Assessing the Accuracy Factors in the Determination of Postoperative Acetabular Cup Orientation Using Hybrid 2D-3D Registration

被引:3
|
作者
Zheng, Guoyan [1 ]
机构
[1] Univ Bern, ARTORG Res Ctr ISTB, CH-3014 Bern, Switzerland
关键词
Postoperative cup orientation; X-ray radiograph; 2D-3D registration; intensity-based registration; validation; TOTAL HIP-ARTHROPLASTY; ANTEVERSION; ALIGNMENT; IMAGES;
D O I
10.1007/s10278-009-9226-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Single standard anteroposterior radiograph-based methods for measuring cup orientation following total hip arthroplasty (THA) are subject to substantial errors if the individual pelvic orientation with respect to X-ray plate is not taken into consideration. Previously, we proposed to use a hybrid 2D-3D registration scheme to determine the postoperative acetabular cup orientation and developed an object-oriented cross-program called "HipMatch." However, its accuracy and robustness have not been fully investigated. To assess the potential factors that may affect the accuracy and robustness of the hybrid 2D-3D registration scheme in determining the postoperative acetabular cup orientation, a comprehensive validation study using a cadaver pelvis was performed. Nine X-ray radiographs taken from different pelvic positions relative to the X-ray plate and two computed tomography volumes of the pelvis with one acquired before the cup implantation and the other acquired after the cup implantation were used in the validation study. Potential factors that may affect the accuracy and robustness of the hybrid 2D-3D registration scheme were experimentally determined. Our experimental results demonstrate that (1) the plain radiograph-based method is not accurate; (2) the hybrid 2D-3D registration scheme helps to improve the estimation accuracy; (3) the hybrid 2D-3D registration scheme can robustly and accurately estimate the cup orientation even when a big portion of the radiograph is occluded; and (4) image resolution has minor effect on the estimation accuracy. The hybrid 2D-3D registration scheme is an accurate and robust method to measure exact cup orientation in THA. It holds the promise to be a valuable tool for clinical routine usage for providing evidence-based information.
引用
收藏
页码:769 / 779
页数:11
相关论文
共 50 条
  • [31] Effective 2D-3D Medical Image Registration using Support Vector Machine
    Qi, Wenyan
    Gu, Lixu
    Zhao, Qiang
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 5386 - +
  • [32] Improving 2D-3D Registration Optimization Using Learned Prostate Motion Data
    De Silva, Tharindu
    Cool, Derek W.
    Yuan, Jing
    Romognoli, Cesare
    Fenster, Aaron
    Ward, Aaron D.
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2013, PT II, 2013, 8150 : 124 - 131
  • [33] 3D interfractional patient position verification using 2D-3D registration of orthogonal images
    Jans, H. -S.
    Syme, A. M.
    Rathee, S.
    Fallone, B. G.
    MEDICAL PHYSICS, 2006, 33 (05) : 1420 - 1439
  • [34] An Indoor Crowd Simulation Using a 2D-3D Hybrid Data Model
    Jun, Chulmin
    Kim, Hyeyoung
    COMPUTATIONAL SCIENCE AND ITS APPLICATIONS - ICCSA 2009, PT I, 2009, 5592 : 397 - 412
  • [35] Model Self-Adaptive Display for 2D-3D Registration
    Zhang, Peng
    Miao, Yangyang
    Shan, Dongri
    Li, Shuang
    INTERNATIONAL JOURNAL OF IMAGE AND GRAPHICS, 2023,
  • [36] Fast 2D-3D registration for navigation system of surgical robot
    Iwashita, Y
    Kurazume, R
    Hasegawa, T
    Konishi, K
    Nakamoto, M
    Hashizume, M
    2005 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), VOLS 1-4, 2005, : 897 - 903
  • [37] 2D-3D Spatial Registration for Remote Inspection of Power Substations
    Mattioli, Leandro
    Cardoso, Alexandre
    Lamounier, Edgard
    ENERGIES, 2020, 13 (23)
  • [38] Enhancing the depth perception of DSA images with 2D-3D registration
    Zhang, Xiaofeng
    Deng, Yongzhi
    Tian, Congyu
    Chen, Shu
    Wang, Yuanqing
    Zhang, Meng
    Wang, Qiong
    Liao, Xiangyun
    Si, Weixin
    FRONTIERS IN NEUROLOGY, 2023, 14
  • [39] Vesselness-based 2D-3D registration of the coronary arteries
    Ruijters, Daniel
    Romeny, Bart M. ter Haar
    Suetens, Paul
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2009, 4 (04) : 391 - 397
  • [40] Multilevel 2D-3D Intensity-Based Image Registration
    Lange, Annkristin
    Heldmann, Stefan
    BIOMEDICAL IMAGE REGISTRATION (WBIR 2020), 2020, 12120 : 57 - 66