Direct enzymatic assay for %HbA1c in human whole blood samples

被引:48
|
作者
Liu, Limin [1 ]
Hood, Stefanie [1 ]
Wang, Yuping [1 ]
Bezverkov, Robert [1 ]
Dou, Chao [1 ]
Datta, Abhijit [1 ]
Yuan, Chong [1 ]
机构
[1] Diazyme Labs, Poway, CA 92064 USA
关键词
HbA1c; glycated hemoglobin; enzymatic HbA1c; human whole blood; diabetes;
D O I
10.1016/j.clinbiochem.2008.01.013
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: Development and validation of a direct enzymatic HbA1c assay that utilizes a single channel on chemistry auto-analyzers without the need to run separate glycated hemoglobin and total hemoglobin assays. Design and methods: An enzyme based single channel assay was developed to measure %HbA1c in human whole blood samples. The performance characteristics of the Diazyme Direct Enzymatic HbA1c Assay were evaluated on the Hitachi 917 auto-analyzer using whole blood samples, appropriate controls and a reference lot of manufactured reagents. Accuracy studies were completed by comparing the Direct Enzymatic Assay to existing HPLC and immunoassay methods. Interference testing was performed to determine the effect of total hemoglobin, glycated serum proteins, chemical substances and hemoglobin variants in patient samples. Results: The Direct Enzymatic HbA1c Assay showed within run precision and total precision results of <= 2% CV for both normal and abnormal level samples. Method comparison studies showed that there was a good correlation between the Direct Enzymatic HbA1c and the HPLC (R-2=0.98) or the immunoassay (R-2=0.97) methods. The assay measured within the range of 4-16% HbA1c and showed excellent performance with variant hemoglobin in samples. Conclusions: Diazyme Direct Enzymatic HbA1c Assay is accurate and precise when compared to currently marketed medical devices. The assay is designed to report %HbA1c values directly without need for a separate measurement of total hemoglobin and is not adversely affected by interferences from common hemoglobin variants in samples. It is a cost effective, user-friendly method and is adaptable to most general chemistry analyzers. (c) 2008 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:576 / 583
页数:8
相关论文
共 50 条
  • [41] Positive bias of the Roche Tina-quant® II HbA1c assay at low HbA1c percentages.
    Nowatzke, WL
    Parvin, CA
    Scott, MG
    Hock, K
    Cole, TG
    CLINICAL CHEMISTRY, 2000, 46 (06) : A33 - A34
  • [42] Assessment of HbA1c in capillary blood compared to venous blood
    Valdivia Pereza, Antonio
    Rico Blazquez, Milagros
    Luis Martin, Francisca
    Mingo Plaza, Dolores
    Lozano Garcia, Isabel
    Pizarro Blanco, Maria
    ATENCION PRIMARIA, 2010, 42 (02): : 126 - 127
  • [43] In the Case of HbA1c Variability, Could Predicted HbA1c Be An Alternative?
    Naser, Abdulrahman
    ENDOCRINOLOGY RESEARCH AND PRACTICE, 2025, 29 (01):
  • [44] HbA1c : EQA in Germany, Belgium and the Netherlands using fresh whole blood samples with target values assigned with the IFCC reference system
    Kaiser, Patricia
    Spannagl, Michael
    van Campenhout, Christel
    Lenga, Yolande
    Siebelder, Carla
    Weykamp, Cas
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2016, 54 (11) : 1769 - 1775
  • [45] A disposable electrochemical sensor designed to estimate glycated hemoglobin (HbA1c) level in whole blood
    Thiruppathi, Murugan
    Lee, Ju-Fang
    Chen, Cheng Che
    Ho, Ja-an Annie
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 329
  • [46] Translating the HbA1c assay into estimated average glucose values
    Jecht, M.
    DIABETOLOGE, 2008, 4 (07): : 561 - 562
  • [47] Evaluation of analytical performance of Sekisui NORUDIA HbA1c assay
    Lee, K.
    Hong, J. W.
    Song, D. Y.
    Kim, S.
    Jun, S.
    Song, S. H.
    Song, J.
    CLINICA CHIMICA ACTA, 2019, 493 : S290 - S290
  • [48] Analytical interference of 33 different hemoglobin variants on HbA1c measurements comparing high-performance liquid chromatography with whole blood enzymatic assay: A multi-center study
    Zechmeister, Bozena
    Erden, Tanja
    Kreutzig, Berit
    Weber, Matthias
    Joly, Philippe
    Erdmann, Juergen
    Brockmann-Ho, Christine
    Fischer, Andreas
    Eidizadeh, Abass
    CLINICA CHIMICA ACTA, 2022, 531 : 145 - 151
  • [49] Comparison of HbA1c measurement in remotely prepared capillary versus standard venous blood samples
    Groenendijk, W.
    Griffin, T.
    Islam, N.
    Blake, L.
    O'Shea, P. M.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2022, 191 (SUPPL 4) : 118 - 119
  • [50] HBA1C AND BLOOD SUGAR LEVELS IN KNOWN DIABETICS
    Odera-Ikamari, E. I.
    Kimengech, K. K.
    Mwangi, D. M.
    Njagi, L. J.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S395 - S395