Body 3T Scanner
    Kang, D.
    In, M.
    Jo, H.
    Tan, E. K.
    Yarach, U.
    Meyer, N.
    Trzasko, J.
    Huston, J.
    Foo, T.
    Bernstein, M.
    Shu, Y.
    MEDICAL PHYSICS, 2019, 46 (06) : E387 - E387
  • [20] Quantitative PET imaging with the 3T MR-BrainPET
    Weirich, C.
    Scheins, J.
    Lohmann, P.
    Tellmann, L.
    Byars, L.
    Michel, C.
    Kops, E. Rota
    Brenner, D.
    Herzog, H.
    Shah, N. J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 702 : 26 - 28