Design and Validation of Synchronous QCT Calibration Phantom: Practical Methodology

被引:16
|
作者
Malekzadeh, Malakeh [1 ]
Abbasi-Rad, Shahrokh [2 ,3 ]
Shahgholi, Mohamad [4 ]
Naghdi, Parisa [2 ]
Hoseini, Marzieh Sadat [2 ]
Yazdi, Niloofar Ayoobi [5 ]
Shiran, Mohammad Bagher [1 ]
Rad, Hamidreza Saligheh [2 ,3 ]
机构
[1] Iran Univ Med Sci, Sch Med, Med Phys Dept, Tehran, Iran
[2] Univ Tehran Med Sci, Quantitat Med Imaging Syst Grp, Res Ctr Mol & Cellular Imaging, Tehran, Iran
[3] Univ Tehran Med Sci, Med Phys & Biomed Engn Dept, Tehran, Iran
[4] Islamic Azad Univ, Najafabad Branch, Young Researchers & Elite Club, Najafabad, Iran
[5] Univ Tehran Med Sci, Adv Diagnost & Intervent Radiol ADIR Res Ctr, Tehran, Iran
关键词
Quantitative computed tomography; bone mineral density; calibration phantom; ABAQUS software; QUANTITATIVE COMPUTED-TOMOGRAPHY; BONE-MINERAL DENSITY;
D O I
10.1016/j.jmir.2018.10.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: Quantitative computed tomography (QCT) can supplement dual x-ray absorptiometry by enabling geometric and compartmental bone assessments. Whole-body spiral CT scanners are widely available and require a short scanning time of seconds, in contrast to peripheral QCT scanners, which require several minutes of scanning time. This study designed and evaluated the accuracy and precision of a homemade QCT calibration phantom using a whole-body spiral CT scanner. Materials and Methods: The QCT calibration phantom consisted of K2HPO4 solutions as reference. The reference material with various concentrations of 0, 50, 100, 200, 400, 1000, and 1200 mg/cc of K2HPO4 in water were used. For designing the phantom, we used the ABAQUS software. Results: The phantoms were used for performance assessment of QCT method through measurement of accuracy and precision errors, which were generally less than 5.10/0 for different concentrations. The correlation between CT numbers and concentration were close to one (R2 0.99). Discussion: Because whole-body spiral CT scanners allow central bone densitometry, evaluating the accuracy and precision for the easy to use calibration phantom may improve the QCT bone densitometry test. Conclusion: This study provides practical directions for applying a homemade calibration phantom for bone mineral density quantification in QCT technique.
引用
收藏
页码:157 / 162
页数:6
相关论文
共 50 条
  • [31] Generic Wideband Phantom Design Methodology for Microwave Medical Applications
    Gong, Zheng
    Chen, Yifan
    Lin, Xiaoyou
    Wu, Kunlun
    Cree, Michael J.
    IEEE ANTENNAS AND WIRELESS PROPAGATION LETTERS, 2021, 20 (08): : 1488 - 1492
  • [32] Practical Methodology for the Design of Educational Serious Games
    Silva, Frutuoso G. M.
    INFORMATION, 2020, 11 (01)
  • [33] Practical methodology for distillation design using a miniplant
    Ouni, T
    Lievo, P
    Uusi-Kyyny, P
    Dell'Era, C
    Jakobsson, K
    Pyhälahti, A
    Aittamaa, J
    CHEMICAL ENGINEERING & TECHNOLOGY, 2006, 29 (01) : 104 - 112
  • [34] METHODOLOGY FOR THE CALIBRATION OF PHOTON PERSONAL DOSIMETERS - CALCULATIONS OF PHANTOM BACKSCATTER AND DEPTH DOSE DISTRIBUTIONS
    BARTLETT, DT
    FRANCIS, TM
    DIMBYLOW, PJ
    RADIATION PROTECTION DOSIMETRY, 1989, 27 (04) : 231 - 244
  • [35] A Novel Design of N-Fiducial Phantom for Automatic Ultrasound Calibration
    Chatrasingh, Maria
    Suthakorn, Jackrit
    JOURNAL OF MEDICAL PHYSICS, 2019, 44 (03) : 191 - 200
  • [36] Design and Testing of a Novel Phantom for Camera Calibration of Skin Tones with SGRT
    Bry, V.
    Bice, N.
    Kirby, N.
    Saenz, D.
    Papanikolaou, N.
    Rasmussen, K.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [37] Automatic phantom-less QCT system with high precision of BMD measurement for osteoporosis screening: Technique optimisation and clinical validation
    Liu, Zhuo-Jie
    Zhang, Cheng
    Ma, Chi
    Qi, Huan
    Yang, Ze-Hong
    Wu, Hao-Yu
    Yang, Ke-Di
    Lin, Jun-Yu
    Wong, Tak-Man
    Li, Zhao-Yang
    Li, Chun-Hai
    Ding, Yue
    JOURNAL OF ORTHOPAEDIC TRANSLATION, 2022, 33 : 24 - 30
  • [38] Practical guide to the design, fabrication, and calibration of NIST nanocalorimeters
    Yi F.
    Grapes M.D.
    LaVan D.A.
    Journal of Research of the National Institute of Standards and Technology, 2019, 124
  • [39] Practical guidelines for reliability-based design calibration
    Phoon, KK
    Proceedings of the Twelfth Asian Regional Conference on Soil Mechanics and Geotechnical Engineering, Vol 1 and 2, 2003, : 1349 - 1350
  • [40] Practical Guide to the Design, Fabrication, and Calibration of NIST Nanocalorimeters
    Yi, Feng
    Grapes, Michael D.
    LaVan, David A.
    JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 2019, 124