Estimation of radiation dose and establishment of local diagnostic reference levels for computed tomography of head in pediatric population

被引:0
|
作者
Priyanka [1 ]
Kadavigere, Rajagopal [2 ]
Sukumar, Suresh [1 ]
机构
[1] Manipal Acad Higher Educ, Manipal Coll Hlth Profess, Dept Med Imaging Technol, Manipal, Karnataka, India
[2] Manipal Acad Higher Educ, Kasturba Med Coll, Dept Radio Diag & Imaging, Manipal 576104, Karnataka, India
关键词
Diagnostic reference levels; pediatric computed tomography; volumetric computed tomography dose index; dose length product; effective dose estimation; CT SCANS; RISK; CANCER; EXPOSURE; ADULT;
D O I
10.3233/XST-221172
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
BACKGROUND: Pediatric population is more sensitive to the effects of radiation than adults. Establishing diagnostic reference level (DRL) is an efficient dose optimization technique implemented by many countries for reducing radiation dose during Computed Tomography (CT) examinations. OBJECTIVES: To estimate radiation dose and establish a new local diagnostic reference level for CT head examination in the pediatric population. MATERIALS AND METHODS: We prospectively recruited 143 pediatric patients referred for CT head examination with age ranging from 0-5 years old. All patients had undergone CT head examination using the standard pediatric head protocol. Volumetric CT dose index (CTDIvol) and dose length product (DLP) were recorded. The effective dose was first calculated. Then, 75th percentile of dose indices was calculated to establish DRLs. RESULTS: DRLs in terms of CTDIvol and DLP are 23.84 mGy, 555.99 mGy.cm for patients <1 years old and 28.65 mGy, 794.99 mGy.cm for patients from 1-5 years old, respectively. Mean effective doses for <1 years old patients and 1-5 years old patients are 2.91 mSv and 2.78 mSv respectively. CONCLUSION: The study concludes that DRL in terms of CTDIvol is lower but DRL in terms of DLP and the effective dose is higher compared to a few other studies which necessitate the need for dose optimization.
引用
收藏
页码:983 / 991
页数:9
相关论文
共 50 条
  • [31] Local Diagnostic Reference Levels and Size-Specific Patient Dose in Computed Tomography at a Greek Hospital
    Stasinou, D.
    Zoiopoulou, V.
    Antonakos, J.
    Argentos, S.
    Efstathopoulos, E.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [32] Establishment of diagnostic reference level for computed tomography of head pediatrics in Morocco: A pilot study
    Semghouli, Slimane
    Aabid, Mohammed
    Amaoui, Bouchra
    Choukri, Abdelmajid
    El Kharras, Abdennasser
    MATERIALS TODAY-PROCEEDINGS, 2022, 52 : 85 - 88
  • [33] Radiation Dose Estimation From Pediatric Cone Beam Computed Tomography
    Kim, S.
    Yoshizumi, T.
    Toncheva, G.
    Yin, F.
    Frush, D.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [34] DIAGNOSTIC REFERENCE LEVELS FOR PAEDIATRIC HEAD COMPUTED TOMOGRAPHY IN MOROCCO: A NATIONWIDE SURVEY
    Benmessaoud, M.
    Dadouch, A.
    Talbi, M.
    Tahiri, M.
    El-ouardi, Y.
    RADIATION PROTECTION DOSIMETRY, 2020, 191 (04) : 400 - 408
  • [35] Establishment of dose reference levels (DRLs) for CT of the head and neck in radiation therapy
    Clerkin, C.
    Brennan, S.
    Mullaney, L.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S985 - S985
  • [36] Establishment of national diagnostic reference levels for radiotherapy computed tomography simulation procedures in Slovenia
    Zalokar, Nika
    Marcius, Valerija Zager
    Mekis, Nejc
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 127
  • [37] Survey of computed tomography doses and establishment of national diagnostic reference levels in the Republic of Belarus
    Kharuzhyk, S. A.
    Matskevich, S. A.
    Filjustin, A. E.
    Bogushevich, E. V.
    Ugolkova, S. A.
    RADIATION PROTECTION DOSIMETRY, 2010, 139 (1-3) : 367 - 370
  • [38] Establishment of national diagnostic reference levels in dental cone beam computed tomography in Switzerland
    Deleu, Marine
    Dagassan, Dorothea
    Berg, Isabelle
    Bize, Julie
    Dula, Karl
    Lenoir, Vincent
    Ott, Barbara
    Ott, Julien G.
    Verdun, Francis R.
    Weber, Robert
    Ziglinas, Panagiotis
    Zingariello, Cesare
    Merce, Marta Sans
    DENTOMAXILLOFACIAL RADIOLOGY, 2020, 49 (06)
  • [40] Towards establishment of the national reference dose levels from computed tomography examinations in Tanzania
    Ngaile, JE
    Msaki, P
    Kazema, R
    JOURNAL OF RADIOLOGICAL PROTECTION, 2006, 26 (02) : 213 - 225