Design and Validation of Synchronous QCT Calibration Phantom: Practical Methodology

被引:16
|
作者
Malekzadeh, Malakeh [1 ]
Abbasi-Rad, Shahrokh [2 ,3 ]
Shahgholi, Mohamad [4 ]
Naghdi, Parisa [2 ]
Hoseini, Marzieh Sadat [2 ]
Yazdi, Niloofar Ayoobi [5 ]
Shiran, Mohammad Bagher [1 ]
Rad, Hamidreza Saligheh [2 ,3 ]
机构
[1] Iran Univ Med Sci, Sch Med, Med Phys Dept, Tehran, Iran
[2] Univ Tehran Med Sci, Quantitat Med Imaging Syst Grp, Res Ctr Mol & Cellular Imaging, Tehran, Iran
[3] Univ Tehran Med Sci, Med Phys & Biomed Engn Dept, Tehran, Iran
[4] Islamic Azad Univ, Najafabad Branch, Young Researchers & Elite Club, Najafabad, Iran
[5] Univ Tehran Med Sci, Adv Diagnost & Intervent Radiol ADIR Res Ctr, Tehran, Iran
关键词
Quantitative computed tomography; bone mineral density; calibration phantom; ABAQUS software; QUANTITATIVE COMPUTED-TOMOGRAPHY; BONE-MINERAL DENSITY;
D O I
10.1016/j.jmir.2018.10.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: Quantitative computed tomography (QCT) can supplement dual x-ray absorptiometry by enabling geometric and compartmental bone assessments. Whole-body spiral CT scanners are widely available and require a short scanning time of seconds, in contrast to peripheral QCT scanners, which require several minutes of scanning time. This study designed and evaluated the accuracy and precision of a homemade QCT calibration phantom using a whole-body spiral CT scanner. Materials and Methods: The QCT calibration phantom consisted of K2HPO4 solutions as reference. The reference material with various concentrations of 0, 50, 100, 200, 400, 1000, and 1200 mg/cc of K2HPO4 in water were used. For designing the phantom, we used the ABAQUS software. Results: The phantoms were used for performance assessment of QCT method through measurement of accuracy and precision errors, which were generally less than 5.10/0 for different concentrations. The correlation between CT numbers and concentration were close to one (R2 0.99). Discussion: Because whole-body spiral CT scanners allow central bone densitometry, evaluating the accuracy and precision for the easy to use calibration phantom may improve the QCT bone densitometry test. Conclusion: This study provides practical directions for applying a homemade calibration phantom for bone mineral density quantification in QCT technique.
引用
收藏
页码:157 / 162
页数:6
相关论文
共 50 条
  • [41] Design and Validation of an Electric Circuit Phantom for Galvanic Intrabody Communication
    Amparo Callejon, M.
    Reina-Tosina, Javier
    Naranjo, David
    Roa, Laura M.
    XIV MEDITERRANEAN CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING AND COMPUTING 2016, 2016, 57 : 461 - 465
  • [42] EXPERIMENTAL VALIDATION OF ACTIVE FIXTURE DESIGN METHODOLOGY
    Papastathis, Thomas N.
    Bakker, Otto Jan
    Ratchev, Svetan M.
    Popov, Atanas A.
    PROCEEDINGS OF THE ASME 9TH INTERNATIONAL MANUFACTURING SCIENCE AND ENGINEERING CONFERENCE, 2014, VOL 2, 2014,
  • [43] A Remote Methodology for Embedded Systems Design and Validation
    Alessandro Fin
    Franco Fummi
    Design Automation for Embedded Systems, 2003, 8 : 229 - 247
  • [44] Design and Validation Methodology for Biomedical Technology Assessment
    Torres, C. E.
    Rodriguez-Denis, E. B.
    Obando, F. M.
    5TH LATIN AMERICAN CONGRESS ON BIOMEDICAL ENGINEERING (CLAIB 2011): SUSTAINABLE TECHNOLOGIES FOR THE HEALTH OF ALL, PTS 1 AND 2, 2013, 33 (1-2): : 563 - 566
  • [45] A remote methodology for embedded systems design and validation
    Fin, A
    Fummi, F
    DESIGN AUTOMATION FOR EMBEDDED SYSTEMS, 2003, 8 (2-3) : 229 - 247
  • [46] Model validation methodology for design of micro systems
    Anac, Ozan
    Basdogan, Ipek
    PROCEEDINGS OF THE 8TH BIENNIAL CONFERENCE ON ENGINEERING SYSTEMS DESIGN AND ANALYSIS, VOL 2, 2006, : 981 - 987
  • [47] Practical validation of flow meter design environment
    Michalski, Andrzej
    Watral, Zbigniew
    Starzynski, Jacek
    Szmurlo, Robert
    Sienkiewicz, Jan
    PRZEGLAD ELEKTROTECHNICZNY, 2011, 87 (05): : 107 - 110
  • [48] Practical Validation of a Flow Meter Design Environment
    Watral, Zbigniew
    Michalski, Andrzej
    IEEE INSTRUMENTATION & MEASUREMENT MAGAZINE, 2011, 14 (02) : 42 - 47
  • [49] DESIGN AND VALIDATION OF A PRACTICAL INDEX FOR TRAUMA ASSESSMENT
    GUZMAN, N
    PAZ, MX
    PAZ, MI
    MORENO, NR
    NINO, F
    DISASTERS, 1989, 13 (02) : 153 - 164
  • [50] Modelling of thermal hydraulics in a KAROLINA calorimeter for its calibration methodology validation
    Luks, Aleksandra
    Pytel, Krzysztof
    Tarchalski, Mikolaj
    Uzunow, Nikolaj
    Krok, Tomasz
    NUKLEONIKA, 2016, 61 (04) : 453 - 460