Establishment of national diagnostic reference levels in dental cone beam computed tomography in Switzerland

被引:14
|
作者
Deleu, Marine [1 ,2 ]
Dagassan, Dorothea [3 ]
Berg, Isabelle [4 ]
Bize, Julie [1 ]
Dula, Karl [5 ]
Lenoir, Vincent [2 ]
Ott, Barbara [6 ]
Ott, Julien G. [7 ]
Verdun, Francis R. [1 ]
Weber, Robert [8 ]
Ziglinas, Panagiotis [9 ]
Zingariello, Cesare [2 ]
Merce, Marta Sans [2 ]
机构
[1] Lausanne Univ Hosp, Inst Radiat Phys, Lausanne, Switzerland
[2] Univ Hosp Geneva, Dept Radiol, Geneva, Switzerland
[3] Univ Basel, Univ Ctr Dent Med Basel, Ctr Dent Imaging, Basel, Switzerland
[4] Univ Hosp Basel, Basel, Switzerland
[5] Univ Bern, Bern, Switzerland
[6] Fed Off Publ Hlth, Radiat Protect Div, Bern, Switzerland
[7] HNO Zentrum, Bern, Switzerland
[8] Inselspital Bern, Div Med Radiat Phys, Bern, Switzerland
[9] Praxisklinik, Basel, Switzerland
关键词
Diagnostic reference level; Cone beam computed tomography; Dental Radiography; Dose area product; Clinical DRL; DENTISTRY; CT;
D O I
10.1259/dmfr.20190468
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of this study was to establish diagnostic reference levels (DRLs) in the field of dental maxillofacial and ear-nose-throat (ENT) practices using cone beam CT (CBCT) in Switzerland. Methods: A questionnaire was sent to owners of CBCTs in Switzerland; to a total of 612 institutions. The answers were analyzed for each indication, provided that enough data were available. The DRLs were defined as the 75th percentile of air kerma product distribution (P-KA). Results: 227 answers were collected (38% of all centers). Third quartile of P-KA, values were obtained for five dental indications: 662 mGy cm(2) for wisdom tooth, 683 mGy cm(2) for single tooth implant treatment, 542 mGy cm(2) for tooth position anomalies, 569 mGy cm(2) for pathological dentoalveolar modifications, and 639 mGy cm(2) for endodontics. The standard field of view (FOV) size of 5 cm in diameter x 5 cm in height was proposed. Conclusions: Large ranges of FOV and P were found for a given indication, demonstrating the importance of establishing DRLs as well as FOV recommendations in view of optimizing the present practice. For now, only DRLs for dental and maxillofacial could be defined; because of a lack of ENT data, no DRL values for ENT practices could be derived from this survey.
引用
收藏
页数:8
相关论文
共 50 条
  • [11] Establishment of diagnostic reference levels in low-dose renal computed tomography
    Rawashdeh, Mohammad
    Saade, Charbel
    ACTA RADIOLOGICA, 2023, 64 (02) : 829 - 836
  • [12] Establishment of diagnostic reference levels in computed tomography for select procedures in Pudhuchery, India
    Saravanakumar, A.
    Vaideki, K.
    Govindarajan, K. N.
    Jayakumar, S.
    JOURNAL OF MEDICAL PHYSICS, 2014, 39 (01) : 50 - 55
  • [13] Establishment of diagnostic reference levels in computed tomography in two large hospitals in Oman
    Bouchareb, Yassine
    Al-Maimani, Amal
    Al-Balushi, Al-Yaqin
    Al-Kalbani, Maather
    Al-Maskari, Hasina
    Al-Dhuhli, Humoud
    Al-Kindi, Faiza
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (17) : 2148 - 2155
  • [14] Establishing national paediatric computed tomography diagnostic reference levels in Ghana
    Shirazu, Issahaku
    Sackey, Theophilus A.
    Edziah, Raymond
    Boateng, Yaw Mensah
    Schandorf, Cyril.
    HEALTH AND TECHNOLOGY, 2024, 14 (06) : 1187 - 1198
  • [15] 2021 NATIONAL DIAGNOSTIC REFERENCE LEVELS FOR PAEDIATRIC COMPUTED TOMOGRAPHY IN EGYPT
    Abdou, Sayed E.
    Salama, Dina H.
    Ahmad, Khaled A.
    Sallam, Abdelsattar M.
    El-Sayed, El-Sayed Mahmoud
    Talaat, M. S.
    El-Farrash, Rania A.
    Vassileva, J.
    RADIATION PROTECTION DOSIMETRY, 2022, 198 (07) : 423 - 433
  • [16] Establishing national diagnostic reference levels (DRLs) for computed tomography in Egypt
    Salama, Dina Husseiny
    Vassileva, Jenia
    Mahdaly, Gamal
    Shawki, Mona
    Salama, Ahmad
    Gilley, Debbie
    Rehani, Madan Mohan
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 39 : 16 - 24
  • [17] Establishment of national diagnostic reference levels for computed tomography procedures in Sri Lanka: first nationwide dose survey
    Amalaraj, T.
    Satharasinghe, Duminda
    Pallewatte, Aruna
    Jeyasugiththan, Jeyasingam
    JOURNAL OF RADIOLOGICAL PROTECTION, 2022, 42 (02)
  • [18] Establishment and utilisation of national diagnostic reference level for adult computed tomography examinations in Ghana
    Issahaku, Shiraz
    Boadu, Mary
    Inkoom, Stephen
    Hasford, Francis
    Sackey, Theophilus A.
    RADIATION PROTECTION DOSIMETRY, 2024, 200 (06) : 564 - 571
  • [19] PATIENT GROUPING FOR DOSE SURVEYS AND ESTABLISHMENT OF DIAGNOSTIC REFERENCE LEVELS IN PAEDIATRIC COMPUTED TOMOGRAPHY
    Vassileva, J.
    Rehani, M.
    RADIATION PROTECTION DOSIMETRY, 2015, 165 (1-4) : 81 - 85
  • [20] ESTABLISHMENT OF LOCAL DIAGNOSTIC REFERENCE LEVELS FOR COMMON PROCEDURES OF COMPUTED TOMOGRAPHY IN YAZD PROVINCE
    Zamani, Hamed
    Masjedi, Hamidreza
    Omidi, Reza
    Hosein Zare, Mohammad
    RADIATION PROTECTION DOSIMETRY, 2020, 188 (02) : 222 - 231