Comparison of the I-Gel and the Laryngeal Mask Airway Proseal during General Anesthesia: A Systematic Review and Meta-Analysis

被引:37
|
作者
Park, Sun Kyung [1 ]
Choi, Geun Joo [2 ]
Choi, Yun Suk [1 ]
Ahn, Eun Jin [3 ]
Kang, Hyun [2 ]
机构
[1] Jeju Natl Univ, Dept Anesthesiol & Pain Med, Coll Med, Jeju, South Korea
[2] Chung Ang Univ, Coll Med, Dept Anesthesiol & Pain Med, Seoul 156756, South Korea
[3] SungKyunKwan Univ Hosp, Dept Anesthesiol & Pain Med, Seoul, South Korea
来源
PLOS ONE | 2015年 / 10卷 / 03期
关键词
SUPRAGLOTTIC AIRWAY; LMA; CROSSOVER; PRESSURE;
D O I
10.1371/journal.pone.0119469
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objectives Conflicting results have been reported for the i-gel and the laryngeal mask airway proseal (LMA-P) during general anesthesia. The objective of the current investigation was to compare the efficacy and safety of the i-gel vs. the LMA-P during general anesthesia. Methods Two authors performed searches of MEDLINE, EMBASE, CENTRAL, and Google Scholar to identify randomized clinical trials that compared the LMA-P with the i-gel during general anesthesia. A meta -analysis was performed using both random and fixed-effect models. Publication bias was evaluated using Begg's funnel plot and Egger's linear regression test. Results Twelve randomized clinical trials met the eligibility criteria. There were no significant differences in insertion success rate at the first attempt (risk ratio [RR] 1.01, 95% confidence interval [CI] 0.97, 1.06), ease of insertion (RR 1.14, 95% CI 0.93, 1.39), oropharyngeal leak pressure (OLP) (MD -1.98, 95% CI -5.41, 1.45), quality of fiberoptic view (RR 1.00, 95% CI 0.91, 1.10) and success rate of gastric tube insertion (RR 1.07, 95% CI 0.98, 1.18) between the i-gel and the LMA-P, respectively. The i-gel had a shorter insertion time than the LMA-P (MD -3.99, 95% CI -7.13, -0.84) and a lower incidence of blood staining on the device (RR 0.26, 95% CI 0.14, 0.49), sore throat (RR 0.28, 95% CI 0.15, 0.50) and dysphagia (RR 0.27, 95% CI 0.10, 0.74). Conclusions Both devices were comparable in ease of insertion to insert and both had sufficient OLP to provide a reliable airway. Only a few minor complications were reported. The i-gel was found to have fewer complications (blood staining, sore throat, dysphagia) than the LMA-P and offers certain advantages over the LMA-P in adults under general anesthesia.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] The ProSeal Laryngeal Mask Airway is more effective than the LMA-Classic in pediatric anesthesia: a meta-analysis
    Zhang, Xiaolong
    Chen, Minghui
    Li, Quan
    JOURNAL OF CLINICAL ANESTHESIA, 2012, 24 (08) : 639 - 646
  • [42] Comparison of Laryngeal Mask Supreme™ and i-gel™ in simulated difficult airway in anesthetized patients
    Theiler, L.
    Kleine-Brueggeney, M.
    Urwyler, N.
    Luyet, C.
    Kaiser, D.
    Greif, R.
    SWISS MEDICAL WEEKLY, 2008, 138 (41-42) : 7S - 7S
  • [43] Comparison of Frequency of Complications of i-Gel and Laryngeal Mask Airway Supreme™ in Laparoscopic Cholecystectomy
    Ali, Kashif
    Kumar, Ravi
    Ali, Abid
    Ali, Pervaiz
    Alam, M. Aneeque
    Kumar, Kelash
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2021, 15 (12): : 3180 - 3182
  • [44] Evaluation of i-gel™ airway in children: a meta-analysis
    Maitra, Souvik
    Baidya, Dalim K.
    Bhattacharjee, Sulagna
    Khanna, Puneet
    PEDIATRIC ANESTHESIA, 2014, 24 (10) : 1072 - 1079
  • [45] Comparison of Baska mask airway and i-gel for ease of insertion and hemodynamic stability in patients undergoing general anesthesia
    Gupta, Ankita
    Rastogi, Kapil
    Khan, Aamir Laique
    Pathak, Amitesh
    Shahid, Razi
    ANAESTHESIA PAIN & INTENSIVE CARE, 2025, 29 (01) : 70 - 76
  • [46] I-GEL LARYNGEAL MASK AIRWAY: AN EFFECTIVE SUPRAGLOTTIC AIRWAY FOR SPONTANEOUS BREATHING GENERAL ANESTHESIA IN NON-INTUBATED UNIPORTAL THORACOSCOPIC RESECTION
    Jiang, Shan
    Yin, Fei
    Wang, Mei-qing
    Cui, Yan
    Sun, Yang
    ACTA MEDICA MEDITERRANEA, 2019, 35 (06): : 3127 - 3130
  • [47] To Compare the Frequency of Postoperative Sore Throat with I-Gel Versus Laryngeal Mask Airway in patients undergoing General Surgery under General Anesthesia
    Kamal, Muhammad Junaid Ahmed
    Zaheer, Baber
    Durrani, Naveed Ahmed
    Ahmad, Khaleel
    Tabassam, Sumara
    Rashid, Zakariya
    Nishat, Mufassar
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2021, 15 (12): : 3232 - 3235
  • [48] Comparative efficacy and safety of the Ambu® AuraOnce™ laryngeal mask airway during general anaesthesia in adults: a systematic review and meta-analysis
    Baidya, D. K.
    Chandralekha
    Darlong, V.
    Pandey, R.
    Maitra, S.
    Khanna, P.
    ANAESTHESIA, 2014, 69 (09) : 1023 - 1032
  • [49] Comparison of I-gel with Classic Laryngeal Mask Airway Regarding the Ease of Use and Clinical Performance
    Ari, Dilek Erdogan
    Ar, Arzu Yildirim
    Karip, Ceren Sanli
    Siyahkoc, Incifer
    Arslan, Ahmet Hakan
    Akgun, Fatma Nur
    TURKISH JOURNAL OF ANAESTHESIOLOGY AND REANIMATION, 2015, 43 (05) : 299 - 303
  • [50] Comparison of endotracheal intubation, laryngeal mask airway, and I-gel in children undergoing strabismus surgery
    Allahyari, Elaheh
    Azimi, Ali
    Zarei, Hamed
    Bamdad, Shahram
    JOURNAL OF RESEARCH IN MEDICAL SCIENCES, 2021, 26 (01):