Amperometric L-lactate biosensor based on screen-printed carbon electrode containing cobalt phthalocyanine, coated with lactate oxidase-mesoporous silica conjugate layer

被引:54
|
作者
Shimomura, Takeshi [1 ]
Sumiya, Touru [1 ]
Ono, Masatoshi [1 ]
Ito, Tetsuji [2 ]
Hanaoka, Taka-aki [2 ]
机构
[1] Funai Elect Adv Appl Technol Res Inst Inc FEAT, Tsukuba, Ibaraki 3050047, Japan
[2] Natl Inst Adv Ind Sci & Technol, Miyagino Ku, Sendai, Miyagi 9838551, Japan
基金
日本科学技术振兴机构;
关键词
Screen-printed carbon electrode; Cobalt phthalocyanine; Lactate oxidase; Mesoporous silica; Nafion; Sampling unit; GLUCOSE BIOSENSOR; ENZYME ELECTRODES; HYDROGEN-PEROXIDE; IMMOBILIZATION; DESIGN; MATRIX; SENSORS; STABILIZATION; BIOCOMPOSITE; SYSTEM;
D O I
10.1016/j.aca.2011.11.053
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel amperometric biosensor for the measurement of L-lactate has been developed. The device comprises a screen-printed carbon electrode containing cobalt phthalocyanine (CoPC-SPCE), coated with lactate oxidase CLOD) that is immobilized in mesoporous silica (FSM8.0) using a polymer matrix of denatured polyvinyl alcohol; a Nafion layer on the electrode surface acts as a barrier to interferents. The sampling unit attached to the SPCE requires only a small sample volume of 100 mu L for each measurement. The measurement of I.-lactate is based on the signal produced by hydrogen peroxide, the product of the enzymatic reaction. The behavior of the biosensor, LOD-FSM8.0/Naf/CoPC-SPCE, was examined in terms of pH, applied potential, sensitivity and operational range, selectivity, and storage stability. The sensor showed an optimum response at a pH of 7.4 and an applied potential of +450 mV. The determination range and the response time for L-lactate were 18.3 mu M to 1.5 mM and approximately 90 s, respectively. In addition, the sensor exhibited high selectivity for I.-lactate and was quite stable in storage, showing no noticeable change in its initial response after being stored for over 9 months. These results indicate that our method provides a simple, cost-effective, high-performance biosensor for L-lactate. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:114 / 120
页数:7
相关论文
共 50 条
  • [11] Dataset on fabrication of an improved L-lactate biosensor based on lactate oxidase/cMWCNT/CuNPs/PANI modified PG electrode
    Dagar, Kusum
    Pundir, C. S.
    DATA IN BRIEF, 2018, 17 : 1163 - 1167
  • [12] Dual Biosensor for Simultaneous Monitoring of Lactate and Glucose Based on Thin-layer Flow Cell Screen-printed Electrode
    Kanso, Hussein
    Gonzalez Garcia, Maria Begona
    Ma, Su
    Ludwig, Roland
    Fanjul Bolado, Pablo
    Hernandez Santos, David
    ELECTROANALYSIS, 2017, 29 (01) : 87 - 92
  • [13] AMPEROMETRIC L-LACTATE-SENSING ELECTRODE BASED ON A POLYION COMPLEX LAYER CONTAINING LACTATE OXIDASE - APPLICATION TO SERUM AND MILK SAMPLES
    MIZUTANI, F
    YABUKI, S
    HIRATA, Y
    ANALYTICA CHIMICA ACTA, 1995, 314 (03) : 233 - 239
  • [14] An improved amperometric L-lactate biosensor based on covalent immobilization of microbial lactate oxidase onto carboxylated multiwalled carbon nanotubes/copper nanoparticles/polyaniline modified pencil graphite electrode
    Dagar, Kusum
    Pundir, C. S.
    ENZYME AND MICROBIAL TECHNOLOGY, 2017, 96 : 177 - 186
  • [15] A microband lactate biosensor fabricated using a water-based screen-printed carbon ink
    Rawson, F. J.
    Purcell, W. M.
    Xu, J.
    Pemberton, R. M.
    Fielden, P. R.
    Biddle, N.
    Hart, J. P.
    TALANTA, 2009, 77 (03) : 1149 - 1154
  • [16] Amperometric L-lactate biosensors: 1. Lactic acid sensing electrode containing lactate oxidase in a composite poly-L-lysine matrix
    Iwuoha, EI
    Rock, A
    Smyth, MR
    ELECTROANALYSIS, 1999, 11 (05) : 367 - 373
  • [17] Amperometric Biosensor Based on Diamine Oxidase/Platinum Nanoparticles/Graphene/Chitosan Modified Screen-Printed Carbon Electrode for Histamine Detection
    Apetrei, Irina Mirela
    Apetrei, Constantin
    SENSORS, 2016, 16 (04):
  • [18] High-performance amperometric biosensor for flow injection analysis consisting of a replaceable lactate oxidase-based mini-reactor and a silver amalgam screen-printed electrode
    Tvorynska, Sofiia
    Barek, Jiri
    Josypcuk, Bohdan
    ELECTROCHIMICA ACTA, 2023, 445
  • [19] Continuous sweat lactate monitoring system with integrated screen-printed Mgo-templated carbon-lactate oxidase biosensor and microfluidic sweat collector
    Shitanda, Isao
    Mitsumoto, Masaya
    Loew, Noya
    Yoshihara, Yuko
    Watanabe, Hikari
    Mikawa, Tsutomu
    Tsujimura, Seiya
    Itagaki, Masayuki
    Motosuke, Masahiro
    ELECTROCHIMICA ACTA, 2021, 368 (368)
  • [20] A REAGENTLESS, DISPOSABLE BIOSENSOR FOR LACTIC-ACID BASED ON A SCREEN-PRINTED CARBON ELECTRODE CONTAINING MELDOLAS-BLUE AND COATED WITH LACTATE DEHYDROGENASE, NAD+ AND CELLULOSE-ACETATE
    SPRULES, SD
    HART, JP
    WRING, SA
    PITTSON, R
    ANALYTICA CHIMICA ACTA, 1995, 304 (01) : 17 - 24