Design and Validation of Synchronous QCT Calibration Phantom: Practical Methodology

被引:16
|
作者
Malekzadeh, Malakeh [1 ]
Abbasi-Rad, Shahrokh [2 ,3 ]
Shahgholi, Mohamad [4 ]
Naghdi, Parisa [2 ]
Hoseini, Marzieh Sadat [2 ]
Yazdi, Niloofar Ayoobi [5 ]
Shiran, Mohammad Bagher [1 ]
Rad, Hamidreza Saligheh [2 ,3 ]
机构
[1] Iran Univ Med Sci, Sch Med, Med Phys Dept, Tehran, Iran
[2] Univ Tehran Med Sci, Quantitat Med Imaging Syst Grp, Res Ctr Mol & Cellular Imaging, Tehran, Iran
[3] Univ Tehran Med Sci, Med Phys & Biomed Engn Dept, Tehran, Iran
[4] Islamic Azad Univ, Najafabad Branch, Young Researchers & Elite Club, Najafabad, Iran
[5] Univ Tehran Med Sci, Adv Diagnost & Intervent Radiol ADIR Res Ctr, Tehran, Iran
关键词
Quantitative computed tomography; bone mineral density; calibration phantom; ABAQUS software; QUANTITATIVE COMPUTED-TOMOGRAPHY; BONE-MINERAL DENSITY;
D O I
10.1016/j.jmir.2018.10.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: Quantitative computed tomography (QCT) can supplement dual x-ray absorptiometry by enabling geometric and compartmental bone assessments. Whole-body spiral CT scanners are widely available and require a short scanning time of seconds, in contrast to peripheral QCT scanners, which require several minutes of scanning time. This study designed and evaluated the accuracy and precision of a homemade QCT calibration phantom using a whole-body spiral CT scanner. Materials and Methods: The QCT calibration phantom consisted of K2HPO4 solutions as reference. The reference material with various concentrations of 0, 50, 100, 200, 400, 1000, and 1200 mg/cc of K2HPO4 in water were used. For designing the phantom, we used the ABAQUS software. Results: The phantoms were used for performance assessment of QCT method through measurement of accuracy and precision errors, which were generally less than 5.10/0 for different concentrations. The correlation between CT numbers and concentration were close to one (R2 0.99). Discussion: Because whole-body spiral CT scanners allow central bone densitometry, evaluating the accuracy and precision for the easy to use calibration phantom may improve the QCT bone densitometry test. Conclusion: This study provides practical directions for applying a homemade calibration phantom for bone mineral density quantification in QCT technique.
引用
收藏
页码:157 / 162
页数:6
相关论文
共 50 条
  • [21] Design and fabrication of a multipurpose thyroid phantom for medical dosimetry and calibration
    Naderi, Simin Mehdizadeh
    Sina, Sedigheh
    Karimipoorfard, Mehrnoosh
    Lotfalizadeh, Fatemeh
    Entezarmahdi, Mohammad
    Moradi, Hamed
    Faghihi, Reza
    RADIATION PROTECTION DOSIMETRY, 2016, 168 (04) : 503 - 508
  • [22] Design, Implementation, and Validation of a Pulsatile Heart Phantom Pump
    Tuncay, Volkan
    Zijlstra, Jan
    Oudkerk, Matthijs
    van Ooijen, Peter M. A.
    JOURNAL OF DIGITAL IMAGING, 2020, 33 (05) : 1301 - 1305
  • [23] Design of a fatty plaque phantom for validation of strain imaging
    Boekhoven, R. W.
    Rutten, M. C. M.
    van de Vosse, F. N.
    Lopata, R. G. P.
    2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 2619 - 2622
  • [24] Design, Implementation, and Validation of a Pulsatile Heart Phantom Pump
    Volkan Tuncay
    Jan Zijlstra
    Matthijs Oudkerk
    Peter M. A van Ooijen
    Journal of Digital Imaging, 2020, 33 : 1301 - 1305
  • [25] Synchronous Reluctance Motor: Design, Optimization and Validation
    Tursini, M.
    Villani, M.
    Fabri, G.
    Credo, A.
    Parasiliti, F.
    Abdelli, A.
    2018 INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS, ELECTRICAL DRIVES, AUTOMATION AND MOTION (SPEEDAM), 2018, : 1297 - 1302
  • [26] The Chaboche nonlinear kinematic hardening model: calibration methodology and validation
    Giovanni B. Broggiato
    Francesca Campana
    Luca Cortese
    Meccanica, 2008, 43 : 115 - 124
  • [27] Empirical and Comparative Validation for a Building Energy Model Calibration Methodology
    Gutierrez Gonzalez, Vicente
    Ramos Ruiz, German
    Fernandez Bandera, Carlos
    SENSORS, 2020, 20 (17) : 1 - 29
  • [28] Calibration and Validation Methodology for Simulation Models of Intelligent Work Zones
    Zhao, Li
    Rilett, Laurence R.
    Haque, Mm Shakiul
    TRANSPORTATION RESEARCH RECORD, 2022, 2676 (05) : 500 - 513
  • [29] Methodology for construction, calibration and validation of a national hydrological model for Denmark
    Henriksen, HJ
    Troldborg, L
    Nyegaard, P
    Sonnenborg, TO
    Refsgaard, JC
    Madsen, B
    JOURNAL OF HYDROLOGY, 2003, 280 (1-4) : 52 - 71
  • [30] The Chaboche nonlinear kinematic hardening model: calibration methodology and validation
    Broggiato, Giovanni B.
    Campana, Francesca
    Cortese, Luca
    MECCANICA, 2008, 43 (02) : 115 - 124