Direct enzymatic assay for %HbA1c in human whole blood samples

被引:48
|
作者
Liu, Limin [1 ]
Hood, Stefanie [1 ]
Wang, Yuping [1 ]
Bezverkov, Robert [1 ]
Dou, Chao [1 ]
Datta, Abhijit [1 ]
Yuan, Chong [1 ]
机构
[1] Diazyme Labs, Poway, CA 92064 USA
关键词
HbA1c; glycated hemoglobin; enzymatic HbA1c; human whole blood; diabetes;
D O I
10.1016/j.clinbiochem.2008.01.013
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: Development and validation of a direct enzymatic HbA1c assay that utilizes a single channel on chemistry auto-analyzers without the need to run separate glycated hemoglobin and total hemoglobin assays. Design and methods: An enzyme based single channel assay was developed to measure %HbA1c in human whole blood samples. The performance characteristics of the Diazyme Direct Enzymatic HbA1c Assay were evaluated on the Hitachi 917 auto-analyzer using whole blood samples, appropriate controls and a reference lot of manufactured reagents. Accuracy studies were completed by comparing the Direct Enzymatic Assay to existing HPLC and immunoassay methods. Interference testing was performed to determine the effect of total hemoglobin, glycated serum proteins, chemical substances and hemoglobin variants in patient samples. Results: The Direct Enzymatic HbA1c Assay showed within run precision and total precision results of <= 2% CV for both normal and abnormal level samples. Method comparison studies showed that there was a good correlation between the Direct Enzymatic HbA1c and the HPLC (R-2=0.98) or the immunoassay (R-2=0.97) methods. The assay measured within the range of 4-16% HbA1c and showed excellent performance with variant hemoglobin in samples. Conclusions: Diazyme Direct Enzymatic HbA1c Assay is accurate and precise when compared to currently marketed medical devices. The assay is designed to report %HbA1c values directly without need for a separate measurement of total hemoglobin and is not adversely affected by interferences from common hemoglobin variants in samples. It is a cost effective, user-friendly method and is adaptable to most general chemistry analyzers. (c) 2008 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:576 / 583
页数:8
相关论文
共 50 条
  • [31] SCREENING ADOLESCENT BLOOD DONORS FOR HBA1C
    Eason, S.
    Sayers, M. H.
    Goudar, S.
    VOX SANGUINIS, 2013, 105 : 104 - 105
  • [32] Evaluation of the DCA Vantage analyzer for HbA1c assay
    Szymezak, Jean
    Leroy, Nathalie
    Lavalard, Emmanuelle
    Gillery, Philippe
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2008, 46 (08) : 1195 - 1198
  • [33] HbA1c and blood glucose for the diagnosis of diabetes
    Misra, Anoop
    Garg, Satish
    LANCET, 2011, 378 (9786): : 104 - 106
  • [34] Glycated haemoglobin A1c (HbA1c) in the diagnosis of diabetes mellitus: don't forget the performance of the HbA1c assay
    Schindhelm, R. K.
    Lenters-Westra, E.
    Slingerland, R. J.
    DIABETIC MEDICINE, 2010, 27 (10) : 1214 - 1215
  • [35] Personality and HbA1c: Findings from six samples
    Stephan, Yannick
    Sutin, Angelina R.
    Luchetti, Martina
    Canada, Brice
    Terracciano, Antonio
    PSYCHONEUROENDOCRINOLOGY, 2020, 120
  • [36] Evaluation of HbA1c on capillary blood samples with Sebia CAPILLARYS 2 Flex Piercing
    Heylen, O.
    Van Neyghem, S.
    Exterbille, S.
    Wehlou, C.
    Gorus, F.
    Weets, I.
    ACTA CLINICA BELGICA, 2014, 69 : 7 - 8
  • [37] Measurement glycosylated hba1c in dried blood samples of diabetic patients by paper filter
    Tabatabaei-Malazy, O.
    Delavari, A.
    Heshmat, R.
    Vosoogh, A.
    Omidfar, K.
    Larijani, B.
    DIABETES OBESITY & METABOLISM, 2010, 12 : 74 - 74
  • [38] STABILITY OF MAILED AND COURIERED CAPILLARY HBA1C SAMPLES
    VOSS, EM
    CEMBROWSKI, GS
    HAIG, B
    SPENCER, ML
    DIABETES CARE, 1993, 16 (04) : 665 - 666
  • [39] Heterozygous hemoglobin Hamadan affects HbA1C assay
    Gunton, JE
    McElduff, A
    DIABETES CARE, 1999, 22 (01) : 177 - 177
  • [40] Whole blood HbA1c assay with automated sample pretreatment on Beckman Coulter's SYNCHRON LX®20 clinical systems
    Mu, X
    Le, H
    Cheung, M
    Santo, N
    Higgins, T
    Peters, C
    Roper, L
    CLINICAL CHEMISTRY, 2005, 51 : A111 - A111