Amperometric L-lactate biosensor based on screen-printed carbon electrode containing cobalt phthalocyanine, coated with lactate oxidase-mesoporous silica conjugate layer

被引:54
|
作者
Shimomura, Takeshi [1 ]
Sumiya, Touru [1 ]
Ono, Masatoshi [1 ]
Ito, Tetsuji [2 ]
Hanaoka, Taka-aki [2 ]
机构
[1] Funai Elect Adv Appl Technol Res Inst Inc FEAT, Tsukuba, Ibaraki 3050047, Japan
[2] Natl Inst Adv Ind Sci & Technol, Miyagino Ku, Sendai, Miyagi 9838551, Japan
基金
日本科学技术振兴机构;
关键词
Screen-printed carbon electrode; Cobalt phthalocyanine; Lactate oxidase; Mesoporous silica; Nafion; Sampling unit; GLUCOSE BIOSENSOR; ENZYME ELECTRODES; HYDROGEN-PEROXIDE; IMMOBILIZATION; DESIGN; MATRIX; SENSORS; STABILIZATION; BIOCOMPOSITE; SYSTEM;
D O I
10.1016/j.aca.2011.11.053
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel amperometric biosensor for the measurement of L-lactate has been developed. The device comprises a screen-printed carbon electrode containing cobalt phthalocyanine (CoPC-SPCE), coated with lactate oxidase CLOD) that is immobilized in mesoporous silica (FSM8.0) using a polymer matrix of denatured polyvinyl alcohol; a Nafion layer on the electrode surface acts as a barrier to interferents. The sampling unit attached to the SPCE requires only a small sample volume of 100 mu L for each measurement. The measurement of I.-lactate is based on the signal produced by hydrogen peroxide, the product of the enzymatic reaction. The behavior of the biosensor, LOD-FSM8.0/Naf/CoPC-SPCE, was examined in terms of pH, applied potential, sensitivity and operational range, selectivity, and storage stability. The sensor showed an optimum response at a pH of 7.4 and an applied potential of +450 mV. The determination range and the response time for L-lactate were 18.3 mu M to 1.5 mM and approximately 90 s, respectively. In addition, the sensor exhibited high selectivity for I.-lactate and was quite stable in storage, showing no noticeable change in its initial response after being stored for over 9 months. These results indicate that our method provides a simple, cost-effective, high-performance biosensor for L-lactate. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:114 / 120
页数:7
相关论文
共 50 条
  • [41] Amperometric determination of L-lactate based on entrapment of lactate oxidase on a transducer surface with a semi-permeable membrane using a SIRE technology based biosensor. Application: Tomato paste and baby food
    Kriz, K
    Kraft, L
    Krook, M
    Kriz, D
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2002, 50 (12) : 3419 - 3424
  • [42] Glucose biosensor based on screen-printed electrode modified with silicone sol–gel conducting matrix containing carbon nanotubes
    O. A. Kamanina
    S. S. Kamanin
    A. S. Kharkova
    V. A. Arlyapov
    3 Biotech, 2019, 9
  • [43] Glucose biosensor based on screen-printed electrode modified with silicone sol-gel conducting matrix containing carbon nanotubes
    Kamanina, O. A.
    Kamanin, S. S.
    Kharkova, A. S.
    Arlyapov, V. A.
    3 BIOTECH, 2019, 9 (07)
  • [44] Biosensor Based on Screen-Printed Electrode and Glucose-Oxidase Modified with the Addition of Single-Walled Carbon Nanotubes and Thermoexpanded Graphite
    Arlyapov V.A.
    Kamanin S.S.
    Kamanina O.A.
    Reshetilov A.N.
    Nanotechnologies in Russia, 2017, 12 (11-12): : 658 - 666
  • [45] Voltammetric DNA Biosensor based on Gold Nanoparticles-Coated Carbon Screen-Printed Electrode for Genetically Modified Organism (GMO) Detection
    Khairani, Nahdya
    Lau, Han Yih
    Ishak, Zamri
    Heng, Lee Yook
    Tanjabatan, Ling Ling
    SAINS MALAYSIANA, 2022, 51 (10): : 3285 - 3294
  • [46] NADH amperometric sensor based on poly(3-methylthiophene)-coated cylindrical carbon fiber microelectrodes: application to the enzymatic determination of L-lactate
    Jaraba, P
    Agui, L
    Yanez-Sedeno, P
    Pingarron, JM
    ELECTROCHIMICA ACTA, 1998, 43 (23) : 3555 - 3565
  • [47] Amperometric detection of uric acid and hypoxanthine with Xanthine oxidase immobilized and carbon based screen-printed electrode. Application for fish freshness determination
    Carsol, MA
    Volpe, G
    Mascini, M
    TALANTA, 1997, 44 (11) : 2151 - 2159
  • [48] Amperometric, screen-printed, glucose biosensor for analysis of human plasma samples using a biocomposite water-based carbon ink incorporating glucose oxidase
    Crouch, E
    Cowell, DC
    Hoskins, S
    Pittson, RW
    Hart, JP
    ANALYTICAL BIOCHEMISTRY, 2005, 347 (01) : 17 - 23
  • [49] Development of a Disposable, Amperometric Glycerol Biosensor Based on a Screen-Printed Carbon Electrode, Modified with the Electrocatalyst Meldolas Blue, Coated with Glycerol Dehydrogenase and NAD+: Application to the Analysis of Wine Quality
    Ekonomou, Sotirios I.
    Crew, Adrian
    Doran, Olena
    Hart, John P.
    APPLIED SCIENCES-BASEL, 2024, 14 (14):
  • [50] DEVELOPMENT OF AMPEROMETRIC SENSORS FOR URIC-ACID BASED ON CHEMICALLY-MODIFIED GRAPHITE-EPOXY RESIN AND SCREEN-PRINTED ELECTRODES CONTAINING COBALT PHTHALOCYANINE
    GILMARTIN, MAT
    HART, JP
    BIRCH, BJ
    ANALYST, 1994, 119 (02) : 243 - 252