Relationship of SITA and full-threshold standard perimetry to frequency-doubling technology perimetry in glaucoma

被引:13
|
作者
Boden, C
Pascual, J
Medeiros, FA
Aihara, M
Weinreb, RN
Sample, PA
机构
[1] Univ Calif San Diego, Dept Ophthalmol, Hamilton Glaucoma Ctr, La Jolla, CA 92093 USA
[2] Univ Calif San Diego, Visual Funct Lab, La Jolla, CA 92093 USA
[3] Univ Tokyo, Dept Ophthalmol, Tokyo 113, Japan
关键词
D O I
10.1167/iovs.04-1108
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To compare full-threshold (FT) and SITA algorithms for standard automated perimetry (SAP) with frequency-doubling technology perimetry (FDT) in glaucoma, to help clinicians to relate results in patients who have had two or more of these tests during follow-up. METHODS. This study was a retrospective analysis of data from a longitudinal prospective study at the University of California, San Diego. One hundred four eyes of 104 patients with glaucomatous optic neuropathy detected by optic disc stereophotographs were included. All patients had standard perimetry (SITA and FT) and FDT within 3 months of each other. Global indices, abnormality and severity using two threshold algorithms of standard perimetry were compared with FDT. RESULTS. More eyes had normal visual fields by SAP-FT (57 eyes) than by either SAP-SITA (42 eyes) or FDT (45 eyes), although SAP-FT agreed more closely with FDT (kappa = 0.54 +/- 0.08) on the presence of a visual field defect than did SAP-SITA (kappa = 0.34 +/- 0.08). Correlations of FDT to standard perimetry global indices were similar regardless of the threshold strategy used for standard perimetry, yielding r(2) = 0.38-0.57 for SAP-FT with FDT, 0.36-0.54 for SAP-SITA with FDT. CONCLUSIONS. Despite many similarities of SAP-SITA and SAP-FT, switching the standard of comparison from SAP-FT to SAP-SITA changes the relationship to FDT with regard to visual field abnormality, but not correlations of global indices. FDT detected abnormal fields in more eyes than SAP-FT. SAP-FT tended to detect a subset of eyes found abnormal by FDT. Visual field defects may be detected more often by FDT and SAP-SITA in eyes with early visual field loss, but these two tests may not agree on which eyes show field loss in patients who undergo both tests at follow-up.
引用
收藏
页码:2433 / 2439
页数:7
相关论文
共 50 条
  • [1] Comparison between frequency-doubling technology perimetry and standard automated perimetry in early glaucoma
    Seong Ah Kim
    Chan Kee Park
    Hae-Young Lopilly Park
    Scientific Reports, 12
  • [2] Comparison between frequency-doubling technology perimetry and standard automated perimetry in early glaucoma
    Kim, Seong Ah
    Park, Chan Kee
    Park, Hae-Young Lopilly
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [3] Standard automated perimetry sita and full-threshold strategies compared to SWAP and FDT in glaucoma
    Boden, C
    Sample, PA
    Weinreb, RN
    PERIMETRY UPDATE 2002/2003, 2004, : 149 - 150
  • [4] Frequency-doubling perimetry: Comparison with standard automated perimetry to detect glaucoma
    Leeprechanon, Narakorn
    Giangiacomo, Annette
    Fontana, Hector
    Hoffman, Douglas
    Caprioli, Joseph
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (02) : 263 - 271
  • [5] Threshold and variability properties of matrix frequency-doubling technology and standard automated perimetry in glaucoma
    Artes, PH
    Hutchison, DM
    Nicolela, MT
    LeBlanc, RP
    Chauhan, BC
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (07) : 2451 - 2457
  • [6] Comparison of Frequency Doubling Technology Full-Threshold and Swedish interactive technology algorithm Standard perimetry in children
    Moya, FJ
    Moya, AZ
    Stinnett, S
    Freedman, SF
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U513 - U513
  • [7] Variability components of standard automated perimetry and frequency-doubling technology perimetry
    Spry, PGD
    Johnson, CA
    McKendrick, AM
    Turpin, A
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (06) : 1404 - 1410
  • [8] Sensitivity and specificity of frequency-doubling technology, tendency-oriented perimetry, SITA Standard and SITA Fast perimetry in perimetrically inexperienced individuals
    de Tarso Ponte Pierre-Filho, Paulo
    Schimiti, Rui Barroso
    Cabral de Vasconcellos, Jose Paulo
    Costa, Vital Paulino
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 2006, 84 (03): : 345 - 350
  • [9] Comparison of Standard Automated Perimetry, Frequency-Doubling Technology Perimetry, and Short-Wavelength Automated Perimetry for Detection of Glaucoma
    Liu, Shu
    Lam, Shi
    Weinreb, Robert N.
    Ye, Cong
    Cheung, Carol Y.
    Lai, Gilda
    Lam, Dennis Shun-Chiu
    Leung, Christopher Kai-Shun
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (10) : 7325 - 7331
  • [10] Short-wavelength automated perimetry and frequency-doubling technology perimetry in glaucoma
    Fogagnolo, Paolo
    Rossetti, Luca
    Ranno, Stefano
    Ferreras, Antonio
    Orzalesi, Nicola