Lightweight, compact, and high-performance 3T MR system for imaging the brain and extremities

被引:68
|
作者
Foo, Thomas K. F. [1 ]
Laskaris, Evangelos [1 ]
Vermilyea, Mark [1 ]
Xu, Minfeng [1 ]
Thompson, Paul [1 ]
Conte, Gene [1 ]
Van Epps, Christopher [1 ]
Immer, Christopher [1 ]
Lee, Seung-Kyun [1 ,2 ]
Tan, Ek T. [1 ]
Graziani, Dominic [1 ]
Mathieu, Jean-Baptise [3 ]
Hardy, Christopher J. [1 ]
Schenck, John F. [1 ]
Fiveland, Eric [1 ]
Stautner, Wolfgang [1 ]
Ricci, Justin [1 ]
Piel, Joseph [1 ]
Park, Keith [1 ]
Hua, Yihe [1 ]
Bai, Ye [1 ]
Kagan, Alex [1 ]
Stanley, David [5 ]
Weavers, Paul T. [4 ,5 ]
Gray, Erin [4 ]
Shu, Yunhong [4 ]
Frick, Matthew A. [4 ]
Campeau, Norbert G. [4 ]
Trzasko, Joshua [4 ]
Huston, John, III [4 ]
Bernstein, Matt A. [4 ]
机构
[1] GE Global Res, 1 Res Circle, Niskayuna, NY 12309 USA
[2] Sungkyunkwan Univ, Dept Biomed Engn, Suwon, South Korea
[3] GE Healthcare, Florence, SC USA
[4] Mayo Clin, Dept Radiol, Rochester, MN USA
[5] GE Healthcare, Waukesha, WI USA
关键词
PERIPHERAL-NERVE STIMULATION; TRANSVERSE GRADIENT COILS; CONCOMITANT FIELDS; HEAD; DISTORTION; DIFFUSION; DESIGN; LIMITS; FMRI; BODY;
D O I
10.1002/mrm.27175
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To build and evaluate a small-footprint, lightweight, high-performance 3T MRI scanner for advanced brain imaging with image quality that is equal to or better than conventional whole-body clinical 3T MRI scanners, while achieving substantial reductions in installation costs. Methods: A conduction-cooled magnet was developed that uses less than 12 liters of liquid helium in a gas-charged sealed system, and standard NbTi wire, and weighs approximately 2000 kg. A 42-cm inner-diameter gradient coil with asymmetric transverse axes was developed to provide patient access for head and extremity exams, while minimizing magnet-gradient interactions that adversely affect image quality. The gradient coil was designed to achieve simultaneous operation of 80-mT/m peak gradient amplitude at a slew rate of 700 T/m/s on each gradient axis using readily available 1-MVA gradient drivers. Results: In a comparison of anatomical imaging in 16 patients using T2-weighted 3D fluid-attenuated inversion recovery (FLAIR) between the compact 3T and whole-body 3T, image quality was assessed as equivalent to or better across several metrics. The ability to fully use a high slew rate of 700 T/m/s simultaneously with 80-mT/m maximum gradient amplitude resulted in improvements in image quality across EPI, DWI, and anatomical imaging of the brain. Conclusions: The compact 3T MRI system has been in continuous operation at the Mayo Clinic since March 2016. To date, over 200 patient studies have been completed, including 96 comparison studies with a clinical 3T whole-body MRI. The increased gradient performance has reliably resulted in consistently improved image quality.
引用
收藏
页码:2232 / 2245
页数:14
相关论文
共 50 条
  • [1] Improved Brain MR Imaging from a Compact, Lightweight 3T Scanner with High-Performance Gradients
    Camerucci, Emanuele
    Campeau, Norbert G.
    Trzasko, Joshua D.
    Gray, Erin M.
    Bernstein, Matt A.
    Cogswell, Petrice M.
    Shu, Yunhong
    Foo, Thomas K.
    Huston, John, III
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 55 (01) : 166 - 175
  • [2] Editorial for "Improved Brain MR Imaging from a Compact, Lightweight 3 Tesla Scanner With High Performance Gradients"
    Orsi, Gergely
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 55 (01) : 176 - 177
  • [3] High Resolution 3D FGRE Is Feasible for Brain MR Elastography with High Performance Compact 3T Scanner in Healthy Volunteers and Patients with Brain Tumors
    Arani, A.
    Grimm, R.
    Murphy, M.
    Trzasko, J.
    Ehman, R.
    Bernstein, M.
    Huston, J.
    MEDICAL PHYSICS, 2019, 46 (06) : E507 - E507
  • [4] Advantages and pitfalls in 3T MR brain imaging:: A pictorial review
    Schmitz, BL
    Aschoff, AJ
    Hoffmann, MHK
    Grön, G
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2005, 26 (09) : 2229 - 2237
  • [5] 3T neonatal brain and body imaging in a MR compatible incubator
    de Lange, Charlotte
    Nedregaard, Bard
    Lang, Astri
    ACTA RADIOLOGICA, 2013, 54 (04) : 11 - 11
  • [6] 3T MR Imaging of the Shoulder: Is MR Arthrography Necessary?
    Magee, T.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (05)
  • [7] Evaluation of the B0 Field Uniformity On a Compact 3T MR Scanner with High Performance Gradients
    Shu, Y.
    Tao, S.
    Xu, M.
    Laskaris, E.
    Foo, T.
    Weavers, P.
    Trzasko, J.
    Huston, J.
    Bernstein, M.
    MEDICAL PHYSICS, 2017, 44 (06) : 3048 - 3049
  • [8] Normal Pituitary Stalk: High-Resolution MR Imaging at 3T
    Satogami, N.
    Miki, Y.
    Koyama, T.
    Kataoka, M.
    Togashi, K.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2010, 31 (02) : 355 - 359
  • [9] High-Resolution 3T MR Imaging of the Triangular Fibrocartilage Complex
    von Borstel, Donald
    Wang, Michael
    Small, Kirstin
    Nozaki, Taiki
    Yoshioka, Hiroshi
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2017, 16 (01) : 3 - 15
  • [10] In vivo sodium MR imaging of the abdomen at 3T
    James, Judy R.
    Panda, Anshuman
    Lin, Chen
    Dydak, Ulrike
    Dale, Brian M.
    Bansal, Navin
    ABDOMINAL IMAGING, 2015, 40 (07): : 2272 - 2280