Assessing the Accuracy Factors in the Determination of Postoperative Acetabular Cup Orientation Using Hybrid 2D-3D Registration

被引:3
|
作者
Zheng, Guoyan [1 ]
机构
[1] Univ Bern, ARTORG Res Ctr ISTB, CH-3014 Bern, Switzerland
关键词
Postoperative cup orientation; X-ray radiograph; 2D-3D registration; intensity-based registration; validation; TOTAL HIP-ARTHROPLASTY; ANTEVERSION; ALIGNMENT; IMAGES;
D O I
10.1007/s10278-009-9226-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Single standard anteroposterior radiograph-based methods for measuring cup orientation following total hip arthroplasty (THA) are subject to substantial errors if the individual pelvic orientation with respect to X-ray plate is not taken into consideration. Previously, we proposed to use a hybrid 2D-3D registration scheme to determine the postoperative acetabular cup orientation and developed an object-oriented cross-program called "HipMatch." However, its accuracy and robustness have not been fully investigated. To assess the potential factors that may affect the accuracy and robustness of the hybrid 2D-3D registration scheme in determining the postoperative acetabular cup orientation, a comprehensive validation study using a cadaver pelvis was performed. Nine X-ray radiographs taken from different pelvic positions relative to the X-ray plate and two computed tomography volumes of the pelvis with one acquired before the cup implantation and the other acquired after the cup implantation were used in the validation study. Potential factors that may affect the accuracy and robustness of the hybrid 2D-3D registration scheme were experimentally determined. Our experimental results demonstrate that (1) the plain radiograph-based method is not accurate; (2) the hybrid 2D-3D registration scheme helps to improve the estimation accuracy; (3) the hybrid 2D-3D registration scheme can robustly and accurately estimate the cup orientation even when a big portion of the radiograph is occluded; and (4) image resolution has minor effect on the estimation accuracy. The hybrid 2D-3D registration scheme is an accurate and robust method to measure exact cup orientation in THA. It holds the promise to be a valuable tool for clinical routine usage for providing evidence-based information.
引用
收藏
页码:769 / 779
页数:11
相关论文
共 50 条
  • [1] Assessing the Accuracy Factors in the Determination of Postoperative Acetabular Cup Orientation Using Hybrid 2D–3D Registration
    Guoyan Zheng
    Journal of Digital Imaging, 2010, 23 : 769 - 779
  • [2] Computer assisted determination of acetabular cup orientation using 2D-3D image registration
    Zheng, Guoyan
    Zhang, Xuan
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2010, 5 (05) : 437 - 447
  • [3] Postoperative calculation of acetabular cup position using 2-D-3-D registration
    Penney, Graeme P.
    Edwards, Philip J.
    Hipwell, John H.
    Slomczykowski, Mike
    Revie, Ian
    Hawkes, David J.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2007, 54 (07) : 1342 - 1348
  • [4] Computer assisted determination of acetabular cup orientation using 2D–3D image registration
    Guoyan Zheng
    Xuan Zhang
    International Journal of Computer Assisted Radiology and Surgery, 2010, 5 : 437 - 447
  • [5] 2D-3D Registration using Intensity Gradients
    Duraisamy, Prakash
    Belkhouche, Yassine
    Jackson, Stephen
    Namuduri, Kamesh
    Buckles, Bill
    SIGNAL AND DATA PROCESSING OF SMALL TARGETS 2011, 2011, 8137
  • [6] Hybrid 2D-3D ultrasound registration for navigated prostate biopsy
    Selmi, Sonia-Yuki
    Promayon, Emmanuel
    Troccaz, Jocelyne
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2018, 13 (07) : 987 - 995
  • [7] Accurate determination of hip implant wear, cup anteversion and inclination through AI automated 2D-3D registration
    Klebingat, Stefan
    Bien, Tanja
    Huertgen, Janine
    Grover, Priyanka
    Dreischarf, Marcel
    Alkhateeb, Shareef
    Jaeger, Marcus
    Rose, Georg
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2023, 41 (09) : 1985 - 1995
  • [8] A robust technique for 2D-3D registration
    Gong, Ren Hui
    Abolinaesumi, Purang
    Stewart, James
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 714 - 717
  • [9] Standardized evaluation of 2D-3D registration
    van de Kraats, EB
    Penney, GP
    Tomazevic, D
    van Walsum, T
    Niessen, WJ
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2004, PT 1, PROCEEDINGS, 2004, 3216 : 574 - 581
  • [10] Novel methods for 3D postoperative analysis of total knee arthroplasty using 2D-3D image registration
    Kim, Youngjun
    Kim, Kang-Il
    Choi, Jin Hyeok
    Lee, Kunwoo
    CLINICAL BIOMECHANICS, 2011, 26 (04) : 384 - 391