Optimization of a neutron image plate detector with low γ-sensitivity

被引:12
|
作者
Masalovich, S
Ioffe, A
Schlapp, M
von Seggern, H
Küssel, E
Brückel, T
机构
[1] Tech Univ Munich, ZWE FRM 2, D-85747 Garching, Germany
[2] Forschungszentrum Julich GmbH, Inst Festkorperforsch, D-52425 Julich, Germany
[3] TH Darmstadt, Inst Elect Mat, D-64287 Darmstadt, Germany
关键词
neutron detector; image plate; detector efficiency; pixelated detector;
D O I
10.1016/j.nima.2004.10.002
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Recent experimental studies on new materials (storage phosphors and neutron converter) to be used in a low gamma-sensitive neutron image plate detector have been performed at the Research Center Julich and Darmstadt University of Technology. It was shown that a mixture LiF + KCl: Eu2+ (or KBr:Eu2+) features a higher neutron/gamma signal ratio compared to BaFBr:Eu2+ mixed with Gd as in commercially available neutron image plates. However, the smaller neutron capture cross-section of Li-6 in comparison with Gd requires the use of significantly thicker recording layers. This article presents the results of numerical estimations for the performance of such a detector. The use of image plates with a thick recording layer and a regular cell structure allowing for the increase in spatial resolution (pixelated image plate) is discussed. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:236 / 249
页数:14
相关论文
共 50 条
  • [21] Optimization of neutron imaging plate
    Haga, YK
    Neriishi, K
    Takahashi, K
    Niimura, N
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 487 (03): : 504 - 510
  • [22] A new fast and large area neutron detector using a novel image plate readout technique
    Schillinger, B
    Baumann, J
    Gebele, H
    Schaetzing, R
    Schaller, H
    Schuster, M
    APPLIED RADIATION AND ISOTOPES, 2004, 61 (04) : 451 - 454
  • [23] DETECTOR FOR LOW NEUTRON FLUXES
    SOKOLOVA, ZY
    CHERNYAE.VB
    SOVIET ATOMIC ENERGY, 1968, 25 (03): : 1018 - &
  • [24] Neutron stress measurement using neutron image plate
    Sasaki, T
    Minakawa, N
    Morii, Y
    Niimura, N
    Hirose, Y
    RESIDUAL STRESSES VII, PROCEEDINGS, 2005, 490-491 : 229 - 233
  • [25] BORON-LOADED NEUTRON DETECTOR WITH VERY LOW GAMMA-RAY SENSITIVITY
    JACKSON, HE
    THOMAS, GE
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1965, 36 (04): : 419 - +
  • [26] High-Sensitivity Activation Neutron Detector
    Antropov, S. Y.
    Ermilov, A. P.
    Measurement Techniques (English translation of Izmeritel'naya Tekhnika), 38 (02):
  • [27] THE PHOTON SENSITIVITY OF A MODERATED ACTIVATION NEUTRON DETECTOR
    MCGINLEY, PH
    MEDICAL PHYSICS, 1986, 13 (05) : 700 - 702
  • [28] Sensitivity of a new-developed neutron detector
    PENG Tai-Ping1
    1 2Institute of Electronic Engineering
    Nuclear Science and Techniques, 2005, (01) : 40 - 42
  • [29] HIGH-SENSITIVITY ACTIVATION NEUTRON DETECTOR
    ANTROPOV, SY
    ERMILOV, AP
    MEASUREMENT TECHNIQUES USSR, 1995, 38 (02): : 227 - 228
  • [30] Sensitivity of a new-developed neutron detector
    Peng, Tai-Ping
    Zhu, Xue-Bin
    Yang, Hong-Qiong
    Yang, Jian-Lun
    Yang, Gao-Zhao
    Li, Lin-Bo
    Song, Xian-Cai
    Nuclear Science and Techniques/Hewuli, 2005, 16 (01): : 40 - 42