Value of automatic bone subtraction in cranial CT angiography: comparison of bone-subtracted vs. standard CT angiography in 100 patients

被引:46
|
作者
Morhard, Dominik [1 ]
Fink, Christian [1 ]
Becker, Christoph [1 ]
Reiser, Maximilian F. [1 ]
Nikolaou, Konstantin [1 ]
机构
[1] Univ Munich, Inst Clin Radiol, D-81377 Munich, Germany
关键词
computed tomography; brain; subtraction technique; digital subtraction angiography;
D O I
10.1007/s00330-008-0855-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Non-contrast-enhanced cranial computed tomography (NECT) and CT angiography (CTA) are the most frequently used modalities in the triage of patients with acute ischemic and hemorrhagic stroke. CTA bone removal can improve the delineation of vasculature closely adjacent to bony structures, which is sometimes limited in standard CTA. The aim of this study was the evaluation of the clinical benefit of bone subtraction(BS) regarding delineation of cerebral vasculature, reading time and depiction of vascular pathologies compared to standard CTA without BS. A total of 100 patients who underwent NECT and supraaortic CTA on a 64-slice CT system were retrospectively included in the study. Bone removal was performed by subtraction of the NECT data from the CTA data using a dedicated work-station. Standard and BS CTA of each patient was reviewed for delineation of cerebral vasculature ( grading scale from 1='' excellent delineation '' to 10='' hardly any delineation ''), reading time and depiction of vascular pathologies ( standardized catalog) by two blinded readers. For BS data sets, the quality of BS was rated by a combination of the criteria complete bone removal, depiction of vascular structures and sufficient quality for diagnostic evaluation. The use of BS significantly reduced reading time from 4.60 min to 3.49 min ( p < 0.001). Performing BS, the quality of vascular delineation of the cerebral arteries, cerebral veins and cavernous segment of the ICA increased significantly as compared to standard CTA ( 1.70 vs. 2.70; 2.60 vs. 4.12; 2.35 vs. 4.40, all p < 0.001). Consensus reading showed 41 pathologies in 35 patients. Diagnosis was missed or wrong overall in 15 cases, with 3 missed aneurysms ( CTA: 2 vs. BS: 1), 8 wrong stenotic findings ( CTA: 3 vs. BS: 5) and 4 missed partial thromboses ( CTA: 2 vs. BS: 2). Performing BS in supraaortic CTA for the evaluation of cerebral vasculature reduces reading time and improves delineation of vessels. Diagnostic accuracy in general is not improved by BS, as the diagnostic accuracy of stenotic vessel alterations is reduced by potential truncation artifacts, but the detection rate of cerebral aneurysms slightly increases.
引用
收藏
页码:974 / 982
页数:9
相关论文
共 50 条
  • [1] Value of automatic bone subtraction in cranial CT angiography: comparison of bone-subtracted vs. standard CT angiography in 100 patients
    Dominik Morhard
    Christian Fink
    Christoph Becker
    Maximilian F. Reiser
    Konstantin Nikolaou
    European Radiology, 2008, 18 : 974 - 982
  • [2] Comparison of bone subtraction CT angiography with standard CT angiography for evaluating circle of Willis in normal dogs
    An, Soyon
    Hwang, Gunha
    Kim, Rakhoon
    Hwang, Tae Sung
    Lee, Hee Chun
    JOURNAL OF VETERINARY SCIENCE, 2023, 24 (05)
  • [3] 3D bone subtraction CT angiography for the evaluation of intracranial aneurysms: a comparison study with 2D bone subtraction CT angiography and conventional non-subtracted CT angiography
    Cheng, Bochao
    Cai, Wu
    Sun, Chongran
    Kang, Yan
    Gong, Jianping
    ACTA RADIOLOGICA, 2015, 56 (09) : 1127 - 1134
  • [4] Dural Carotico-Cavernous Fistula: Pre and Postembolization Appearances of Bone-Subtracted CT Angiography
    Koc, Osman
    Genc, Emine
    Ozturk, Banu
    Genc, Bulent Oguz
    Keskin, Fatih
    Ozbek, Orhan
    TURKISH NEUROSURGERY, 2013, 23 (02) : 249 - 251
  • [5] Clinical evaluation of dual-energy bone removal in CT angiography of the head and neck: comparison with conventional bone-subtraction CT angiography
    Deng, K.
    Liu, C.
    Ma, R.
    Sun, C.
    Wang, X. -m.
    Ma, Z. -t.
    Sun, X. -l.
    CLINICAL RADIOLOGY, 2009, 64 (05) : 534 - 541
  • [6] Bone subtraction CT angiography for the detection of intracranial aneurysms
    Ramasundara, S.
    Mitchell, P. J.
    Dowling, R. J.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2010, 54 (06) : 526 - 533
  • [7] Bone-Subtracted Spinal CT Angiography Using Nonrigid Registration for Better Visualization of Arterial Feeders in Spinal Arteriovenous Fistulas
    Nishii, T.
    Kono, A. K.
    Nishio, M.
    Negi, N.
    Fujita, A.
    Kohmura, E.
    Sugimura, K.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (12) : 2400 - 2406
  • [8] Bone-subtraction CT angiography for the evaluation of intracranial aneurysms
    Tomandl, BF
    Hammen, T
    Klotz, E
    Ditt, H
    Stemper, B
    Lell, M
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2006, 27 (01) : 55 - 59
  • [9] Diagnostic Impact of Bone-Subtraction CT Angiography for Patients with Acute Subarachnoid Hemorrhage
    Aulbach, P.
    Mucha, D.
    Engellandt, K.
    Haedrich, K.
    Kuhn, M.
    von Kummer, R.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (02) : 236 - 243
  • [10] Subtracted 3D CT angiography for evaluation of internal carotid artery aneurysms: Comparison with conventional digital subtraction angiography
    Sakamoto, S
    Kiura, Y
    Shibukawa, M
    Ohba, S
    Arita, K
    Kurisu, K