Establishment of national diagnostic reference levels in dental cone beam computed tomography in Switzerland

被引:14
|
作者
Deleu, Marine [1 ,2 ]
Dagassan, Dorothea [3 ]
Berg, Isabelle [4 ]
Bize, Julie [1 ]
Dula, Karl [5 ]
Lenoir, Vincent [2 ]
Ott, Barbara [6 ]
Ott, Julien G. [7 ]
Verdun, Francis R. [1 ]
Weber, Robert [8 ]
Ziglinas, Panagiotis [9 ]
Zingariello, Cesare [2 ]
Merce, Marta Sans [2 ]
机构
[1] Lausanne Univ Hosp, Inst Radiat Phys, Lausanne, Switzerland
[2] Univ Hosp Geneva, Dept Radiol, Geneva, Switzerland
[3] Univ Basel, Univ Ctr Dent Med Basel, Ctr Dent Imaging, Basel, Switzerland
[4] Univ Hosp Basel, Basel, Switzerland
[5] Univ Bern, Bern, Switzerland
[6] Fed Off Publ Hlth, Radiat Protect Div, Bern, Switzerland
[7] HNO Zentrum, Bern, Switzerland
[8] Inselspital Bern, Div Med Radiat Phys, Bern, Switzerland
[9] Praxisklinik, Basel, Switzerland
关键词
Diagnostic reference level; Cone beam computed tomography; Dental Radiography; Dose area product; Clinical DRL; DENTISTRY; CT;
D O I
10.1259/dmfr.20190468
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of this study was to establish diagnostic reference levels (DRLs) in the field of dental maxillofacial and ear-nose-throat (ENT) practices using cone beam CT (CBCT) in Switzerland. Methods: A questionnaire was sent to owners of CBCTs in Switzerland; to a total of 612 institutions. The answers were analyzed for each indication, provided that enough data were available. The DRLs were defined as the 75th percentile of air kerma product distribution (P-KA). Results: 227 answers were collected (38% of all centers). Third quartile of P-KA, values were obtained for five dental indications: 662 mGy cm(2) for wisdom tooth, 683 mGy cm(2) for single tooth implant treatment, 542 mGy cm(2) for tooth position anomalies, 569 mGy cm(2) for pathological dentoalveolar modifications, and 639 mGy cm(2) for endodontics. The standard field of view (FOV) size of 5 cm in diameter x 5 cm in height was proposed. Conclusions: Large ranges of FOV and P were found for a given indication, demonstrating the importance of establishing DRLs as well as FOV recommendations in view of optimizing the present practice. For now, only DRLs for dental and maxillofacial could be defined; because of a lack of ENT data, no DRL values for ENT practices could be derived from this survey.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Establishment of reference mandibular plane for anterior alveolar morphology evaluation using cone beam computed tomography
    Rong-yang WANG
    Min HAN
    Hong LIU
    Chun-ling WANG
    Hong-hong XIAN
    Lei ZHANG
    Shi-jie ZHANG
    Dong-xu LIU
    Journal of Zhejiang University-Science B(Biomedicine & Biotechnology), 2013, (06) : 525 - 525
  • [32] Establishment of reference mandibular plane for anterior alveolar morphology evaluation using cone beam computed tomography
    Rong-yang Wang
    Min Han
    Hong Liu
    Chun-ling Wang
    Hong-hong Xian
    Lei Zhang
    Shi-jie Zhang
    Dong-xu Liu
    Journal of Zhejiang University SCIENCE B, 2012, 13 : 942 - 947
  • [33] Establishment of reference mandibular plane for anterior alveolar morphology evaluation using cone beam computed tomography
    Rongyang WANG Min HAN Hong LIU Chunling WANG Honghong XIAN Lei ZHANG Shijie ZHANG Dongxu LIU Department of Orthodontics Shandong Provincial Key Laboratory of Oral Biomedicine Shandong University Jinan China Department of Stomatology Qianfoshan Hospital of Shandong Province Jinan China Department of Stomatology the Second Hospital of Shandong University Jinan China
    Journal of Zhejiang University-Science B(Biomedicine & Biotechnology), 2012, 13 (11) : 942 - 947
  • [34] Clinical guidelines for dental cone-beam computed tomography
    Takafumi Hayashi
    Yoshinori Arai
    Toru Chikui
    Sachiko Hayashi-Sakai
    Kazuya Honda
    Hiroko Indo
    Taisuke Kawai
    Kaoru Kobayashi
    Shumei Murakami
    Masako Nagasawa
    Munetaka Naitoh
    Eiji Nakayama
    Yutaka Nikkuni
    Hideyoshi Nishiyama
    Noriaki Shoji
    Shigeaki Suenaga
    Ray Tanaka
    Oral Radiology, 2018, 34 : 89 - 104
  • [35] Simulated Dental Cone Beam Computed Tomography Using Timepix
    Baek, Seung H.
    Uher, Josef
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [36] Quality Control in Dental Cone-Beam Computed Tomography
    Huang, Jin-Feng
    Chen, Xiao-Zhao
    Wang, Hong
    APPLIED SCIENCES-BASEL, 2021, 11 (17):
  • [37] Proposed Diagnostic Reference Levels in the Missouri/Southern Illinois Region Associated with Cone-beam Computed Tomography Use in Endodontics
    Popkowski, Arthur
    Rhodes, S. Craig
    Hatton, John F.
    JOURNAL OF ENDODONTICS, 2024, 50 (07) : 966 - 975
  • [38] Cone beam computed tomography and its application in dental practice
    Correia, Francisco
    Salgado, Abel
    REVISTA PORTUGUESA DE ESTOMATOLOGIA MEDICINA DENTARIA E CIRURGIA MAXILOFACIAL, 2012, 53 (01): : 47 - 52
  • [39] Cone Beam Computed Tomography Scanning and Diagnosis for Dental Implants
    Greenberg, Alex M.
    ORAL AND MAXILLOFACIAL SURGERY CLINICS OF NORTH AMERICA, 2015, 27 (02) : 185 - +
  • [40] Clinical guidelines for dental cone-beam computed tomography
    Hayashi, Takafumi
    Arai, Yoshinori
    Chikui, Toru
    Hayashi-Sakai, Sachiko
    Honda, Kazuya
    Indo, Hiroko
    Kawai, Taisuke
    Kobayashi, Kaoru
    Murakami, Shumei
    Nagasawa, Masako
    Naitoh, Munetaka
    Nakayama, Eiji
    Nikkuni, Yutaka
    Nishiyama, Hideyoshi
    Shoji, Noriaki
    Suenaga, Shigeaki
    Tanaka, Ray
    ORAL RADIOLOGY, 2018, 34 (02) : 89 - 104