摘要
One of the major concerns associated with high-performance gradients is peripheral nerve stimulation (PNS) of the subject during MRI exams. Since the installation, more than 680 volunteer subjects (patients and controls) have been scanned on a compact 3 T MRI system with high-performance gradients, capable of 80 mT m(-1)gradient amplitude and 700 T m(-1)s(-1)slew rate simultaneously. Despite PNS concerns associated with the high-performance gradients, due to the smaller physical dimensions of the gradient coils, minimal or no PNS sensation was reported with most pulse sequences. The exception was PNS reported by only five of 252 subjects (about 2%) scanned with a specific 3D fast spin echo pulse sequence (3DFLAIR). Rather than derating the entire system performance across all pulse sequences and all gradient lobes, we addressed reported PNS effect with a simple and specific modification to the targeted lobes of the problematic pulse sequence. in addition, the PNS convolutional model was adapted to predict sequence-specific PNS threshold level and its reduction after derating. The effectiveness of the targeted pulse sequence modification was demonstrated by successfully re-scanning four of the subjects who previously reported PNS sensations without further reported PNS. The pulse sequence modification did not result in noticeable degradation of image quality or substantial increase in scan time. The results demonstrated that PNS was rarely reported on the compact 3 T, and when it was, utilizing a specific modification of the gradient waveform causing PNS was an effective strategy, rather than derating the performance of the entire gradient system.
引用
收藏
页数:8
相关论文
共 16 条
  • [1] Improved Brain MR Imaging from a Compact, Lightweight 3T Scanner with High-Performance Gradients
    Camerucci, Emanuele
    Campeau, Norbert G.
    Trzasko, Joshua D.
    Gray, Erin M.
    Bernstein, Matt A.
    Cogswell, Petrice M.
    Shu, Yunhong
    Foo, Thomas K.
    Huston, John, III
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 55 (01) : 166 - 175
  • [2] Lightweight, compact, and high-performance 3T MR system for imaging the brain and extremities
    Foo, Thomas K. F.
    Laskaris, Evangelos
    Vermilyea, Mark
    Xu, Minfeng
    Thompson, Paul
    Conte, Gene
    Van Epps, Christopher
    Immer, Christopher
    Lee, Seung-Kyun
    Tan, Ek T.
    Graziani, Dominic
    Mathieu, Jean-Baptise
    Hardy, Christopher J.
    Schenck, John F.
    Fiveland, Eric
    Stautner, Wolfgang
    Ricci, Justin
    Piel, Joseph
    Park, Keith
    Hua, Yihe
    Bai, Ye
    Kagan, Alex
    Stanley, David
    Weavers, Paul T.
    Gray, Erin
    Shu, Yunhong
    Frick, Matthew A.
    Campeau, Norbert G.
    Trzasko, Joshua
    Huston, John, III
    Bernstein, Matt A.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (05) : 2232 - 2245
  • [3] The effect of spiral trajectory correction on pseudo-continuous arterial spin labeling with high-performance gradients on a compact 3T scanner
    Kang, Daehun
    Yarach, Uten
    In, Myung-Ho
    Gray, Erin M.
    Trzasko, Joshua D.
    Jo, Hang Joon
    Shu, Yunhong
    Huston, John, III
    Bernstein, Matt A.
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (01) : 192 - 205
  • [4] Evaluation of the B0 Field Uniformity On a Compact 3T MR Scanner with High Performance Gradients
    Shu, Y.
    Tao, S.
    Xu, M.
    Laskaris, E.
    Foo, T.
    Weavers, P.
    Trzasko, J.
    Huston, J.
    Bernstein, M.
    MEDICAL PHYSICS, 2017, 44 (06) : 3048 - 3049
  • [5] High Performance Gradient On a Compact 3T MR Scanner for Functional MRI Geometrical Distortion Reduction: Preliminary Experience and Comparison with Conventional Whole-Body 3T Scanner
    Kang, D.
    In, M.
    Jo, H.
    Tan, E. K.
    Yarach, U.
    Meyer, N.
    Trzasko, J.
    Huston, J.
    Foo, T.
    Bernstein, M.
    Shu, Y.
    MEDICAL PHYSICS, 2019, 46 (06) : E387 - E387
  • [6] Fast Distortion-Free T2 Imaging Using DIADEM Combined with Tilted-CAIPI On a Compact 3T Scanner with High-Performance Gradients
    In, M. H.
    Kang, D.
    Yarach, U.
    Shu, Y.
    Trzasko, J. D.
    Huston, J.
    Bernstein, M. A.
    MEDICAL PHYSICS, 2019, 46 (06) : E387 - E387
  • [7] Improved Resting-State Functional MRI Using Multi-Echo Echo-Planar Imaging on a Compact 3T MRI Scanner with High-Performance Gradients
    Kang, Daehun
    In, Myung-Ho
    Jo, Hang Joon
    Halverson, Maria A.
    Meyer, Nolan K.
    Ahmed, Zaki
    Gray, Erin M.
    Madhavan, Radhika
    Foo, Thomas K.
    Fernandez, Brice
    Black, David F.
    Welker, Kirk M.
    Trzasko, Joshua D.
    Huston III, John
    Bernstein, Matt A.
    Shu, Yunhong
    SENSORS, 2023, 23 (09)
  • [8] High Resolution 3D FGRE Is Feasible for Brain MR Elastography with High Performance Compact 3T Scanner in Healthy Volunteers and Patients with Brain Tumors
    Arani, A.
    Grimm, R.
    Murphy, M.
    Trzasko, J.
    Ehman, R.
    Bernstein, M.
    Huston, J.
    MEDICAL PHYSICS, 2019, 46 (06) : E507 - E507
  • [9] Simple, Compact, Robust and High-performance Power module T-PM (Transfer-molded Power Module)
    Ueda, Tetsuya
    Yoshimatsu, Naoki
    Kimoto, Nobuyoshi
    Nakajima, Dai
    Kikuchi, Masao
    Shinohara, Toshiaki
    2010 22ND INTERNATIONAL SYMPOSIUM ON POWER SEMICONDUCTOR DEVICES AND ICS (ISPSD), 2010, : 47 - 50
  • [10] Distortion-Free Imaging: A Double Encoding Method (DIADEM) Combined With Multiband Imaging for Rapid Distortion-Free High-Resolution Diffusion Imaging on a Compact 3T With High-Performance Gradients
    In, Myung-Ho
    Tan, Ek Tsoon
    Trzasko, Joshua D.
    Shu, Yunhong
    Kang, Daehun
    Yarach, Uten
    Tao, Shengzhen
    Gray, Erin M.
    Huston, John, III
    Bernstein, Matt A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2020, 51 (01) : 296 - 310