Dual-energy x-ray approach for object/energy-specific attenuation coefficient correction in single-photon emission computed tomography: effects of contrast agent

被引:5
|
作者
Goh, Kheng Lim [1 ]
Liew, Soo Chin [2 ,3 ]
机构
[1] Newcastle Univ, Singapore Campus, Singapore, Singapore
[2] Natl Univ Singapore, Ctr Remote Imaging Sensing & Proc, Singapore, Singapore
[3] Natl Univ Singapore, Dept Phys, Singapore, Singapore
关键词
dual-energy computed tomography; basis material decomposition; basis material coefficients; radiographic contrast agent; systematic errors; attenuation correction; DEPENDENT SYSTEMATIC-ERRORS; CT APPLICATIONS; IMAGES;
D O I
10.1117/1.JMI.8.5.052106
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the influence of radiographic contrast agent on the accuracy of the photon counts arising from the emission of gamma rays of radionuclides in single-photon emission computed tomography (SPECT), when dual-energy x-ray CT (DXCT) is employed for providing object/energy-specific attenuation coefficient correction in SPECT. Approach: Computer simulation was performed for three transmission CT approaches, namely, the conventional (single kVp, unimodal spectrum) x-ray CT, DXCT (single kVp, bimodal spectrum) with basis material decomposition (BMD), and DXCT with BMD followed by basis material coefficients transformation (BMT), to study the effects of these approaches on the accuracy of the photon counts from the SPECT image of a thorax-like phantom. Results: All three CT approaches revealed that the error in the counts was both photon energy and iodine concentration-dependent. Differences in the trending increase/decrease in the errors with the respective increase in iodine concentration and photon energy were observed among the three CT approaches. Of the three, the BMT/SPECT approach resulted in the smallest error in the concentration of radionuclides measured, especially in the contrast agent-filled region, and the optimal level depended on the iodine concentration and photon energy. Conclusion: With a judicious choice of the basis materials and photon energy, it may be possible to take advantage of the benefits of the BMT method to mitigate the accuracy problem in DXCT for quantitative SPECT imaging. (C) 2021 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:18
相关论文
共 50 条
  • [11] Bone densitometry of the forearm: Comparison of single-photon and dual-energy X-ray absorptiometry
    Eckert, P
    Casez, JP
    Thiebaud, D
    Schnyder, P
    Burckhardt, P
    BONE, 1996, 18 (06) : 575 - 579
  • [12] DUAL-ENERGY X-RAY ABSORPTIOMETRY OF THE CALCANEUS - COMPARISON WITH VERTEBRAL DUAL-ENERGY X-RAY ABSORPTIOMETRY AND QUANTITATIVE COMPUTED-TOMOGRAPHY
    LAVALJEANTET, AM
    BERGOT, C
    WILLIAMS, M
    DAVIDSON, K
    LAVALJEANTET, M
    CALCIFIED TISSUE INTERNATIONAL, 1995, 56 (01) : 14 - 18
  • [13] Verification of in-phantom x-ray energy spectra in dual-energy computed tomography
    Ishii, T.
    Numamoto, H.
    Hirai, Y.
    Koyama, S.
    Kawano, M.
    Ohashi, K.
    Proceedings of the 20th EGS Users' Meeting in Japan, 2013, : 9 - 14
  • [14] Comparison of single photon absorptiometry with dual-energy x-ray absorptiometry and quantitative computed tomography in postmenopausal females.
    Bagni, B
    Pansini, F
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 1259 - 1259
  • [15] Dual-energy X-ray backscatter imaging based on attenuation coefficient decomposition
    Wu, Ruohan
    Yang, Yong
    Cao, Zihao
    Wu, Jiping
    Yan, Han
    Liu, Zhengzheng
    RADIATION PHYSICS AND CHEMISTRY, 2025, 232
  • [16] Spectral Properties of Abdominal Tissues on Dual-energy Computed Tomography and the Effects of Contrast Agent
    Kreul, Diana A.
    Kubik-Huch, Rahel A.
    Froehlich, John
    Thali, Michael J.
    Niemann, Tilo
    IN VIVO, 2021, 35 (06): : 3277 - 3287
  • [17] Preclinical Dual-Energy X-ray Computed Tomography Through Differential Filtration
    Taschereau, Richard
    Chatziioannou, Arion F.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3954 - 3957
  • [18] Quantification of a silver contrast agent in dual-energy breast x-ray imaging
    Karunamuni, Roshan
    Maidment, Andrew D. A.
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [19] Study on dual-energy X-ray computed tomography using synchrotron radiation
    Tsunoo, T
    Torikoshi, A
    Endo, M
    Natsuhori, A
    Kakizaki, T
    Yamada, N
    Itoh, N
    Uesugi, K
    Yagi, N
    SYNCHROTRON RADIATION INSTRUMENTATION, 2004, 705 : 1368 - 1371
  • [20] Dual-energy computed tomography imaging with megavoltage and kilovoltage X-ray spectra
    Jadick, Giavanna
    Schlafly, Geneva
    La Riviere, Patrick J.
    JOURNAL OF MEDICAL IMAGING, 2024, 11 (02)