Establishment of national diagnostic reference levels in dental cone beam computed tomography in Switzerland

被引:14
|
作者
Deleu, Marine [1 ,2 ]
Dagassan, Dorothea [3 ]
Berg, Isabelle [4 ]
Bize, Julie [1 ]
Dula, Karl [5 ]
Lenoir, Vincent [2 ]
Ott, Barbara [6 ]
Ott, Julien G. [7 ]
Verdun, Francis R. [1 ]
Weber, Robert [8 ]
Ziglinas, Panagiotis [9 ]
Zingariello, Cesare [2 ]
Merce, Marta Sans [2 ]
机构
[1] Lausanne Univ Hosp, Inst Radiat Phys, Lausanne, Switzerland
[2] Univ Hosp Geneva, Dept Radiol, Geneva, Switzerland
[3] Univ Basel, Univ Ctr Dent Med Basel, Ctr Dent Imaging, Basel, Switzerland
[4] Univ Hosp Basel, Basel, Switzerland
[5] Univ Bern, Bern, Switzerland
[6] Fed Off Publ Hlth, Radiat Protect Div, Bern, Switzerland
[7] HNO Zentrum, Bern, Switzerland
[8] Inselspital Bern, Div Med Radiat Phys, Bern, Switzerland
[9] Praxisklinik, Basel, Switzerland
关键词
Diagnostic reference level; Cone beam computed tomography; Dental Radiography; Dose area product; Clinical DRL; DENTISTRY; CT;
D O I
10.1259/dmfr.20190468
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of this study was to establish diagnostic reference levels (DRLs) in the field of dental maxillofacial and ear-nose-throat (ENT) practices using cone beam CT (CBCT) in Switzerland. Methods: A questionnaire was sent to owners of CBCTs in Switzerland; to a total of 612 institutions. The answers were analyzed for each indication, provided that enough data were available. The DRLs were defined as the 75th percentile of air kerma product distribution (P-KA). Results: 227 answers were collected (38% of all centers). Third quartile of P-KA, values were obtained for five dental indications: 662 mGy cm(2) for wisdom tooth, 683 mGy cm(2) for single tooth implant treatment, 542 mGy cm(2) for tooth position anomalies, 569 mGy cm(2) for pathological dentoalveolar modifications, and 639 mGy cm(2) for endodontics. The standard field of view (FOV) size of 5 cm in diameter x 5 cm in height was proposed. Conclusions: Large ranges of FOV and P were found for a given indication, demonstrating the importance of establishing DRLs as well as FOV recommendations in view of optimizing the present practice. For now, only DRLs for dental and maxillofacial could be defined; because of a lack of ENT data, no DRL values for ENT practices could be derived from this survey.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Survey of computed tomography practice in Ukraine and establishment of national diagnostic reference levels for most common CT examinations of adults
    Stadnyk, Larysa
    Nosyk, Olga
    Tonkopi, Elena
    Boguslavska, Alexandra
    Vassileva, Jenia
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (10) : 1142 - 1150
  • [23] Diagnostic reference levels for paediatric computed tomography
    Vawda, Zakariya
    Pitcher, Richard
    Akudugu, John
    Groenewald, Willem
    SA JOURNAL OF RADIOLOGY, 2015, 19 (02):
  • [24] A Review of Diagnostic Reference Levels in Computed Tomography
    Dawd, Jemal Edris
    Ozsahin, Dilber Uzun
    Ozsahin, Ilker
    CURRENT MEDICAL IMAGING, 2022, 18 (06) : 623 - 632
  • [25] Towards establishment of the national reference dose levels from computed tomography examinations in Tanzania
    Ngaile, JE
    Msaki, P
    Kazema, R
    JOURNAL OF RADIOLOGICAL PROTECTION, 2006, 26 (02) : 213 - 225
  • [26] Derivation of new diagnostic reference levels for neuro-paediatric computed tomography examinations in Switzerland
    Wagner, Franca
    Bize, Julie
    Racine, Damien
    Le Coultre, Regis
    Verdun, Francis
    Trueb, Philipp R.
    Treier, Reto
    JOURNAL OF RADIOLOGICAL PROTECTION, 2018, 38 (03) : 1013 - 1036
  • [27] Establishment of reference mandibular plane for anterior alveolar morphology evaluation using cone beam computed tomography
    Wang, Rong-yang
    Han, Min
    Liu, Hong
    Wang, Chun-ling
    Xian, Hong-hong
    Zhang, Lei
    Zhang, Shi-jie
    Liu, Dong-xu
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE B, 2012, 13 (11): : 942 - 947
  • [29] Establishment of reference mandibular plane for anterior alveolar morphology evaluation using cone beam computed tomography
    Rong-yang WANG
    Min HAN
    Hong LIU
    Chun-ling WANG
    Hong-hong XIAN
    Lei ZHANG
    Shi-jie ZHANG
    Dong-xu LIU
    Journal of Zhejiang University-Science B(Biomedicine & Biotechnology), 2013, 14 (06) : 525
  • [30] Establishment of diagnostic reference levels for dental intraoral radiography
    Manousaridis, G.
    Koukorava, C.
    Hourdakis, C. J.
    Kamenopoulou, V.
    Yakoumakis, E.
    Tsiklakis, K.
    RADIATION PROTECTION DOSIMETRY, 2013, 156 (04) : 455 - 457