Dual-energy x-ray approach for object/energy-specific attenuation coefficient correction in single-photon emission computed tomography: effects of contrast agent

被引:5
|
作者
Goh, Kheng Lim [1 ]
Liew, Soo Chin [2 ,3 ]
机构
[1] Newcastle Univ, Singapore Campus, Singapore, Singapore
[2] Natl Univ Singapore, Ctr Remote Imaging Sensing & Proc, Singapore, Singapore
[3] Natl Univ Singapore, Dept Phys, Singapore, Singapore
关键词
dual-energy computed tomography; basis material decomposition; basis material coefficients; radiographic contrast agent; systematic errors; attenuation correction; DEPENDENT SYSTEMATIC-ERRORS; CT APPLICATIONS; IMAGES;
D O I
10.1117/1.JMI.8.5.052106
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the influence of radiographic contrast agent on the accuracy of the photon counts arising from the emission of gamma rays of radionuclides in single-photon emission computed tomography (SPECT), when dual-energy x-ray CT (DXCT) is employed for providing object/energy-specific attenuation coefficient correction in SPECT. Approach: Computer simulation was performed for three transmission CT approaches, namely, the conventional (single kVp, unimodal spectrum) x-ray CT, DXCT (single kVp, bimodal spectrum) with basis material decomposition (BMD), and DXCT with BMD followed by basis material coefficients transformation (BMT), to study the effects of these approaches on the accuracy of the photon counts from the SPECT image of a thorax-like phantom. Results: All three CT approaches revealed that the error in the counts was both photon energy and iodine concentration-dependent. Differences in the trending increase/decrease in the errors with the respective increase in iodine concentration and photon energy were observed among the three CT approaches. Of the three, the BMT/SPECT approach resulted in the smallest error in the concentration of radionuclides measured, especially in the contrast agent-filled region, and the optimal level depended on the iodine concentration and photon energy. Conclusion: With a judicious choice of the basis materials and photon energy, it may be possible to take advantage of the benefits of the BMT method to mitigate the accuracy problem in DXCT for quantitative SPECT imaging. (C) 2021 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:18
相关论文
共 50 条
  • [31] The accuracy of peripheral skeletal assessment at the radius in estimating femoral bone density as measured by dual-energy X-ray absorptiometry: a comparative study of single-photon absorptiometry and computed tomography
    Boonen, S
    Cheng, X
    Nicholson, PHF
    Verbeke, G
    Broos, P
    Dequeker, J
    JOURNAL OF INTERNAL MEDICINE, 1997, 242 (04) : 323 - 328
  • [32] Combination of Single-Photon Emission and X-Ray Computed Tomography to visualize aerosol deposition in pleated filter
    Gervais, P. -C.
    Poussier, S.
    Bardin-Monnier, N.
    Karcher, G.
    Thomas, D.
    SEPARATION AND PURIFICATION TECHNOLOGY, 2014, 126 : 52 - 61
  • [33] A generalized simultaneous algebraic reconstruction technique (GSART) for dual-energy X-ray computed tomography
    Lee, Donghyeon
    Yun, Sungho
    Soh, Jeongtae
    Lim, Sunho
    Kim, Hyoyi
    Cho, Seungryong
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2022, 30 (03) : 549 - 566
  • [34] Experimental feasibility of dual-energy computed tomography based on the Thomson scattering X-ray source
    Chi, Zhijun
    Du, Yingchao
    Yan, Lixin
    Wang, Dong
    Zhang, Hongze
    Huang, Wenhui
    Tang, Chuanxiang
    JOURNAL OF SYNCHROTRON RADIATION, 2018, 25 : 1797 - 1802
  • [35] Energy Window and Contrast Optimization for Single-photon Emission Computed Tomography Bremsstrahlung Imaging with Yttrium-90
    Bouzekraoui, Youssef
    Bentayeb, Farida
    Asmi, Hicham
    Bonutti, Faustino
    INDIAN JOURNAL OF NUCLEAR MEDICINE, 2019, 34 (02): : 125 - 128
  • [36] Dual-energy X-ray computed tomography for void detection in fiber-reinforced composites
    Suzuki, Yasuhito
    Cousins, Dylan S.
    Dorgan, John R.
    Stebner, Aaron P.
    Kappes, Branden B.
    JOURNAL OF COMPOSITE MATERIALS, 2019, 53 (17) : 2349 - 2359
  • [37] Comparison of the dual-energy window method and the triple-energy window method for quantitative single photon emission computed tomography
    Ito, Y.
    Kuniyoshi, M.
    Suetake, M.
    Mochizuki, K.
    Matsumoto, K.
    Endo, K.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S647 - S647
  • [38] Embossed x-ray computed tomography utilizing pixel-shifted dual-energy subtraction
    Ito, Kazuki
    Sato, Eiichi
    Oda, Yasuyuki
    Moriyama, Hodaka
    Hagiwara, Osahiko
    Enomoto, Toshiyuki
    Yoshida, Sohei
    Watanabe, Manabu
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2024, 95 (07):
  • [39] Dual-Energy X-Ray Performs as Well as Clinical Computed Tomography for the Measurement of Visceral Fat
    Micklesfield, Lisa K.
    Goedecke, Julia H.
    Punyanitya, Mark
    Wilson, Kevin E.
    Kelly, Thomas L.
    OBESITY, 2012, 20 (05) : 1109 - 1114
  • [40] Dual-energy X-ray computed tomography system using an LSO-MPPC detector
    Sato, Eiichi
    Oda, Yasuyuki
    Yamaguchi, Satoshi
    Hagiwara, Osahiko
    Matsukiyo, Hiroshi
    Osawa, Akihiro
    Enomoto, Toshiyuki
    Watanabe, Manabu
    Kusachi, Shinya
    MEDICAL APPLICATIONS OF RADIATION DETECTORS IV, 2014, 9214