Lightweight, compact, and high-performance 3T MR system for imaging the brain and extremities

被引:68
|
作者
Foo, Thomas K. F. [1 ]
Laskaris, Evangelos [1 ]
Vermilyea, Mark [1 ]
Xu, Minfeng [1 ]
Thompson, Paul [1 ]
Conte, Gene [1 ]
Van Epps, Christopher [1 ]
Immer, Christopher [1 ]
Lee, Seung-Kyun [1 ,2 ]
Tan, Ek T. [1 ]
Graziani, Dominic [1 ]
Mathieu, Jean-Baptise [3 ]
Hardy, Christopher J. [1 ]
Schenck, John F. [1 ]
Fiveland, Eric [1 ]
Stautner, Wolfgang [1 ]
Ricci, Justin [1 ]
Piel, Joseph [1 ]
Park, Keith [1 ]
Hua, Yihe [1 ]
Bai, Ye [1 ]
Kagan, Alex [1 ]
Stanley, David [5 ]
Weavers, Paul T. [4 ,5 ]
Gray, Erin [4 ]
Shu, Yunhong [4 ]
Frick, Matthew A. [4 ]
Campeau, Norbert G. [4 ]
Trzasko, Joshua [4 ]
Huston, John, III [4 ]
Bernstein, Matt A. [4 ]
机构
[1] GE Global Res, 1 Res Circle, Niskayuna, NY 12309 USA
[2] Sungkyunkwan Univ, Dept Biomed Engn, Suwon, South Korea
[3] GE Healthcare, Florence, SC USA
[4] Mayo Clin, Dept Radiol, Rochester, MN USA
[5] GE Healthcare, Waukesha, WI USA
关键词
PERIPHERAL-NERVE STIMULATION; TRANSVERSE GRADIENT COILS; CONCOMITANT FIELDS; HEAD; DISTORTION; DIFFUSION; DESIGN; LIMITS; FMRI; BODY;
D O I
10.1002/mrm.27175
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To build and evaluate a small-footprint, lightweight, high-performance 3T MRI scanner for advanced brain imaging with image quality that is equal to or better than conventional whole-body clinical 3T MRI scanners, while achieving substantial reductions in installation costs. Methods: A conduction-cooled magnet was developed that uses less than 12 liters of liquid helium in a gas-charged sealed system, and standard NbTi wire, and weighs approximately 2000 kg. A 42-cm inner-diameter gradient coil with asymmetric transverse axes was developed to provide patient access for head and extremity exams, while minimizing magnet-gradient interactions that adversely affect image quality. The gradient coil was designed to achieve simultaneous operation of 80-mT/m peak gradient amplitude at a slew rate of 700 T/m/s on each gradient axis using readily available 1-MVA gradient drivers. Results: In a comparison of anatomical imaging in 16 patients using T2-weighted 3D fluid-attenuated inversion recovery (FLAIR) between the compact 3T and whole-body 3T, image quality was assessed as equivalent to or better across several metrics. The ability to fully use a high slew rate of 700 T/m/s simultaneously with 80-mT/m maximum gradient amplitude resulted in improvements in image quality across EPI, DWI, and anatomical imaging of the brain. Conclusions: The compact 3T MRI system has been in continuous operation at the Mayo Clinic since March 2016. To date, over 200 patient studies have been completed, including 96 comparison studies with a clinical 3T whole-body MRI. The increased gradient performance has reliably resulted in consistently improved image quality.
引用
收藏
页码:2232 / 2245
页数:14
相关论文
共 50 条
  • [21] 3T MR imaging protocol for characterization of renal masses
    Khatri, Gaurav
    Pedrosa, Ivan M.
    APPLIED RADIOLOGY, 2012, 41 : 22 - 26
  • [22] Partially parallell MR spectroscopic imaging of gliomas at 3T
    Ozturk, Esin
    Banerjee, Suchandrima
    Majumdar, Sharmila
    Nelson, Sarah J.
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 1098 - +
  • [23] Diffusion tensor MR imaging: Fiber tracking at 3T
    Lim, CCT
    Cheng, S
    Zimine, I
    Xu, M
    Sitoh, YY
    Yeo, TT
    Golay, X
    Ng, YK
    Hui, F
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (04) : 121 - 121
  • [24] Identification of the Nervus Intermedius Using 3T MR Imaging
    Burmeister, H. P.
    Baltzer, P. A.
    Dietzel, M.
    Krumbein, I.
    Bitter, T.
    Schrott-Fischer, A.
    Guntinas-Lichius, O.
    Kaiser, W. A.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (03) : 460 - 467
  • [25] An orthogonal shim coil for 3T brain imaging
    Zhou, Jiazheng
    Stockmann, Jason P.
    Arango, Nicolas
    Witzel, Thomas
    Scheffler, Klaus
    Wald, Lawrence L.
    Lin, Fa-Hsuan
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (04) : 1499 - 1511
  • [26] Iterative denoising accelerated 3D SPACE FLAIR sequence for brain MR imaging at 3T
    Eliezer, Michael
    Vaussy, Alexis
    Toupin, Solenn
    Barbe, Remy
    Kannengiesser, Stephan
    Stemmer, Alto
    Houdart, Emmanuel
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2022, 103 (01) : 13 - 20
  • [27] Distortion-Free Imaging: A Double Encoding Method (DIADEM) Combined With Multiband Imaging for Rapid Distortion-Free High-Resolution Diffusion Imaging on a Compact 3T With High-Performance Gradients
    In, Myung-Ho
    Tan, Ek Tsoon
    Trzasko, Joshua D.
    Shu, Yunhong
    Kang, Daehun
    Yarach, Uten
    Tao, Shengzhen
    Gray, Erin M.
    Huston, John, III
    Bernstein, Matt A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2020, 51 (01) : 296 - 310
  • [28] Compact, high-performance hyperspectral imaging systems
    Ziph-Schatzberg, Leah
    Nakanishi, Keith
    LASER FOCUS WORLD, 2015, 51 (06): : 62 - 66
  • [29] Atherosclerosis of middle cerebral artery: Evaluation with high-resolution MR imaging at 3T
    Li, Ming-li
    Xu, Wei-hai
    Song, Lan
    Feng, Feng
    You, Hui
    Ni, Jun
    Gao, Shan
    Cui, Li-ying
    Jin, Zheng-yu
    ATHEROSCLEROSIS, 2009, 204 (02) : 447 - 452
  • [30] Considerations in applying compressed sensing to in vivo phosphorus MR spectroscopic imaging of human brain at 3T
    Gokce Hale Hatay
    Muhammed Yildirim
    Esin Ozturk-Isik
    Medical & Biological Engineering & Computing, 2017, 55 : 1303 - 1315