Comparison of the I-Gel and the Laryngeal Mask Airway Proseal during General Anesthesia: A Systematic Review and Meta-Analysis

被引:37
|
作者
Park, Sun Kyung [1 ]
Choi, Geun Joo [2 ]
Choi, Yun Suk [1 ]
Ahn, Eun Jin [3 ]
Kang, Hyun [2 ]
机构
[1] Jeju Natl Univ, Dept Anesthesiol & Pain Med, Coll Med, Jeju, South Korea
[2] Chung Ang Univ, Coll Med, Dept Anesthesiol & Pain Med, Seoul 156756, South Korea
[3] SungKyunKwan Univ Hosp, Dept Anesthesiol & Pain Med, Seoul, South Korea
来源
PLOS ONE | 2015年 / 10卷 / 03期
关键词
SUPRAGLOTTIC AIRWAY; LMA; CROSSOVER; PRESSURE;
D O I
10.1371/journal.pone.0119469
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objectives Conflicting results have been reported for the i-gel and the laryngeal mask airway proseal (LMA-P) during general anesthesia. The objective of the current investigation was to compare the efficacy and safety of the i-gel vs. the LMA-P during general anesthesia. Methods Two authors performed searches of MEDLINE, EMBASE, CENTRAL, and Google Scholar to identify randomized clinical trials that compared the LMA-P with the i-gel during general anesthesia. A meta -analysis was performed using both random and fixed-effect models. Publication bias was evaluated using Begg's funnel plot and Egger's linear regression test. Results Twelve randomized clinical trials met the eligibility criteria. There were no significant differences in insertion success rate at the first attempt (risk ratio [RR] 1.01, 95% confidence interval [CI] 0.97, 1.06), ease of insertion (RR 1.14, 95% CI 0.93, 1.39), oropharyngeal leak pressure (OLP) (MD -1.98, 95% CI -5.41, 1.45), quality of fiberoptic view (RR 1.00, 95% CI 0.91, 1.10) and success rate of gastric tube insertion (RR 1.07, 95% CI 0.98, 1.18) between the i-gel and the LMA-P, respectively. The i-gel had a shorter insertion time than the LMA-P (MD -3.99, 95% CI -7.13, -0.84) and a lower incidence of blood staining on the device (RR 0.26, 95% CI 0.14, 0.49), sore throat (RR 0.28, 95% CI 0.15, 0.50) and dysphagia (RR 0.27, 95% CI 0.10, 0.74). Conclusions Both devices were comparable in ease of insertion to insert and both had sufficient OLP to provide a reliable airway. Only a few minor complications were reported. The i-gel was found to have fewer complications (blood staining, sore throat, dysphagia) than the LMA-P and offers certain advantages over the LMA-P in adults under general anesthesia.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Comparison of remifentanil EC50 for facilitating i-gel and laryngeal mask airway insertion with propofol anesthesia
    Choi, Jong Bum
    Kwak, Hyun Jeong
    Lee, Kyung Cheon
    Lee, Se Ryeon
    Lee, Sook Young
    Kim, Jong Yeop
    JOURNAL OF ANESTHESIA, 2016, 30 (03) : 377 - 383
  • [32] Lubrication of the i-gel supraglottic airway and the classic laryngeal mask airway
    Chapman, D.
    ANAESTHESIA, 2010, 65 (01) : 89 - 89
  • [33] Evaluating the Clinical Performance and Upper Airway Morbidity of I-Gel and its Comparison with Proseal Laryngeal Mask Airway-A Randomised Controlled Trial
    Asha, H. L.
    Nagaraj, M. C.
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2020, 14 (04) : UC1 - UC5
  • [34] Comparison of remifentanil EC50 for facilitating i-gel and laryngeal mask airway insertion with propofol anesthesia
    Jong Bum Choi
    Hyun Jeong Kwak
    Kyung Cheon Lee
    Se Ryeon Lee
    Sook Young Lee
    Jong Yeop Kim
    Journal of Anesthesia, 2016, 30 : 377 - 383
  • [35] Comparison of streamlined liner of the pharynx airway (SLIPA™) and laryngeal mask airway: a systematic review and meta-analysis
    Choi, G. J.
    Kang, H.
    Baek, C. W.
    Jung, Y. H.
    Woo, Y. C.
    Kim, S. H.
    Kim, J. G.
    ANAESTHESIA, 2015, 70 (05) : 613 - 622
  • [36] Use of the i-gel® laryngeal mask for management of a difficult airway
    Emmerich, M.
    Dummler, R.
    ANAESTHESIST, 2008, 57 (08): : 779 - 781
  • [37] The comparison of ProSeal and I-gel laryngeal mask airways in anesthetized adult patients under controlled ventilation
    Ekinci, Osman
    Abitagaoglu, Suheyla
    Turan, Guldem
    Sivrikaya, Zubeyir
    Bosna, Gulsen
    Ozgultekin, Asu
    SAUDI MEDICAL JOURNAL, 2015, 36 (04) : 432 - 436
  • [38] Comparison of the I-gel supraglottic airway as a conduit for tracheal intubation with the intubating laryngeal mask airway
    Xue, F. S.
    Wang, Q.
    Yuan, Y. J.
    Xiong, J.
    Liao, X.
    RESUSCITATION, 2010, 81 (07) : 910 - 911
  • [39] The Safety of the Laryngeal Mask Airway in Adenotonsillectomy: A Systematic Review and Meta-Analysis
    Khoury, Sami
    Zabihi-Pour, Dorsa
    Davidson, Jacob
    Poolacherla, Raju
    Nair, Gopakumar
    Biswas, Abhijit
    You, Peng
    Strychowsky, Julie E.
    JOURNAL OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2024, 53 : 19160216241263851
  • [40] Oesophageal seal of the novel supralaryngeal airway device I-Gel™ in comparison with the laryngeal mask airways Classic™ and ProSeal™ using a cadaver model
    Schmidbauer, W.
    Bercker, S.
    Volk, T.
    Bogusch, G.
    Mager, G.
    Kerner, T.
    BRITISH JOURNAL OF ANAESTHESIA, 2009, 102 (01) : 135 - 139