Establishment of national diagnostic reference levels in dental cone beam computed tomography in Switzerland

被引:14
|
作者
Deleu, Marine [1 ,2 ]
Dagassan, Dorothea [3 ]
Berg, Isabelle [4 ]
Bize, Julie [1 ]
Dula, Karl [5 ]
Lenoir, Vincent [2 ]
Ott, Barbara [6 ]
Ott, Julien G. [7 ]
Verdun, Francis R. [1 ]
Weber, Robert [8 ]
Ziglinas, Panagiotis [9 ]
Zingariello, Cesare [2 ]
Merce, Marta Sans [2 ]
机构
[1] Lausanne Univ Hosp, Inst Radiat Phys, Lausanne, Switzerland
[2] Univ Hosp Geneva, Dept Radiol, Geneva, Switzerland
[3] Univ Basel, Univ Ctr Dent Med Basel, Ctr Dent Imaging, Basel, Switzerland
[4] Univ Hosp Basel, Basel, Switzerland
[5] Univ Bern, Bern, Switzerland
[6] Fed Off Publ Hlth, Radiat Protect Div, Bern, Switzerland
[7] HNO Zentrum, Bern, Switzerland
[8] Inselspital Bern, Div Med Radiat Phys, Bern, Switzerland
[9] Praxisklinik, Basel, Switzerland
关键词
Diagnostic reference level; Cone beam computed tomography; Dental Radiography; Dose area product; Clinical DRL; DENTISTRY; CT;
D O I
10.1259/dmfr.20190468
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of this study was to establish diagnostic reference levels (DRLs) in the field of dental maxillofacial and ear-nose-throat (ENT) practices using cone beam CT (CBCT) in Switzerland. Methods: A questionnaire was sent to owners of CBCTs in Switzerland; to a total of 612 institutions. The answers were analyzed for each indication, provided that enough data were available. The DRLs were defined as the 75th percentile of air kerma product distribution (P-KA). Results: 227 answers were collected (38% of all centers). Third quartile of P-KA, values were obtained for five dental indications: 662 mGy cm(2) for wisdom tooth, 683 mGy cm(2) for single tooth implant treatment, 542 mGy cm(2) for tooth position anomalies, 569 mGy cm(2) for pathological dentoalveolar modifications, and 639 mGy cm(2) for endodontics. The standard field of view (FOV) size of 5 cm in diameter x 5 cm in height was proposed. Conclusions: Large ranges of FOV and P were found for a given indication, demonstrating the importance of establishing DRLs as well as FOV recommendations in view of optimizing the present practice. For now, only DRLs for dental and maxillofacial could be defined; because of a lack of ENT data, no DRL values for ENT practices could be derived from this survey.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Establishment of Diagnostic Reference Levels in Cone Beam Computed Tomography Scans in the United Arab Emirates
    Abuzaid, Mohamed M.
    Elshami, Wiam
    Jayachandran, Deepa
    Korappil, Noushad
    Tekin, Huseyin O.
    TOMOGRAPHY, 2022, 8 (06) : 2939 - 2945
  • [2] A European perspective on dental cone beam computed tomography systems with a focus on optimisation utilising diagnostic reference levels
    Siiskonen, Teemu
    Gallagher, Aoife
    Ciraj Bjelac, Olivera
    Novak, Leos
    Sans Merce, Marta
    Farah, Jad
    Dabin, Jeremie
    Malchair, Francoise
    Knezevic, Zeljka
    Kortesniemi, Mika
    JOURNAL OF RADIOLOGICAL PROTECTION, 2021, 41 (02) : 442 - 451
  • [3] Establishment of national diagnostic reference levels as guidelines for computed tomography radiation in Jordan
    Al Ewaidat, Haytham
    Balawi, Sara
    Bataineh, Ziad
    Al-Dwairi, Ahmed
    Al-Khalily, Majd
    Azez, Khalaf Abdel
    Almakhadmeh, Ali
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2023, 33 (04) : 1223 - 1234
  • [4] Establishment of diagnostic reference levels in cardiac computed tomography
    Rawashdeh, Mohammad
    Saade, Charbel
    Zaitoun, Maha
    Abdelrahman, Mostafa
    Brennan, Patrick
    Alewaidat, Haytham
    McEntee, Mark F.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (10): : 181 - 186
  • [5] The establishment of computed tomography diagnostic reference levels in Portugal
    Santos, Joana
    Foley, Shane
    Paulo, Graciano
    McEntee, Mark F.
    Rainford, Louise
    RADIATION PROTECTION DOSIMETRY, 2014, 158 (03) : 307 - 317
  • [6] Establishment of national diagnostic reference levels for radiotherapy computed tomography simulation procedures in Slovenia
    Zalokar, Nika
    Marcius, Valerija Zager
    Mekis, Nejc
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 127
  • [7] Survey of computed tomography doses and establishment of national diagnostic reference levels in the Republic of Belarus
    Kharuzhyk, S. A.
    Matskevich, S. A.
    Filjustin, A. E.
    Bogushevich, E. V.
    Ugolkova, S. A.
    RADIATION PROTECTION DOSIMETRY, 2010, 139 (1-3) : 367 - 370
  • [8] A Contribution to the Establishment of Diagnostic Reference Levels in Computed Tomography in Brazil
    Narciso, L. D. L.
    Lima, N. W.
    Dartora, C. M.
    Marques da Silva, A. M.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 737 - 740
  • [9] Establishment of national diagnostic dose reference levels (DRLs) for routine computed tomography examinations in Jordan
    Radaideh, Khaldoon
    Al-Radaideh, Ali
    Ramli, Ramzun Maizan
    Saleh, Abdallah
    Alshayeb, Rasha
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2023, 29 (01): : 26 - 34
  • [10] Canadian Computed Tomography Survey: National Diagnostic Reference Levels
    Wardlaw, Graeme M.
    Martel, Narine
    MEDICAL PHYSICS, 2016, 43 (08) : 4932 - 4933