Estimation of radiation dose and establishment of local diagnostic reference levels for computed tomography of head in pediatric population

被引:0
|
作者
Priyanka [1 ]
Kadavigere, Rajagopal [2 ]
Sukumar, Suresh [1 ]
机构
[1] Manipal Acad Higher Educ, Manipal Coll Hlth Profess, Dept Med Imaging Technol, Manipal, Karnataka, India
[2] Manipal Acad Higher Educ, Kasturba Med Coll, Dept Radio Diag & Imaging, Manipal 576104, Karnataka, India
关键词
Diagnostic reference levels; pediatric computed tomography; volumetric computed tomography dose index; dose length product; effective dose estimation; CT SCANS; RISK; CANCER; EXPOSURE; ADULT;
D O I
10.3233/XST-221172
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
BACKGROUND: Pediatric population is more sensitive to the effects of radiation than adults. Establishing diagnostic reference level (DRL) is an efficient dose optimization technique implemented by many countries for reducing radiation dose during Computed Tomography (CT) examinations. OBJECTIVES: To estimate radiation dose and establish a new local diagnostic reference level for CT head examination in the pediatric population. MATERIALS AND METHODS: We prospectively recruited 143 pediatric patients referred for CT head examination with age ranging from 0-5 years old. All patients had undergone CT head examination using the standard pediatric head protocol. Volumetric CT dose index (CTDIvol) and dose length product (DLP) were recorded. The effective dose was first calculated. Then, 75th percentile of dose indices was calculated to establish DRLs. RESULTS: DRLs in terms of CTDIvol and DLP are 23.84 mGy, 555.99 mGy.cm for patients <1 years old and 28.65 mGy, 794.99 mGy.cm for patients from 1-5 years old, respectively. Mean effective doses for <1 years old patients and 1-5 years old patients are 2.91 mSv and 2.78 mSv respectively. CONCLUSION: The study concludes that DRL in terms of CTDIvol is lower but DRL in terms of DLP and the effective dose is higher compared to a few other studies which necessitate the need for dose optimization.
引用
收藏
页码:983 / 991
页数:9
相关论文
共 50 条
  • [21] EFFECTIVE DOSE VARIATION IN PEDIATRIC COMPUTED TOMOGRAPHY: DOSE REFERENCE LEVELS IN GREECE
    Yakoumakis, E.
    Karlatira, M.
    Gialousis, G.
    Dimitriadis, A.
    Makri, T.
    Georgiou, E.
    HEALTH PHYSICS, 2009, 97 (06): : 595 - 603
  • [22] ESTIMATION OF RADIATION RISK AND ESTABLISHMENT OF DIAGNOSTIC REFERENCE LEVELS FOR PATIENTS UNDERGOING COMPUTED TOMOGRAPHY CHEST-ABDOMEN-PELVIC EXAMINATIONS IN SUDAN
    Elnour, Abdel-Rahman
    Barakat, Mustafa
    Tamam, Nissren
    Sulieman, Abdel-Moneim
    Dinar, Hussien
    Abuzaid, Mohamed M.
    RADIATION PROTECTION DOSIMETRY, 2021, 196 (1-2) : 104 - 109
  • [23] A survey of local diagnostic reference levels for the head, thorax, abdomen and pelvis computed tomography in Norway and Canada
    Tonkopi, Elena
    Wikan, Eline Jahre
    Hovland, Tor Olav
    Hogset, Sivert
    Kofod, Thomas Alexander
    Sefenu, Selasi K.
    Hughes-Ryan, Emily
    d'Entremont-O'Connell, Dakota
    Gunn, Catherine
    Holter, Tanja
    Johansen, Safora
    ACTA RADIOLOGICA OPEN, 2022, 11 (10)
  • [24] Establishment of diagnostic reference levels in computed tomography for select procedures in Pudhuchery, India
    Saravanakumar, A.
    Vaideki, K.
    Govindarajan, K. N.
    Jayakumar, S.
    JOURNAL OF MEDICAL PHYSICS, 2014, 39 (01) : 50 - 55
  • [25] Establishment of diagnostic reference levels in computed tomography in two large hospitals in Oman
    Bouchareb, Yassine
    Al-Maimani, Amal
    Al-Balushi, Al-Yaqin
    Al-Kalbani, Maather
    Al-Maskari, Hasina
    Al-Dhuhli, Humoud
    Al-Kindi, Faiza
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (17) : 2148 - 2155
  • [26] GREEK DOSE REFERENCE LEVELS IN PEDIATRIC PELVIS COMPUTED TOMOGRAPHY EXAMINATIONS
    Yakoumakis, Emmanouil
    Karlatira, Maria
    Makri, Triantafillia
    Kottou, Sophia
    Georgiou, Evangelos
    HEALTH PHYSICS, 2013, 104 (04): : 428 - 433
  • [27] Establishment of national diagnostic reference levels for computed tomography procedures in Sri Lanka: first nationwide dose survey
    Amalaraj, T.
    Satharasinghe, Duminda
    Pallewatte, Aruna
    Jeyasugiththan, Jeyasingam
    JOURNAL OF RADIOLOGICAL PROTECTION, 2022, 42 (02)
  • [28] Local diagnostic reference levels for paediatric chest computed tomography in Morocco
    Benmessaoud, Mounir
    Dadouch, Ahmed
    Maghnouj, Abdelmajid
    Lemmassi, Assiya
    Ouaggou, Ibrahim Ait
    Ouhadda, Hassan
    El-Ouardi, Youssef
    RADIATION PHYSICS AND CHEMISTRY, 2023, 206
  • [29] Local Diagnostic Reference Levels for Adult Computed Tomography Urography Exams
    Husremovic, Faruk
    Muharemovic, Orhan
    Dedovic, Edis
    Efendic, Alma
    Musanovic, Jasmin
    Omerovic, Rifat
    Osmanovic, Hedim
    Busuladzic, Mustafa
    DIAGNOSTICS, 2024, 14 (06)
  • [30] Establishing local diagnostic reference levels for adult computed tomography in Morocco
    El Mansouri, M.
    Talbi, M.
    Choukri, A.
    Nhila, O.
    Aabid, M.
    RADIOPROTECTION, 2022, 57 (01) : 61 - 66