Assessing the Accuracy Factors in the Determination of Postoperative Acetabular Cup Orientation Using Hybrid 2D-3D Registration

被引:3
|
作者
Zheng, Guoyan [1 ]
机构
[1] Univ Bern, ARTORG Res Ctr ISTB, CH-3014 Bern, Switzerland
关键词
Postoperative cup orientation; X-ray radiograph; 2D-3D registration; intensity-based registration; validation; TOTAL HIP-ARTHROPLASTY; ANTEVERSION; ALIGNMENT; IMAGES;
D O I
10.1007/s10278-009-9226-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Single standard anteroposterior radiograph-based methods for measuring cup orientation following total hip arthroplasty (THA) are subject to substantial errors if the individual pelvic orientation with respect to X-ray plate is not taken into consideration. Previously, we proposed to use a hybrid 2D-3D registration scheme to determine the postoperative acetabular cup orientation and developed an object-oriented cross-program called "HipMatch." However, its accuracy and robustness have not been fully investigated. To assess the potential factors that may affect the accuracy and robustness of the hybrid 2D-3D registration scheme in determining the postoperative acetabular cup orientation, a comprehensive validation study using a cadaver pelvis was performed. Nine X-ray radiographs taken from different pelvic positions relative to the X-ray plate and two computed tomography volumes of the pelvis with one acquired before the cup implantation and the other acquired after the cup implantation were used in the validation study. Potential factors that may affect the accuracy and robustness of the hybrid 2D-3D registration scheme were experimentally determined. Our experimental results demonstrate that (1) the plain radiograph-based method is not accurate; (2) the hybrid 2D-3D registration scheme helps to improve the estimation accuracy; (3) the hybrid 2D-3D registration scheme can robustly and accurately estimate the cup orientation even when a big portion of the radiograph is occluded; and (4) image resolution has minor effect on the estimation accuracy. The hybrid 2D-3D registration scheme is an accurate and robust method to measure exact cup orientation in THA. It holds the promise to be a valuable tool for clinical routine usage for providing evidence-based information.
引用
收藏
页码:769 / 779
页数:11
相关论文
共 50 条
  • [21] Assessing accuracy factors in deformable 2D/3D medical image registration using a statistical pelvis model
    Yao, JH
    Taylor, R
    NINTH IEEE INTERNATIONAL CONFERENCE ON COMPUTER VISION, VOLS I AND II, PROCEEDINGS, 2003, : 1329 - 1334
  • [22] Patient positioning using a fast robust 2D-3D registration strategy with a registration quality evaluator
    Wu, J.
    Kim, M.
    Peters, J.
    Liu, C.
    Palta, J.
    Li, J.
    Samant, S. S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S43 - S43
  • [23] An Open Platform for 2D-3D Image Registration Experiments
    Balter, J.
    Long, Y.
    Folkerts, M.
    Sharp, G.
    Bortfeld, T.
    Fessler, J.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [24] FULLY AUTOMATED INITIALISATION OF 2D-3D IMAGE REGISTRATION
    Varnavas, Andreas
    Carrell, Tom
    Penney, Graeme
    2013 IEEE 10TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2013, : 568 - 571
  • [25] A Computationally Efficient Approach for 2D-3D Image Registration
    Haque, Md. Nazmul
    Pickering, Mark R.
    Biswas, Moyuresh
    Frater, Michael R.
    Scarvell, Jennie M.
    Smith, Paul N.
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 6268 - 6271
  • [26] 2D-3D REGISTRATION OF DEFORMABLE SHAPES WITH MANIFOLD PROJECTION
    Del Bue, Alessio
    Stosic, Marko
    Dodig, Marija
    Xavier, Joao
    2009 16TH IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOLS 1-6, 2009, : 1061 - +
  • [27] A Saliency-based Framework for 2D-3D Registration
    Brown, Mark
    Guillemaut, Jean-Yves
    Windridge, David
    PROCEEDINGS OF THE 2014 9TH INTERNATIONAL CONFERENCE ON COMPUTER VISION THEORY AND APPLICATIONS (VISAPP), VOL 1, 2014, : 265 - 273
  • [28] 2D-3D registration for interventional procedures: A clinical perspective
    Klingenbeck, K
    BIOMEDICAL IMAGE REGISTRATION, 2003, 2717 : 212 - 213
  • [29] STENT GRAFT REMOVAL FOR IMPROVING 2D-3D REGISTRATION
    Baust, Maximilian
    Demirci, Stefanie
    Navab, Nassir
    2009 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1 AND 2, 2009, : 1203 - 1206
  • [30] Transformation Model with Constraints for High-Accuracy of 2D-3D Building Registration in Aerial Imagery
    Zhou, Guoqing
    Luo, Qingli
    Xie, Wenhan
    Yue, Tao
    Huang, Jingjin
    Shen, Yuzhong
    REMOTE SENSING, 2016, 8 (06)