Optimization of a neutron image plate detector with low γ-sensitivity

被引:12
|
作者
Masalovich, S
Ioffe, A
Schlapp, M
von Seggern, H
Küssel, E
Brückel, T
机构
[1] Tech Univ Munich, ZWE FRM 2, D-85747 Garching, Germany
[2] Forschungszentrum Julich GmbH, Inst Festkorperforsch, D-52425 Julich, Germany
[3] TH Darmstadt, Inst Elect Mat, D-64287 Darmstadt, Germany
关键词
neutron detector; image plate; detector efficiency; pixelated detector;
D O I
10.1016/j.nima.2004.10.002
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Recent experimental studies on new materials (storage phosphors and neutron converter) to be used in a low gamma-sensitive neutron image plate detector have been performed at the Research Center Julich and Darmstadt University of Technology. It was shown that a mixture LiF + KCl: Eu2+ (or KBr:Eu2+) features a higher neutron/gamma signal ratio compared to BaFBr:Eu2+ mixed with Gd as in commercially available neutron image plates. However, the smaller neutron capture cross-section of Li-6 in comparison with Gd requires the use of significantly thicker recording layers. This article presents the results of numerical estimations for the performance of such a detector. The use of image plates with a thick recording layer and a regular cell structure allowing for the increase in spatial resolution (pixelated image plate) is discussed. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:236 / 249
页数:14
相关论文
共 50 条
  • [31] Application of the microhole and strip plate detector for neutron detection
    Veloso, JFCA
    Amaro, F
    dos Santos, JMF
    Mir, JA
    Derbyshire, GE
    Stephenson, R
    Rhodes, NJ
    Schooneveld, EM
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) : 2104 - 2109
  • [32] A PARALLEL PLATE B-10 NEUTRON DETECTOR
    TODD, JH
    WESTON, LW
    DIXON, GJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 219 (03): : 575 - 581
  • [33] BORON TRIFLUORIDE NEUTRON DETECTOR FOR LOW NEUTRON INTENSITIES
    SEGRE, E
    WIEGAND, C
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1947, 18 (02): : 86 - 89
  • [34] A LARGE IMAGE-PLATE DETECTOR FOR NEUTRONS
    CIPRIANI, F
    CASTAGNA, JC
    LEHMANN, MS
    WILKINSON, C
    PHYSICA B, 1995, 213 : 975 - 977
  • [35] Neutron radiography of thick hydrogeneous materials with use of an imaging plate neutron detector
    Inazawa City Hospital, Aichi, Japan
    Nucl Instrum Methods Phys Res Sect A, 1 (123-125):
  • [36] Neutron diffractometer for bio-crystallography (BIX) with an imaging plate neutron detector
    Niimura, N
    NEUTRONS IN BIOLOGY, 1996, 64 : 415 - 422
  • [37] Neutron radiography of thick hydrogenous materials with use of an imaging plate neutron detector
    Kato, K
    Matsumoto, G
    Karasawa, Y
    Niimura, N
    Matsubayashi, M
    Tsuruno, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 377 (01): : 123 - 125
  • [38] 3He Alternative Technologies: 1. Application of Neutron Image Plate Detector for Powder Diffractometry
    Shaikh, A. M.
    Krishna, P. S. R.
    Shinde, A. B.
    SOLID STATE PHYSICS, PTS 1 AND 2, 2012, 1447 : 485 - 486
  • [39] Absolute neutron sensitivity of a GSO(Ce) scintillation detector
    Uozumi, Y
    Anami, K
    Nohtomi, A
    Sakae, T
    Matoba, M
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1997, 34 (01) : 80 - 82
  • [40] Neutron sensitivity of the endcap RPC modules in Belle detector
    Abe, K
    Hoshi, Y
    Nagamine, T
    Neichi, K
    Onodera, K
    Takahashi, T
    Yamaguchi, A
    Yuta, H
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 171 - 175