Carotid intima-media thickness and hemodynamic parameters: reproducibility of manual measurements with Doppler ultrasound

被引:15
|
作者
Plasencia Martinez, Juana M. [1 ]
Garcia Santos, Jose M. [1 ]
Paredes Martinez, Maria L. [1 ]
Moreno Pastor, Ana [1 ]
机构
[1] Univ Gen Hosp Morales Meseguer, Dept Radiol, Murcia, Spain
关键词
ultrasonography; Doppler; carotid intima-media thickness; observer variation; reproducibility; CORONARY-ARTERY-DISEASE; CARDIOVASCULAR-DISEASE; MYOCARDIAL-INFARCTION; DIFFERENT SITES; RISK; PLAQUE; ATHEROSCLEROSIS; EVENTS; VARIABILITY; MEDICINE;
D O I
10.11152/mu.2013.2066.172.ci-m
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Aims: To evaluate the carotid ultrasound intra-and interobserver agreements in a common clinical scenario when making manual measurements of the intima-media thickness (IMT) and peak systolic (PSV) and end diastolic (EDV) velocities in the common (CCA) and the internal carotid (ICA) arteries. Material and methods: Three different experienced operators performed two time-point carotid ultrasounds in 21 patients with cardiovascular risk factors. Each operator measured freehand the CCA IMT three consecutive times in each examination. The CCA and ICA hemodynamic parameters were acquired just once. For our purpose we took the average (IMTmean) and maximum (IMTmax) IMT values. Quantitative variables were analyzed with the t-student, and ANOVA test. Agreements were evaluated with the Intraclass Correlation Coefficient (ICC). Results: IMTmean intraobserver agreement was better on the left (ICC: 0.930-0.851-0.916, operators 1-2-3) than on the right (ICC: 0.789-0.580-0.673, operators 1-2-3). IMTmax agreements (Left ICC: 0.821-0.723-0.853, operators 1-2-3; Right ICC: 0.669-0.421-0.480, operators 1-2-3) were lower and more variable. Interobserver agreements for IMTmean (ICC: 0.852-0.860; first-second ultrasound) and IMTmax (ICC: 0.859-0.835; first-second ultrasound) were excellent on the left, but fair-good and more variable on the right (IMTmean; ICC: 0.680-0.809; first-second ultrasound; IMTmax; 0.694-0.799; first-second ultrasound). Intraobserver agreements were fair-moderate for PSVs and good-excellent for EDVs. Interobserver agreements were good-excellent for both PSVs and EDVs. Overall, 95% confidence intervals were narrower for the left IMTmean and CCA velocities. Conclusions: Intra and interobserver agreements in carotid ultrasound are variable. In order to improve carotid IMT agreements, IMTmean is preferable over IMTmax.
引用
收藏
页码:167 / 174
页数:8
相关论文
共 50 条
  • [31] Carotid intima-media thickness is associated with media rather than intima thickness
    Sardeli, Amanda V.
    Gaspari, Arthur F.
    de Rossi, Guilherme
    de Souza, Giovana V.
    de Souza, Thiago M. F.
    Cavaglieri, Claudia R.
    Matos-Souza, Jose R.
    Nadruz, Wilson, Jr.
    Chacon-Mikahil, Mara P. T.
    ATHEROSCLEROSIS, 2017, 261 : 169 - 171
  • [32] Carotid Intima-Media Roughness and Elasticity in Hypertensive Patients With Normal Carotid Intima-Media Thickness
    Wu, Yu
    Xie, Mingxing
    Zhang, Li
    Lu, Xuan
    Cheng, Xinyao
    Lv, Qing
    JOURNAL OF ULTRASOUND IN MEDICINE, 2019, 38 (06) : 1545 - 1552
  • [33] Carotid Artery Segmentation in Ultrasound Images and Measurement of Intima-Media Thickness
    Naik, Vaishali
    Gamad, R. S.
    Bansod, P. P.
    BIOMED RESEARCH INTERNATIONAL, 2013, 2013
  • [34] Carotid intima-media thickness by ultrasound measurement: In pancreas transplant candidates
    Larsen, JL
    Lynch, T
    AlHalawani, M
    Miller, SA
    Cushing, KA
    Baxter, BT
    Stratta, RJ
    TRANSPLANTATION PROCEEDINGS, 1995, 27 (06) : 2996 - 2996
  • [35] Detection of Intima-media Thickness in Common Carotid Artery on Ultrasound Image
    He, Xing-wu
    INFORMATION ENGINEERING FOR MECHANICS AND MATERIALS RESEARCH, 2013, 422 : 165 - 171
  • [36] Reproducibility of aortic intima-media thickness in infants using edge-detection software and manual caliper measurements
    McCloskey, Kate
    Ponsonby, Anne-Louise
    Carlin, John B.
    Jachno, Kim
    Cheung, Michael
    Skilton, Michael R.
    Koleff, Jane
    Vuillermin, Peter
    Burgner, David
    CARDIOVASCULAR ULTRASOUND, 2014, 12
  • [37] Reproducibility of aortic intima-media thickness in infants using edge-detection software and manual caliper measurements
    Kate McCloskey
    Anne-Louise Ponsonby
    John B Carlin
    Kim Jachno
    Michael Cheung
    Michael R Skilton
    Jane Koleff
    Peter Vuillermin
    David Burgner
    Cardiovascular Ultrasound, 12
  • [38] Feasibility and reliability of carotid intima-media thickness measurements in nonsedated infants
    Mivelaz, Yvan
    Di Bernardo, Stefano
    Ksontini, Tatiana Boulos
    Prsa, Milan
    Vial, Yvan
    Chiolero, Arnaud
    Sekarski, Nicole
    JOURNAL OF HYPERTENSION, 2016, 34 (11) : 2227 - 2232
  • [39] Variance components analysis of carotid and femoral intima-media thickness measurements
    de Groot, E
    Zwinderman, AH
    van der Steen, AFW
    Ackerstaff, RGA
    van Swijndregt, ADM
    Bom, N
    Lie, KI
    Bruschke, AVG
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (06): : 825 - 832
  • [40] FEASIBILITY AND RELIABILITY OF CAROTID INTIMA-MEDIA THICKNESS MEASUREMENTS IN NONSEDATED INFANTS
    Di Bernardo, S.
    Mivelaz, Y.
    Ksontini, T. Boulos
    Prsa, M.
    Vial, Y.
    Chiolero, A.
    Sekarski, N.
    SWISS MEDICAL WEEKLY, 2018, 148 : 66S - 66S