Computer assisted determination of acetabular cup orientation using 2D-3D image registration

被引:7
|
作者
Zheng, Guoyan [1 ]
Zhang, Xuan [1 ]
机构
[1] Univ Bern, Inst Surg Technol & Biomech, CH-3014 Bern, Switzerland
基金
瑞士国家科学基金会;
关键词
Post-operative cup orientation; X-ray radiograph; 2D-3D registration; Total hip arthroplasty; Pelvic tilt; TOTAL HIP-ARTHROPLASTY; CT; ANTEVERSION; PLACEMENT; COMPONENT; TILT; THA;
D O I
10.1007/s11548-010-0407-x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background 2D-3D image-based registration methods have been developed to measure acetabular cup orientation after total hip arthroplasty (THA). These methods require registration of both the prosthesis and the CT images to 2D radiographs and compute implant position with respect to a reference. The application of these methods is limited in clinical practice due to two limitations: (1) the requirement of a computer-aided design (CAD) model of the prosthesis, which may be unavailable due to the proprietary concerns of the manufacturer, and (2) the requirement of either multiple radiographs or radiograph-specific calibration, usually unavailable for retrospective studies. In this paper, we propose a new method to address these limitations. Methods A new formulation for determination of postoperative cup orientation, which couples a radiographic measurement with 2D-3D image matching, was developed. In our formulation, the radiographic measurement can be obtained with known methods so that the challenge lies in the 2D-3D image matching. To solve this problem, a hybrid 2D-3D registration scheme combining a landmark-to-ray 2D-3D alignment with a robust intensity-based 2D-3D registration was used. The hybrid 2D-3D registration scheme allows computing both the post-operative cup orientation with respect to an anatomical reference and the pelvic tilt and rotation with respect to the X-ray imaging table/plate. The method was validated using 2D adult cadaver hips. Results Using the hybrid 2D-3D registration scheme, our method showed a mean accuracy of 1.0 +/- 0.7 degrees (range from 0.1 degrees to 2.0 degrees.) for inclination and 1.7 +/- 1.2 degrees (range from 0.0 degrees to 3.9 degrees) for anteversion, taking the measurements from postoperative CT images as ground truths. Conclusions Our new solution formulation and the hybrid 2D-3D registration scheme facilitate estimation of postoperative cup orientation and measurement of pelvic tilt and rotation.
引用
收藏
页码:437 / 447
页数:11
相关论文
共 50 条
  • [1] Computer assisted determination of acetabular cup orientation using 2D–3D image registration
    Guoyan Zheng
    Xuan Zhang
    International Journal of Computer Assisted Radiology and Surgery, 2010, 5 : 437 - 447
  • [2] Assessing the Accuracy Factors in the Determination of Postoperative Acetabular Cup Orientation Using Hybrid 2D-3D Registration
    Zheng, Guoyan
    JOURNAL OF DIGITAL IMAGING, 2010, 23 (06) : 769 - 779
  • [3] Assessing the Accuracy Factors in the Determination of Postoperative Acetabular Cup Orientation Using Hybrid 2D–3D Registration
    Guoyan Zheng
    Journal of Digital Imaging, 2010, 23 : 769 - 779
  • [4] Postoperative calculation of acetabular cup position using 2-D-3-D registration
    Penney, Graeme P.
    Edwards, Philip J.
    Hipwell, John H.
    Slomczykowski, Mike
    Revie, Ian
    Hawkes, David J.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2007, 54 (07) : 1342 - 1348
  • [5] An Open Platform for 2D-3D Image Registration Experiments
    Balter, J.
    Long, Y.
    Folkerts, M.
    Sharp, G.
    Bortfeld, T.
    Fessler, J.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [6] FULLY AUTOMATED INITIALISATION OF 2D-3D IMAGE REGISTRATION
    Varnavas, Andreas
    Carrell, Tom
    Penney, Graeme
    2013 IEEE 10TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2013, : 568 - 571
  • [7] A Computationally Efficient Approach for 2D-3D Image Registration
    Haque, Md. Nazmul
    Pickering, Mark R.
    Biswas, Moyuresh
    Frater, Michael R.
    Scarvell, Jennie M.
    Smith, Paul N.
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 6268 - 6271
  • [8] 2D-3D Registration using Intensity Gradients
    Duraisamy, Prakash
    Belkhouche, Yassine
    Jackson, Stephen
    Namuduri, Kamesh
    Buckles, Bill
    SIGNAL AND DATA PROCESSING OF SMALL TARGETS 2011, 2011, 8137
  • [9] Effective 2D-3D Medical Image Registration using Support Vector Machine
    Qi, Wenyan
    Gu, Lixu
    Zhao, Qiang
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 5386 - +
  • [10] Multilevel 2D-3D Intensity-Based Image Registration
    Lange, Annkristin
    Heldmann, Stefan
    BIOMEDICAL IMAGE REGISTRATION (WBIR 2020), 2020, 12120 : 57 - 66