Direct enzymatic assay for %HbA1c in human whole blood samples

被引:48
|
作者
Liu, Limin [1 ]
Hood, Stefanie [1 ]
Wang, Yuping [1 ]
Bezverkov, Robert [1 ]
Dou, Chao [1 ]
Datta, Abhijit [1 ]
Yuan, Chong [1 ]
机构
[1] Diazyme Labs, Poway, CA 92064 USA
关键词
HbA1c; glycated hemoglobin; enzymatic HbA1c; human whole blood; diabetes;
D O I
10.1016/j.clinbiochem.2008.01.013
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: Development and validation of a direct enzymatic HbA1c assay that utilizes a single channel on chemistry auto-analyzers without the need to run separate glycated hemoglobin and total hemoglobin assays. Design and methods: An enzyme based single channel assay was developed to measure %HbA1c in human whole blood samples. The performance characteristics of the Diazyme Direct Enzymatic HbA1c Assay were evaluated on the Hitachi 917 auto-analyzer using whole blood samples, appropriate controls and a reference lot of manufactured reagents. Accuracy studies were completed by comparing the Direct Enzymatic Assay to existing HPLC and immunoassay methods. Interference testing was performed to determine the effect of total hemoglobin, glycated serum proteins, chemical substances and hemoglobin variants in patient samples. Results: The Direct Enzymatic HbA1c Assay showed within run precision and total precision results of <= 2% CV for both normal and abnormal level samples. Method comparison studies showed that there was a good correlation between the Direct Enzymatic HbA1c and the HPLC (R-2=0.98) or the immunoassay (R-2=0.97) methods. The assay measured within the range of 4-16% HbA1c and showed excellent performance with variant hemoglobin in samples. Conclusions: Diazyme Direct Enzymatic HbA1c Assay is accurate and precise when compared to currently marketed medical devices. The assay is designed to report %HbA1c values directly without need for a separate measurement of total hemoglobin and is not adversely affected by interferences from common hemoglobin variants in samples. It is a cost effective, user-friendly method and is adaptable to most general chemistry analyzers. (c) 2008 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:576 / 583
页数:8
相关论文
共 50 条
  • [21] HbA1c method evaluation for postmortem samples
    Terhi Keltanen
    Antti Sajantila
    Tiina Valonen
    Teija Partanen
    Katarina Lindroos
    Forensic Science, Medicine, and Pathology, 2015, 11 : 35 - 39
  • [22] Dried blood spots and HbA1c
    Holt, R. I. G.
    DIABETIC MEDICINE, 2020, 37 (09) : 1417 - 1417
  • [23] A glycosylated hemoglobin (HbA1c) biosensing in human whole blood based on the boronate-diol interaction
    Yoon, Ho Won
    Yoon, Hyun C.
    JOURNAL OF BIOSCIENCE AND BIOENGINEERING, 2009, 108 : S156 - S156
  • [24] Sample transport and/or storage can cause falsely low HbA1c levels in blood cells measured by enzymatic assay
    Koga, Masafumi
    Okumiya, Toshika
    Ishibashi, Midori
    DIABETOLOGY INTERNATIONAL, 2020, 11 (02) : 155 - 157
  • [25] Evaluation of the COBAS Integra*HbA1c test from whole blood.
    Peeters, JABM
    Albers, ABM
    Wanger, M
    van Pelt, J
    CLINICAL CHEMISTRY, 1999, 45 (06) : A132 - A132
  • [26] Underfilled blood tube containing EDTA: Is it an inappropriate sample for HbA1c assay?
    Guven, Berrak
    Benice, Ismail
    Can, Murat
    BIOCHEMIA MEDICA, 2023, 33 (01) : 87 - 90
  • [27] Development of aptamer based colorimetric assay for whole blood glycated hemoglobin (HbA1c) estimation using gold nanoparticles
    Devi R.
    Chauhan A.
    Yadav S.
    Kumar P.
    Pundir C.S.
    Biosensors and Bioelectronics: X, 2023, 13
  • [28] Atellica® DCA analyzer HbA1c assay demonstrates good precision across various HbA1c levels
    Yost, C.
    Tsai, C.
    Porod, H.
    Kauffmann, A.
    Boone, J.
    Ellis, N.
    Stradinger, J.
    CLINICA CHIMICA ACTA, 2024, 558
  • [29] Rapid determination of glycosylated human hemoglobin (HbA1c) concentration in whole blood by ambient liquid mass spectrometry
    Yuan, C. -H.
    Hung, W. -C.
    Chang, H. -C.
    Lin, H. -Y.
    Liu, J. -J.
    Shiea, J.
    MOLECULAR & CELLULAR PROTEOMICS, 2006, 5 (10) : S352 - S352
  • [30] Approved IFCC reference method for the measurement of HbA1c in human blood
    Jeppsson, JO
    Kobold, U
    Barr, J
    Finke, A
    Hoelzel, W
    Hoshino, T
    Miedema, K
    Mosca, A
    Mauri, P
    Paroni, R
    Thienpont, L
    Umemoto, M
    Weykamp, C
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2002, 40 (01) : 78 - 89