Automatic method of bone and static tissue removal in neuro CT angiography

被引:0
|
作者
Parrish, T [1 ]
Sen, A [1 ]
Walker, M [1 ]
机构
[1] Northwestern Univ, Chicago, IL 60611 USA
关键词
D O I
10.1118/1.1998456
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this study was to optimize a post‐processing algorithm to eliminate density from bone or other tissues that remain constant during a contrast enhanced CT angiography procedure without compromising the detection of small lesions. Method and Materials: Five patients were scanned using a standard brain CTA protocol: kv=120, mA=300, thickness=2.5 mm, interval=1.25 mm, contrast volume=75 cc's, delay=12s). An identical acquisition was obtained prior to contrast injection. To eliminate movement related errors, the data sets were aligned using a standard motion correction algorithm within SPM2. The pre‐contrast data were used to form a mask based upon intensity thresholds that would capture bone (>200 HU). Additional image processing was used including smoothing and morphologic operations to improve the removal of the bone signal while minimizing the effects to vessel signal. The optimization process involved successive erosion and dilation operations on the mask. A filter was used on the mask to zero pixels between the skull and the external boundaries of the mask. Subtracting the pre‐contrast data from the post‐contrast data was performed to remove static signal. The bone mask was then applied to the difference data to create the final image. The post‐processed CTA data were transferred to a 3D workstation for viewing and qualitative assessment which included the source images and maximum intensity projections. Results: Bone subtraction was successful in all patients without qualitatively significant degradation in contrast‐to noise. The clinical data shows it is possible to remove non‐vascular signal without compromising the visualization of small aneurysms. Conclusion: An automatic method to remove bone density from brain CTA data sets was developed. The method requires a pre‐ and post‐contrast CTA acquisition and thus increases the patients overall radiation exposure though not to significant levels. The automated method will reduce workload and provide non‐biased angiographic data for clinical review. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2110 / 2110
页数:1
相关论文
共 50 条
  • [1] Evaluation of neuro bone removal algorithms for CT angiography
    Fazio, A
    Subramanyan, K
    Lin, Z
    Ciancibello, L
    van Straten, M
    Pohlman, S
    CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 37 - 42
  • [2] Semi-automatic bone removal technique from CT angiography data
    Alyassin, AM
    Avinash, GB
    MEDICAL IMAGING: 2001: IMAGE PROCESSING, PTS 1-3, 2001, 4322 : 1273 - 1283
  • [3] Automatic Bone Removal Dual-Energy CT Angiography for the Evaluation of Intracranial Aneurysms
    Zhang, Long-Jiang
    Wu, Sheng-Yong
    Poon, Colin S.
    Zhao, Yan-E
    Chai, Xue
    Zhou, Chang-Sheng
    Lu, Guang-Ming
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2010, 34 (06) : 816 - 824
  • [4] Automatic vessel extraction by patient motion correction and bone removal in brain CT angiography
    Hong, H
    Lee, H
    Shin, YG
    CARS 2005: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2005, 1281 : 369 - 374
  • [5] Automatic Level Set Based Cerebral Vessel Segmentation and Bone Removal in CT Angiography Data Sets
    Behrens, Stephanie
    PATTERN RECOGNITION, GCPR 2013, 2013, 8142 : 237 - 242
  • [6] Removal of bone in CT angiography by multiscale matched mask bone elimination
    van Andel, H. A. F. Gratama
    Venema, H. W.
    Streekstra, G. J.
    van Straten, M.
    Majoie, C. B. L. M.
    den Heeten, G. J.
    Grimbergen, C. A.
    MEDICAL PHYSICS, 2007, 34 (10) : 3711 - 3723
  • [7] An interactive application for removal of bone information in CT-angiography
    Maksimov, D
    Finkel, F
    Dietz, T
    Diehl, S
    Düber, C
    Rebholz, P
    Hesser, J
    Männer, R
    17TH IEEE SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS, PROCEEDINGS, 2004, : 396 - 401
  • [8] Automatic bone and plaque removal using dual energy CT for head and neck angiography: Feasibility and initial performance evaluation
    Thomas, C.
    Korn, A.
    Krauss, B.
    Ketelsen, D.
    Tsiflikas, I.
    Reimann, A.
    Brodoefel, H.
    Claussen, C. D.
    Kopp, A. F.
    Ernemann, U.
    Heuschmid, M.
    EUROPEAN JOURNAL OF RADIOLOGY, 2010, 76 (01) : 61 - 67
  • [9] Automatic Bone Removal Technique in Whole-Body Dual-Energy CT Angiography: Performance and Image Quality
    Schulz, Boris
    Kuehling, Katharina
    Kromen, Wolfgang
    Siebenhandl, Petra
    Kerl, Matthias Josef
    Vogl, Thomas Josef
    Bauer, Ralf
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) : W646 - W650
  • [10] Value of automatic bone subtraction in cranial CT angiography: comparison of bone-subtracted vs. standard CT angiography in 100 patients
    Morhard, Dominik
    Fink, Christian
    Becker, Christoph
    Reiser, Maximilian F.
    Nikolaou, Konstantin
    EUROPEAN RADIOLOGY, 2008, 18 (05) : 974 - 982