Sensitive determination of iron(III) by gold electrode modified with 2-mercaptosuccinic acid self-assembled monolayer

被引:54
|
作者
Shervedani, Reza Karimi [1 ]
Hatefi-Mehrjardi, Abdolhamid [1 ]
Asadi-Farsani, Ashar [1 ]
机构
[1] Univ Isfahan, Dept Chem, Esfahan 8174673441, Iran
关键词
iron(III) determination; 2-mercaptosuccinic acid; self-assembled monolayer; Osteryoung square wave; voltammetry; electrochemical impedance; spectroscopy;
D O I
10.1016/j.aca.2007.08.037
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Preparation and application of gold 2-mercaptosuccinic acid self-assembled monolayer (Au-MSA SAM) electrode for determination of iron(III) in the presence of iron(II) is described by cyclic voltammetry, electrochemical impedance spectroscopy, and Osteryoung square wave voltammetry. The square wave voltammograms showed a sharp peak around positive potentials +0.250 V that was used for construction of the calibration curve. Parameters influencing the method were optimized. A linear range calibration curve from 1.0 x 10(-10) to 6.0 x 10(-9) M iron(III) with a detection limit of 3.0 x 10(-11) M and relative standard deviation (R.S.D.) of 6.5% for n = 8 at 1.0 x 10-9 M iron(III) was observed in the best conditions. Possible interferences from the coexisting ions were also investigated. The results demonstrated that sensor could be used for determination of iron(III) in the presence of various ions. The validity of the method and applicability of the sensor were successfully tested by determining of iron(III) in natural waters (tap and mineral waters) and in a pharmaceutical sample (Venofer (R) ampoule) without interference from sample matrix. The experimental data are presented and discussed from which the new sensor is characterized. (c) 2007 Elsevier B.V All rights reserved.
引用
收藏
页码:164 / 171
页数:8
相关论文
共 50 条
  • [31] Simultaneous determination of dopamine and ascorbic acid at an in-site functionalized self-assembled monolayer on gold electrode
    Lei, Z
    Jia, JB
    Zou, XQ
    Dong, SJ
    ELECTROANALYSIS, 2004, 16 (17) : 1413 - 1418
  • [32] Self-assembled monolayer modified gold electrodes for traces Cu(II) determination
    Profumo, A
    Merli, D
    Pesavento, M
    ANALYTICA CHIMICA ACTA, 2006, 557 (1-2) : 45 - 51
  • [33] Highly Sensitive Aluminium(III) Ion Sensor Based on a Self-assembled Monolayer on a Gold Nanoparticles Modified Screen-printed Carbon Electrode
    Wong Pooi See
    Lee Yook Heng
    Sheila Nathan
    Analytical Sciences, 2015, 31 : 997 - 1003
  • [34] Highly Sensitive Aluminium(III) Ion Sensor Based on a Self-assembled Monolayer on a Gold Nanoparticles Modified Screen-printed Carbon Electrode
    See, Wong Pooi
    Heng, Lee Yook
    Nathan, Sheila
    ANALYTICAL SCIENCES, 2015, 31 (10) : 997 - 1003
  • [35] Direct determination of rutin with Au electrode modified by 2-aminoethanethiol self-assembled monolayer
    Xu Qing
    Wang Rong
    Lu Qiuyan
    Ye Wenbo
    Cao Xiaowei
    Wu Xiaqin
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 34 (07) : 971 - 974
  • [36] Enantioselectivity of redox reaction of DOPA at the gold electrode modified with a self-assembled monolayer of homocysteine
    Nakanishi, Takuya
    Matsunaga, Mariko
    Nagasaka, Makoto
    Asahi, Toru
    Osaka, Tetsuya
    Journal of the American Chemical Society, 2006, 128 (41): : 13322 - 13323
  • [37] Electroanalysis of ascorbate and dopamine at a gold electrode modified with a positively charged self-assembled monolayer
    Raj, CR
    Ohsaka, T
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2001, 496 (1-2) : 44 - 49
  • [38] Electrochemical detection of copper(II) at a gold electrode modified with a self-assembled monolayer of penicillamine
    L. M. Niu
    H. Q. Luo
    N. B. Li
    L. Song
    Journal of Analytical Chemistry, 2007, 62 : 470 - 474
  • [39] Noninvasive Sialic Acid Detection at Cell Membrane by Using Phenylboronic Acid Modified Self-Assembled Monolayer Gold Electrode
    Matsumoto, Akira
    Sato, Naoko
    Kataoka, Kazunori
    Miyahara, Yuji
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2009, 131 (34) : 12022 - +
  • [40] Voltammetric detection of uric acid in the presence of ascorbic acid at a gold electrode modified with a self-assembled monolayer of heteroaromatic thiol
    Raj, CR
    Ohsaka, T
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2003, 540 : 69 - 77