Carotid intima-media thickness and hemodynamic parameters: reproducibility of manual measurements with Doppler ultrasound

被引:15
|
作者
Plasencia Martinez, Juana M. [1 ]
Garcia Santos, Jose M. [1 ]
Paredes Martinez, Maria L. [1 ]
Moreno Pastor, Ana [1 ]
机构
[1] Univ Gen Hosp Morales Meseguer, Dept Radiol, Murcia, Spain
关键词
ultrasonography; Doppler; carotid intima-media thickness; observer variation; reproducibility; CORONARY-ARTERY-DISEASE; CARDIOVASCULAR-DISEASE; MYOCARDIAL-INFARCTION; DIFFERENT SITES; RISK; PLAQUE; ATHEROSCLEROSIS; EVENTS; VARIABILITY; MEDICINE;
D O I
10.11152/mu.2013.2066.172.ci-m
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Aims: To evaluate the carotid ultrasound intra-and interobserver agreements in a common clinical scenario when making manual measurements of the intima-media thickness (IMT) and peak systolic (PSV) and end diastolic (EDV) velocities in the common (CCA) and the internal carotid (ICA) arteries. Material and methods: Three different experienced operators performed two time-point carotid ultrasounds in 21 patients with cardiovascular risk factors. Each operator measured freehand the CCA IMT three consecutive times in each examination. The CCA and ICA hemodynamic parameters were acquired just once. For our purpose we took the average (IMTmean) and maximum (IMTmax) IMT values. Quantitative variables were analyzed with the t-student, and ANOVA test. Agreements were evaluated with the Intraclass Correlation Coefficient (ICC). Results: IMTmean intraobserver agreement was better on the left (ICC: 0.930-0.851-0.916, operators 1-2-3) than on the right (ICC: 0.789-0.580-0.673, operators 1-2-3). IMTmax agreements (Left ICC: 0.821-0.723-0.853, operators 1-2-3; Right ICC: 0.669-0.421-0.480, operators 1-2-3) were lower and more variable. Interobserver agreements for IMTmean (ICC: 0.852-0.860; first-second ultrasound) and IMTmax (ICC: 0.859-0.835; first-second ultrasound) were excellent on the left, but fair-good and more variable on the right (IMTmean; ICC: 0.680-0.809; first-second ultrasound; IMTmax; 0.694-0.799; first-second ultrasound). Intraobserver agreements were fair-moderate for PSVs and good-excellent for EDVs. Interobserver agreements were good-excellent for both PSVs and EDVs. Overall, 95% confidence intervals were narrower for the left IMTmean and CCA velocities. Conclusions: Intra and interobserver agreements in carotid ultrasound are variable. In order to improve carotid IMT agreements, IMTmean is preferable over IMTmax.
引用
收藏
页码:167 / 174
页数:8
相关论文
共 50 条
  • [21] Carotid Intima-Media Thickness Measurements: Techniques and Clinical Relevance
    Coll, Blai
    Feinstein, Steven B.
    CURRENT ATHEROSCLEROSIS REPORTS, 2008, 10 (05) : 444 - 450
  • [22] Carotid intima-media thickness measurements: Techniques and clinical relevance
    Blai Coll
    Steven B. Feinstein
    Current Atherosclerosis Reports, 2008, 10 : 444 - 450
  • [23] Carotid intima-media thickness measurements in patients with multiple sclerosis
    Farzan, Marjan Rahimi
    Esmaeili, Sara
    Joghataei, Mohammad Taghi
    Hamidabad, Negin Mahmoudi
    Alavi, Seyedeh Niloufar Rafiei
    Motamed, Mohammad Reza
    Mirzaasgari, Zahra
    ANNALS OF MEDICINE AND SURGERY, 2022, 75
  • [24] Reliability of intima-media thickness measurements of the common carotid artery
    Valikovics, A.
    Paragh, G.
    Magyar, M. T.
    Csiba, L.
    Bereczki, D.
    EUROPEAN JOURNAL OF NEUROLOGY, 2004, 11 : 175 - 175
  • [25] Predictors of Carotid Intima-media Thickness
    Miguel-Soca, Pedro E.
    Nino-Escofet, Silvio
    REVISTA ESPANOLA DE CARDIOLOGIA, 2013, 66 (04): : 326 - 327
  • [26] Carotid Intima-Media Thickness for Atherosclerosis
    Nezu, Tomohisa
    Hosomi, Naohisa
    Aoki, Shiro
    Matsumoto, Masayasu
    JOURNAL OF ATHEROSCLEROSIS AND THROMBOSIS, 2016, 23 (01) : 18 - 31
  • [27] Carotid intima-media thickness (cIMT)
    Rundek, T.
    CEREBROVASCULAR DISEASES, 2014, 37 : 2 - 3
  • [28] Ultrasound measurements of carotid intima-media thickness by two semi-automated analysis systems
    Ring, M.
    Eriksson, M. J.
    Jogestrand, T.
    Caidahl, K.
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2016, 36 (05) : 389 - 395
  • [29] Design, baseline characteristics and carotid intima-media thickness reproducibility in the PARC study
    Touboul, PJ
    Vicaut, E
    Labreuche, J
    Belliard, JP
    Cohen, S
    Kownator, S
    Pithois-merli, I
    CEREBROVASCULAR DISEASES, 2005, 19 (01) : 57 - 63
  • [30] A Comparison of Automated and Manual Measurements of Intima-media Thickness in Clinical Practice
    Freire, C. M., V
    Ribeiro, A. L. P.
    Barbosa, F. B. L.
    Nogueira, A., I
    Almeida, M. C. C.
    Barbosa, M. M.
    Silva, A. C. S.
    Oliveira Jr, A. R.
    ATHEROSCLEROSIS SUPPLEMENTS, 2009, 10 (03) : 24 - 25