A comparison of transthoracic impedance using standard defibrillation paddles and self-adhesive defibrillation pads

被引:20
|
作者
Deakin, CD [1 ]
McLaren, RM [1 ]
Petley, GW [1 ]
Clewlow, F [1 ]
Dalrymple-Hay, MJR [1 ]
机构
[1] Southampton Univ Hosp, NHS Trust, Southampton Gen Hosp, Dept Anaesthesia, Southampton SO16 6YD, Hants, England
关键词
defibrillation; transthoracic impedance; defibrillation paddles;
D O I
10.1016/S0300-9572(98)00117-8
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The success of defibrillation is related to transmyocardial current. This current is inversely proportional to transthoracic impedance (TTI). A similar TTI between different pads and paddles is important to deliver a consistent therapeutic dose to all subjects. Failure to do so may result in either insufficient or excessive transmyocardial current leading to a risk of failed defibrillation or tissue damage respectively. Several different types of defibrillation paddles and self-adhesive defibrillation pads are currently available for clinical use but the TTI achieved with each type has not been established. We measured TTI using two types of commonly used paddles and self-adhesive pads to establish whether any significant differences exist between the products. TTI in 40 adult males was measured using defibrillation paddles and self-adhesive defibrillation pads placed in the antero-apical position. Measurements were made using a 30 kHz low amplitude AC current and taken at end-expiration. Mean TTI (Omega) +/- S.D. was 68.2 +/- 16.1 (Hewlett Packard paddles; A), 62.8 +/- 13.2 (Hewlett Packard pads; B), 64.6 +/- 14.3 (PhysioControl paddles, C) and 95.6 +/- 22.3 (PhysioControl pads; D). Significant differences existed between all groups (P < 0.05) except between B and C. Differences in TTI between A, B and C were small and probably of no clinical significance. TTI in group D is significantly larger. Although transmyocardial current is related to TTI, the relationship is complex and differences in TTI alone cannot predict the outcome from defibrillation. (C) 1998 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:43 / 46
页数:4
相关论文
共 50 条
  • [1] External defibrillation in the left lateral position - a comparison of manual paddles with self-adhesive pads
    Dodd, TEL
    Deakin, CD
    Petley, GW
    Clewlow, F
    RESUSCITATION, 2004, 63 (03) : 283 - 286
  • [2] Effect of shaving the chest of hirsute subject on transthoracic impedance to self-adhesive defibrillation electrode pads
    Bissing, JW
    Kerber, RE
    AMERICAN JOURNAL OF CARDIOLOGY, 2000, 86 (05): : 587 - +
  • [3] SELF-ADHESIVE MONITOR DEFIBRILLATION PADS IMPROVE PREHOSPITAL DEFIBRILLATION SUCCESS
    STULTS, KR
    BROWN, DD
    COOLEY, F
    KERBER, RE
    ANNALS OF EMERGENCY MEDICINE, 1987, 16 (08) : 872 - 877
  • [4] SELF-ADHESIVE ELECTRODE PADS FOR DEFIBRILLATION AND CARDIOVERSION
    KERBER, R
    MARTINS, J
    KELLY, K
    FERGUSON, D
    KOUBA, C
    JENSEN, S
    KIESO, R
    MELTON, J
    NEWMAN, B
    PARKE, J
    CIRCULATION, 1983, 68 (04) : 1 - 1
  • [5] SELF-ADHESIVE MONITOR DEFIBRILLATION PADS - PREHOSPITAL USE
    STULTS, KR
    BROWN, DD
    KERBER, RE
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 7 (02) : A241 - A241
  • [6] SELF-ADHESIVE PREAPPLIED ELECTRODE PADS FOR DEFIBRILLATION AND CARDIOVERSION
    KERBER, RE
    MARTINS, JB
    KELLY, KJ
    FERGUSON, DW
    KOUBA, C
    JENSEN, SR
    NEWMAN, B
    PARKE, JD
    KIESO, R
    MELTON, J
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 3 (03) : 815 - 820
  • [7] Transthoracic impedance study with large self-adhesive electrodes in two conventional positions for defibrillation
    Krasteva, Vessela
    Matveev, Mikhail
    Mudrov, Nikolay
    Prokopova, Rada
    PHYSIOLOGICAL MEASUREMENT, 2006, 27 (10) : 1009 - 1022
  • [9] Self-adhesive pads in defibrillation or cardioversion: risks due to unfamiliarity and recommendations
    Chung, Hansol
    WORLD JOURNAL OF EMERGENCY MEDICINE, 2024, 15 (01) : 64 - 66
  • [10] OPTIMAL SIZE OF SELF-ADHESIVE PREAPPLIED ELECTRODE PADS IN PEDIATRIC DEFIBRILLATION
    SAMSON, RA
    ATKINS, DL
    KERBER, RE
    AMERICAN JOURNAL OF CARDIOLOGY, 1995, 75 (07): : 544 - 545