Design and Validation of Synchronous QCT Calibration Phantom: Practical Methodology

被引:16
|
作者
Malekzadeh, Malakeh [1 ]
Abbasi-Rad, Shahrokh [2 ,3 ]
Shahgholi, Mohamad [4 ]
Naghdi, Parisa [2 ]
Hoseini, Marzieh Sadat [2 ]
Yazdi, Niloofar Ayoobi [5 ]
Shiran, Mohammad Bagher [1 ]
Rad, Hamidreza Saligheh [2 ,3 ]
机构
[1] Iran Univ Med Sci, Sch Med, Med Phys Dept, Tehran, Iran
[2] Univ Tehran Med Sci, Quantitat Med Imaging Syst Grp, Res Ctr Mol & Cellular Imaging, Tehran, Iran
[3] Univ Tehran Med Sci, Med Phys & Biomed Engn Dept, Tehran, Iran
[4] Islamic Azad Univ, Najafabad Branch, Young Researchers & Elite Club, Najafabad, Iran
[5] Univ Tehran Med Sci, Adv Diagnost & Intervent Radiol ADIR Res Ctr, Tehran, Iran
关键词
Quantitative computed tomography; bone mineral density; calibration phantom; ABAQUS software; QUANTITATIVE COMPUTED-TOMOGRAPHY; BONE-MINERAL DENSITY;
D O I
10.1016/j.jmir.2018.10.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: Quantitative computed tomography (QCT) can supplement dual x-ray absorptiometry by enabling geometric and compartmental bone assessments. Whole-body spiral CT scanners are widely available and require a short scanning time of seconds, in contrast to peripheral QCT scanners, which require several minutes of scanning time. This study designed and evaluated the accuracy and precision of a homemade QCT calibration phantom using a whole-body spiral CT scanner. Materials and Methods: The QCT calibration phantom consisted of K2HPO4 solutions as reference. The reference material with various concentrations of 0, 50, 100, 200, 400, 1000, and 1200 mg/cc of K2HPO4 in water were used. For designing the phantom, we used the ABAQUS software. Results: The phantoms were used for performance assessment of QCT method through measurement of accuracy and precision errors, which were generally less than 5.10/0 for different concentrations. The correlation between CT numbers and concentration were close to one (R2 0.99). Discussion: Because whole-body spiral CT scanners allow central bone densitometry, evaluating the accuracy and precision for the easy to use calibration phantom may improve the QCT bone densitometry test. Conclusion: This study provides practical directions for applying a homemade calibration phantom for bone mineral density quantification in QCT technique.
引用
收藏
页码:157 / 162
页数:6
相关论文
共 50 条
  • [1] APPLICATION OF A DIPOTASSIUM PHOSPHATE PHANTOM FOR ASYNCHRONOUS CALIBRATION QCT
    Artyukova, Z.
    Petraikin, A.
    Smorchkova, A.
    Akhmad, E.
    Semenov, D.
    Nisovtsova, L.
    Lobanov, M.
    OSTEOPOROSIS INTERNATIONAL, 2021, 32 (SUPPL 1) : S391 - S391
  • [2] QCT BONE DENSITOMETRY - A NEW METHOD WITHOUT THE USE OF AN EXTERNAL CALIBRATION PHANTOM
    BODEN, SD
    GOODENOUGH, DJ
    STOCKHAM, CD
    ALLMAN, RM
    CALCIFIED TISSUE INTERNATIONAL, 1990, 46 (02) : 137 - 137
  • [3] Validation of calibration methods - A practical approach
    Filipe, E
    ADVANCED MATHEMATICAL & COMPUTATIONAL TOOLS IN METROLOGY VI, 2004, 66 : 285 - 292
  • [4] Opportunistic application of phantom-less calibration methods for fracture risk prediction using QCT/FEA
    Prado, Maria
    Khosla, Sundeep
    Chaput, Christopher
    Giambini, Hugo
    EUROPEAN RADIOLOGY, 2021, 31 (12) : 9428 - 9435
  • [5] Opportunistic application of phantom-less calibration methods for fracture risk prediction using QCT/FEA
    Maria Prado
    Sundeep Khosla
    Christopher Chaput
    Hugo Giambini
    European Radiology, 2021, 31 : 9428 - 9435
  • [6] Design and development of an ultrasound calibration phantom and system
    Cheng, Alexis
    Ackerman, Martin K.
    Chirikjian, Gregory S.
    Boctor, Emad M.
    MEDICAL IMAGING 2014: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2014, 9036
  • [7] Design and validation of a phantom for transcranial ultrasonography
    Denis Leonov
    Maria Kodenko
    Daria Leichenco
    Anastasia Nasibullina
    Nicholas Kulberg
    International Journal of Computer Assisted Radiology and Surgery, 2022, 17 : 1579 - 1588
  • [8] Design and validation of a phantom for transcranial ultrasonography
    Denis, Leonov
    Maria, Kodenko
    Daria, Leichenco
    Anastasia, Nasibullina
    Nicholas, Kulberg
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2022, 17 (09) : 1579 - 1588
  • [9] Methodology for calibration/validation of deterministic models in the catchment
    Arley Toledo-Cubillos, Edwin
    Galvis-Castano, Alberto
    TECNOLOGIA Y CIENCIAS DEL AGUA, 2022, 13 (04) : 127 - 166
  • [10] A calibration methodology of QCT BMD for human vertebral body with registered micro-CT images
    Dall'Ara, E.
    Varga, P.
    Pahr, D.
    Zysset, P.
    MEDICAL PHYSICS, 2011, 38 (05) : 2602 - 2608