Automatic method of bone and static tissue removal in neuro CT angiography

被引:0
|
作者
Parrish, T [1 ]
Sen, A [1 ]
Walker, M [1 ]
机构
[1] Northwestern Univ, Chicago, IL 60611 USA
关键词
D O I
10.1118/1.1998456
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this study was to optimize a post‐processing algorithm to eliminate density from bone or other tissues that remain constant during a contrast enhanced CT angiography procedure without compromising the detection of small lesions. Method and Materials: Five patients were scanned using a standard brain CTA protocol: kv=120, mA=300, thickness=2.5 mm, interval=1.25 mm, contrast volume=75 cc's, delay=12s). An identical acquisition was obtained prior to contrast injection. To eliminate movement related errors, the data sets were aligned using a standard motion correction algorithm within SPM2. The pre‐contrast data were used to form a mask based upon intensity thresholds that would capture bone (>200 HU). Additional image processing was used including smoothing and morphologic operations to improve the removal of the bone signal while minimizing the effects to vessel signal. The optimization process involved successive erosion and dilation operations on the mask. A filter was used on the mask to zero pixels between the skull and the external boundaries of the mask. Subtracting the pre‐contrast data from the post‐contrast data was performed to remove static signal. The bone mask was then applied to the difference data to create the final image. The post‐processed CTA data were transferred to a 3D workstation for viewing and qualitative assessment which included the source images and maximum intensity projections. Results: Bone subtraction was successful in all patients without qualitatively significant degradation in contrast‐to noise. The clinical data shows it is possible to remove non‐vascular signal without compromising the visualization of small aneurysms. Conclusion: An automatic method to remove bone density from brain CTA data sets was developed. The method requires a pre‐ and post‐contrast CTA acquisition and thus increases the patients overall radiation exposure though not to significant levels. The automated method will reduce workload and provide non‐biased angiographic data for clinical review. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2110 / 2110
页数:1
相关论文
共 50 条
  • [41] Bone subtraction CT angiography for the detection of intracranial aneurysms
    Ramasundara, S.
    Mitchell, P. J.
    Dowling, R. J.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2010, 54 (06) : 526 - 533
  • [42] Flat-detector CT angiography in the evaluation of neuro-Behcet disease
    Alis, D.
    Civcik, C.
    Erol, B. C.
    Kizilkilic, O.
    Kocer, N.
    Islak, C.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2017, 98 (11) : 813 - 815
  • [43] Improved speed of bone removal in CT angiography (CTA) using automated targeted morphological separation: Method and evaluation in CTA of the lower extremity occlusive disease (LEOD)
    Raman, R
    Raman, B
    Hundt, W
    Stucker, D
    Napel, SS
    Rubin, GD
    RADIOLOGY, 2002, 225 : 647 - 647
  • [44] 3D bone subtraction CT angiography for the evaluation of intracranial aneurysms: a comparison study with 2D bone subtraction CT angiography and conventional non-subtracted CT angiography
    Cheng, Bochao
    Cai, Wu
    Sun, Chongran
    Kang, Yan
    Gong, Jianping
    ACTA RADIOLOGICA, 2015, 56 (09) : 1127 - 1134
  • [45] Removal of arterial wall calcifications in CT angiography by local subtraction
    van Straten, M
    Venema, HW
    Streekstra, GJ
    Reekers, JA
    den Heeten, GJ
    Grimbergen, CA
    MEDICAL PHYSICS, 2003, 30 (05) : 761 - 770
  • [46] OUTFLOW REFRESHMENT ANGIOGRAPHY - A BRIGHT BLOOD, BRIGHT STATIC TISSUE TECHNIQUE
    DOYLE, M
    MULLIGAN, SA
    MATSUDA, T
    POHOST, GM
    MAGNETIC RESONANCE IMAGING, 1992, 10 (06) : 887 - 892
  • [47] VESSEL SEGMENTATION BASED ON BONE-TO-BONE ELIMINATION IN BRAIN CT ANGIOGRAPHY
    Chang, Ku-Yaw
    Wu, Yu-Hsun
    Lin, Wei-Lu
    Chen, Shao-Jer
    Chen, Lih-Shyang
    2016 IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS-TAIWAN (ICCE-TW), 2016, : 345 - 346
  • [48] Dual energy CT of peripheral arteries: Effect of automatic bone and plaque removal on image quality and grading of stenoses
    Meyer, B. C.
    Werncke, T.
    Hopfenmueller, W.
    Raatschen, H. J.
    Wolf, K-J.
    Albrecht, T.
    EUROPEAN JOURNAL OF RADIOLOGY, 2008, 68 (03) : 414 - 422
  • [49] Automatic bone removal for abdomen CTA: A clinical review
    Mullick, F
    Avila, RS
    Platt, JF
    Mallya, Y
    Senzig, RF
    Knoplloch, J
    RADIOLOGY, 2002, 225 : 646 - 647
  • [50] Multislice CT coronary angiography: Evaluation of an automatic vessel detection tool
    Dewey, M
    Schnapauff, D
    Laule, M
    Lembcke, A
    Borges, AC
    Rutsch, W
    Hamm, B
    Rogalla, P
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (04): : 478 - 483