Sensitive determination of iron(III) by gold electrode modified with 2-mercaptosuccinic acid self-assembled monolayer

被引:54
|
作者
Shervedani, Reza Karimi [1 ]
Hatefi-Mehrjardi, Abdolhamid [1 ]
Asadi-Farsani, Ashar [1 ]
机构
[1] Univ Isfahan, Dept Chem, Esfahan 8174673441, Iran
关键词
iron(III) determination; 2-mercaptosuccinic acid; self-assembled monolayer; Osteryoung square wave; voltammetry; electrochemical impedance; spectroscopy;
D O I
10.1016/j.aca.2007.08.037
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Preparation and application of gold 2-mercaptosuccinic acid self-assembled monolayer (Au-MSA SAM) electrode for determination of iron(III) in the presence of iron(II) is described by cyclic voltammetry, electrochemical impedance spectroscopy, and Osteryoung square wave voltammetry. The square wave voltammograms showed a sharp peak around positive potentials +0.250 V that was used for construction of the calibration curve. Parameters influencing the method were optimized. A linear range calibration curve from 1.0 x 10(-10) to 6.0 x 10(-9) M iron(III) with a detection limit of 3.0 x 10(-11) M and relative standard deviation (R.S.D.) of 6.5% for n = 8 at 1.0 x 10-9 M iron(III) was observed in the best conditions. Possible interferences from the coexisting ions were also investigated. The results demonstrated that sensor could be used for determination of iron(III) in the presence of various ions. The validity of the method and applicability of the sensor were successfully tested by determining of iron(III) in natural waters (tap and mineral waters) and in a pharmaceutical sample (Venofer (R) ampoule) without interference from sample matrix. The experimental data are presented and discussed from which the new sensor is characterized. (c) 2007 Elsevier B.V All rights reserved.
引用
收藏
页码:164 / 171
页数:8
相关论文
共 50 条
  • [21] Simultaneous detection of ascorbic acid and dopamine at gold electrode modified with a self-assembled monolayer of cystamine
    Raj, CR
    Ohsaka, T
    ELECTROCHEMISTRY, 1999, 67 (12) : 1175 - 1177
  • [22] Electrochemical behavior of gold electrode modified densely with self-assembled monolayer of ferrocenylalkanethiol
    Zhou Mi
    Zhu Jun-Jie
    Zhao Jian-Wei
    CHINESE JOURNAL OF INORGANIC CHEMISTRY, 2007, 23 (01) : 46 - 50
  • [23] Recognition and detection of dsDNA at a thionalid self-assembled monolayer modified gold electrode
    Wang, SF
    Wang, W
    Cai, HC
    SENSORS AND ACTUATORS B-CHEMICAL, 2005, 104 (01) : 8 - 14
  • [24] Photoinduced electron transfer at a gold electrode modified with a self-assembled monolayer of fullerene
    Imahori, H
    Azuma, T
    Ozawa, S
    Yamada, H
    Ushida, K
    Ajavakom, A
    Norieda, H
    Sakata, Y
    CHEMICAL COMMUNICATIONS, 1999, (06) : 557 - 558
  • [25] Application of a gold electrode, modified by a self-assembled monolayer of 2-mercaptodecylhydroquinone, to the electroanalysis of hemoglobin
    Jingdong Zhang
    Kyoungja Seo
    Il Cheol Jeon
    Analytical and Bioanalytical Chemistry, 2003, 375 : 539 - 543
  • [26] Application of a gold electrode, modified by a self-assembled monolayer of 2-mercaptodecylhydroquinone, to the electroanalysis of hemoglobin
    Zhang, JD
    Seo, K
    Jeon, IC
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 375 (04) : 539 - 543
  • [28] Self-assembled monolayer gold electrode for surfactant analysis
    Marc Gerlache
    Zühre Senturk
    Guy Quarin
    Jean-Michel Kauffmann
    Journal of Solid State Electrochemistry, 1997, 1 : 155 - 160
  • [29] Modification of gold electrode with a monolayer of self-assembled microgels
    Mackiewicz, Marcin
    Marcisz, Kamil
    Strawski, Marcin
    Romanski, Jan
    Stojek, Zbigniew
    Karbarz, Marcin
    ELECTROCHIMICA ACTA, 2018, 268 : 531 - 538
  • [30] Self-assembled monolayer gold electrode for surfactant analysis
    Gerlache, M
    Senturk, Z
    Quarin, G
    Kauffmann, JM
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 1997, 1 (02) : 155 - 160