Dual-energy x-ray approach for object/energy-specific attenuation coefficient correction in single-photon emission computed tomography: effects of contrast agent

被引:5
|
作者
Goh, Kheng Lim [1 ]
Liew, Soo Chin [2 ,3 ]
机构
[1] Newcastle Univ, Singapore Campus, Singapore, Singapore
[2] Natl Univ Singapore, Ctr Remote Imaging Sensing & Proc, Singapore, Singapore
[3] Natl Univ Singapore, Dept Phys, Singapore, Singapore
关键词
dual-energy computed tomography; basis material decomposition; basis material coefficients; radiographic contrast agent; systematic errors; attenuation correction; DEPENDENT SYSTEMATIC-ERRORS; CT APPLICATIONS; IMAGES;
D O I
10.1117/1.JMI.8.5.052106
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the influence of radiographic contrast agent on the accuracy of the photon counts arising from the emission of gamma rays of radionuclides in single-photon emission computed tomography (SPECT), when dual-energy x-ray CT (DXCT) is employed for providing object/energy-specific attenuation coefficient correction in SPECT. Approach: Computer simulation was performed for three transmission CT approaches, namely, the conventional (single kVp, unimodal spectrum) x-ray CT, DXCT (single kVp, bimodal spectrum) with basis material decomposition (BMD), and DXCT with BMD followed by basis material coefficients transformation (BMT), to study the effects of these approaches on the accuracy of the photon counts from the SPECT image of a thorax-like phantom. Results: All three CT approaches revealed that the error in the counts was both photon energy and iodine concentration-dependent. Differences in the trending increase/decrease in the errors with the respective increase in iodine concentration and photon energy were observed among the three CT approaches. Of the three, the BMT/SPECT approach resulted in the smallest error in the concentration of radionuclides measured, especially in the contrast agent-filled region, and the optimal level depended on the iodine concentration and photon energy. Conclusion: With a judicious choice of the basis materials and photon energy, it may be possible to take advantage of the benefits of the BMT method to mitigate the accuracy problem in DXCT for quantitative SPECT imaging. (C) 2021 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:18
相关论文
共 50 条
  • [21] Dual-energy X-ray analysis using synchrotron computed tomography at 35 and 60 keV for the estimation of photon interaction coefficients describing attenuation and energy absorption
    Midgley, Stewart
    Schleich, Nanette
    JOURNAL OF SYNCHROTRON RADIATION, 2015, 22 : 807 - 818
  • [22] Chronic thromboembolic pulmonary hypertension: Comparison of dual-energy computed tomography and single photon emission computed tomography in canines
    Tang, Chun Xiang
    Yang, Gui Fen
    Schoepf, U. Joseph
    Han, Zong Hong
    Qi, Li
    Zhao, Yan E.
    Wu, Jiang
    Zhou, Chang Sheng
    Zhu, Hong
    Stubenrauch, Andrew C.
    Mangold, Stefanie
    Zhang, Long Jiang
    Lu, Guang Ming
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (02) : 498 - 506
  • [23] Discrepancy between Dual-Energy Computed Tomography Lung Perfusion Blood Volume and Lung Perfusion Single-Photon Emission Computed Tomography/Computed Tomography Images in Pulmonary Embolism
    Koike, Hirofumi
    Sueyoshi, Eijun
    Nagayama, Hiroki
    Ashizawa, Kazuto
    Sakamoto, Ichiro
    Uetani, Masataka
    Kudo, Takashi
    Ikeda, Satoshi
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2014, 189 (12) : E71 - E72
  • [24] Correlations of dual-energy X-ray absorptiometry, quantitative computed tomography, and single photon absorptiometry with spinal and non-spinal fractures
    Lafferty, FW
    Rowland, DY
    OSTEOPOROSIS INTERNATIONAL, 1996, 6 (05) : 407 - 415
  • [25] Prospective value of perfusion and X-ray attenuation imaging with single-photon emission and transmission computed tomography in acute cerebral ischemia
    Barthel, H
    Hesse, S
    Dannenberg, C
    Rössler, A
    Schneider, D
    Knapp, WH
    Dietrich, J
    Berrouschot, A
    STROKE, 2001, 32 (07) : 1588 - 1597
  • [26] Lung Perfused Blood Volume Images With Dual-Energy Computed Tomography for Chronic Thromboembolic Pulmonary Hypertension: Correlation to Scintigraphy With Single-Photon Emission Computed Tomography
    Nakazawa, Tetsuro
    Watanabe, Yoshiyuki
    Hori, Yoshiro
    Kiso, Keisuke
    Higashi, Masahiro
    Itoh, Toshihide
    Naito, Hiroaki
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2011, 35 (05) : 590 - 595
  • [27] A Comparison of Dual-energy X-ray Absorptiometry and Lumbar Computed Tomography Hounsfield Units
    Aynaszyan, Stephan
    Devia, Luis G.
    Parry, Matthew W.
    Badve, Siddharth
    DelSole, Edward M.
    CLINICAL SPINE SURGERY, 2023, 36 (08): : E369 - E374
  • [28] Pilot study for comparative assessment of dual-energy computed tomography and single-photon emission computed tomography V/Q scanning for lung perfusion evaluation in infants
    Ramirez-Suarez, Karen, I
    Barrera, Christian A.
    Otero, Hansel J.
    Biko, David M.
    States, Lisa J.
    Servaes, Sabah
    Zhu, Xiaowei
    Davis, James C.
    Piccione, Joseph
    Rapp, Jordan B.
    PEDIATRIC PULMONOLOGY, 2022, 57 (03) : 702 - 710
  • [29] Exploring silver as a contrast agent for contrast-enhanced dual-energy X-ray breast imaging
    Karunamuni, R.
    Tsourkas, A.
    Maidment, A. D. A.
    BRITISH JOURNAL OF RADIOLOGY, 2014, 87 (1041):
  • [30] DUAL-ENERGY X-RAY ABSORPTIOMETRY VERSUS SINGLE PHOTON-ABSORPTIOMETRY OF THE RADIUS
    WEINSTEIN, RS
    NEW, KD
    SAPPINGTON, LJ
    CALCIFIED TISSUE INTERNATIONAL, 1991, 49 (05) : 313 - 316