Carotid intima-media thickness and hemodynamic parameters: reproducibility of manual measurements with Doppler ultrasound

被引:15
|
作者
Plasencia Martinez, Juana M. [1 ]
Garcia Santos, Jose M. [1 ]
Paredes Martinez, Maria L. [1 ]
Moreno Pastor, Ana [1 ]
机构
[1] Univ Gen Hosp Morales Meseguer, Dept Radiol, Murcia, Spain
关键词
ultrasonography; Doppler; carotid intima-media thickness; observer variation; reproducibility; CORONARY-ARTERY-DISEASE; CARDIOVASCULAR-DISEASE; MYOCARDIAL-INFARCTION; DIFFERENT SITES; RISK; PLAQUE; ATHEROSCLEROSIS; EVENTS; VARIABILITY; MEDICINE;
D O I
10.11152/mu.2013.2066.172.ci-m
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Aims: To evaluate the carotid ultrasound intra-and interobserver agreements in a common clinical scenario when making manual measurements of the intima-media thickness (IMT) and peak systolic (PSV) and end diastolic (EDV) velocities in the common (CCA) and the internal carotid (ICA) arteries. Material and methods: Three different experienced operators performed two time-point carotid ultrasounds in 21 patients with cardiovascular risk factors. Each operator measured freehand the CCA IMT three consecutive times in each examination. The CCA and ICA hemodynamic parameters were acquired just once. For our purpose we took the average (IMTmean) and maximum (IMTmax) IMT values. Quantitative variables were analyzed with the t-student, and ANOVA test. Agreements were evaluated with the Intraclass Correlation Coefficient (ICC). Results: IMTmean intraobserver agreement was better on the left (ICC: 0.930-0.851-0.916, operators 1-2-3) than on the right (ICC: 0.789-0.580-0.673, operators 1-2-3). IMTmax agreements (Left ICC: 0.821-0.723-0.853, operators 1-2-3; Right ICC: 0.669-0.421-0.480, operators 1-2-3) were lower and more variable. Interobserver agreements for IMTmean (ICC: 0.852-0.860; first-second ultrasound) and IMTmax (ICC: 0.859-0.835; first-second ultrasound) were excellent on the left, but fair-good and more variable on the right (IMTmean; ICC: 0.680-0.809; first-second ultrasound; IMTmax; 0.694-0.799; first-second ultrasound). Intraobserver agreements were fair-moderate for PSVs and good-excellent for EDVs. Interobserver agreements were good-excellent for both PSVs and EDVs. Overall, 95% confidence intervals were narrower for the left IMTmean and CCA velocities. Conclusions: Intra and interobserver agreements in carotid ultrasound are variable. In order to improve carotid IMT agreements, IMTmean is preferable over IMTmax.
引用
收藏
页码:167 / 174
页数:8
相关论文
共 50 条
  • [11] Comparison between automated and manual measurements of carotid intima-media thickness in clinical practice
    Vilas Freire, Claudia Maria
    Pinho Ribeiro, Antonio Luiz
    Lima Barbosa, Felipe Batista
    Nogueira, Anelise Impelisiere
    Costa de Almeida, Maria Cristina
    Barbosa, Marcia Melo
    Quintao Lana, Angela Maria
    Simoes e Silva, Ana Cristina
    Ribeiro-Oliveira, Antonio, Jr.
    VASCULAR HEALTH AND RISK MANAGEMENT, 2009, 5 : 811 - 817
  • [12] Carotid intima-media thickness
    Pezzano, Antonio
    La Carrubba, Salvatore
    Gullace, Giuseppe
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2006, 7 (07) : 555 - 559
  • [13] An in vivo evaluation of the reproducibility of intima-media thickness measurements of the carotid artery segments using B-mode ultrasound
    van Swijndregt, ADM
    De Lange, EE
    De Groot, E
    Ackerstaff, RGA
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1999, 25 (03): : 323 - 330
  • [14] THE CAROTID INTIMA-MEDIA THICKNESS AND CARDIAC TISSUE DOPPLER IN HYPERTENSION
    Catena, C.
    Colussi, G. L.
    Petri, C.
    Marzano, L.
    Di Fabio, A.
    Valeri, M.
    Sechi, L. A.
    JOURNAL OF HYPERTENSION, 2009, 27 : S383 - S383
  • [15] Measurement of carotid artery intima-media thickness.: Analysis of reproducibility
    Baguet, JP
    Moreau-Gaudry, A
    Siché, JP
    Tremel, F
    Cinquin, P
    Mallion, JM
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 2000, 93 (09): : 1139 - 1144
  • [16] A Comparison of Ultrasound Intima-Media Thickness Measurements of the Left and Right Common Carotid Artery
    Loizou, Christos P.
    Nicolaides, Andrew
    Kyriacou, Efthyvoulos
    Georghiou, Niki
    Griffin, Maura
    Pattichis, Constantinos S.
    IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE, 2015, 3
  • [17] Ultrasound measurement of atherosclerosis - Response: Carotid intima-media thickness measurements in intervention studies
    Bots, ML
    STROKE, 2004, 35 (05) : E87 - E88
  • [18] Black blood carotid mill vascular measurements correlate with ultrasound intima-media thickness
    Mani, V
    Aguiar, SH
    Weinshelbaum, KB
    Itskovich, VV
    Postley, JE
    Fuster, V
    Fayad, ZA
    CIRCULATION, 2005, 112 (17) : U419 - U420
  • [19] An update on carotid ultrasound measurement of intima-media thickness - Discussion
    Guerci, A
    Nissen, SE
    Crouse, JR
    Ballantyne, C
    AMERICAN JOURNAL OF CARDIOLOGY, 2002, 89 (4A): : 38B - 39B
  • [20] Use of portable ultrasound to measure carotid intima-media thickness
    Goonewardena, S
    Lammertin, G
    Ward, RP
    Lang, RM
    DeCara, JM
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) : 368A - 368A