Evaluation of the long-term rotational stability of single-piece, acrylic intraocular lenses

被引:35
|
作者
Kwartz, J. [1 ]
Edwards, K. [1 ]
机构
[1] Bolton Hosp NHS Trust, Bolton, England
关键词
CATARACT PATIENTS; IMPLANTATION; ASTIGMATISM; SURGERY; IOLS;
D O I
10.1136/bjo.2009.163485
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objectives To assess rotational stability beyond 3 months and compare the different designs and materials of two acrylic intraocular lenses (Akreos Adapt (Bausch & Lomb, Rochester, New York, USA) and AcrySof SA60AT (Alcon, Fort Worth, Texas, USA)). Methods Post hoc analysis of retro-illumination images from a previous multicentre, contralateral eye study was used to assess intraocular lens (IOL) position and rotational stability for up to 24 months postoperatively. The image of IOL and capsular bag enabled any rotation to be calculated by measuring the angle from the horizontal to an arbitrary point on the IOL edge. The difference between the angle at the first and subsequent visits was subtracted to give a measure of IOL rotational stability. Results Data were collected from 64 eyes fitted with the Akreos IOL and 58 eyes fitted with the AcrySof IOL. Mean (SD) absolute rotation values for the two IOLs were small over the 2-year period, ranging from 2.53 degrees (2.40 degrees) to 3.2 degrees (2.57 degrees) with Akreos Adapt and 2.67 degrees (2.22 degrees) to 3.33 degrees (3.06 degrees) with AcrySof SA60AT at 6 and 24 months, respectively. The differences were not statistically significant. Using the ANSI draft toric IOL standard, the percentage of lenses rotating <= 5 degrees was 90% at 6 months, 91% at 12 months and 80% at 24 months for the Akreos lens and 89% at 6 months, 75% at 12 months and 81% at 24 months for the AcrySof lens. Conclusion Spherical, single-vision acrylic IOLs continue to show some tendency to rotate for up to 24 months postoperatively, although this is usually small. The Akreos Adapt lens may be a good platform for a toric lens product.
引用
收藏
页码:1003 / 1006
页数:4
相关论文
共 50 条
  • [41] Refractive predictability and stability of three-piece versus single-piece intraocular lenses in patients with high axial myopia
    Frings, A.
    Steinbrugger, I.
    Wissiak, E.
    Vidic, B.
    El-Shabrawi, Y.
    Ardjomand, N.
    OPHTHALMOLOGE, 2012, 109 (06): : 591 - 594
  • [42] Influence of three-piece and single-piece designs of two sharp-edge optic hydrophobic acrylic intraocular lenses on the prevention of posterior capsule opacification: a prospective, randomised, long-term clinical trial
    Zemaitiene, Reda
    Jasinskas, Vytautas
    Auffarth, Gerd U.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2007, 91 (05) : 644 - 648
  • [43] Clinical performance of Alcon SA30AL and SA60AT single-piece acrylic intraocular lenses
    Davison, JA
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (07): : 1112 - 1123
  • [44] Rotational stability of a single-piece hydrophobic acrylic intra-ocular lens in myopic and emmetropic eyes
    Fasce, Francesco
    Bianchi, Ingrid
    Knutsson, Karl Anders
    Spinelli, Alessandra
    Mauceri, Paolo
    Bolognesi, Gianluigi
    Bandello, Francesco
    ACTA OPHTHALMOLOGICA, 2018, 96 (04) : E542 - E543
  • [45] Punch and rescue technique for scleral fixation of dislocated single-piece intraocular lenses
    Micheletti, J. Morgan
    Weber, Nicole
    McCauley, Matthew B.
    Doe, Erin A.
    Coffee, Robert E.
    Caplan, Michael B.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (02): : 247 - 250
  • [46] Breakage of the haptic of a single-piece acrylic intraocular lens after transscleral fixation
    Choi, Suk Kyue
    Kim, Jin Hyoung
    Lee, Doh
    Lee, Jong Hyun
    ACTA OPHTHALMOLOGICA, 2010, 88 (08) : e346 - e347
  • [47] Rotational stability and refractive outcomes of a single-piece aspheric toric intraocular lens with 4 fenestrated haptics
    Savini, Giacomo
    Alessio, Giovanni
    Perone, Giuseppe
    Rossi, Scipione
    Schiano-Lomoriello, Domenico
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (09): : 1275 - 1279
  • [48] Irregularities on the surface of single-piece AcrySof SA60AT intraocular lenses
    Nguyen, DQ
    Saleh, TA
    Pandey, SK
    Bates, AK
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (03): : 495 - 498
  • [49] Forceps-induced cracking of a single-piece acrylic foldable intraocular lens
    Balasubramanya, R
    Rani, A
    Dada, T
    OPHTHALMIC SURGERY LASERS & IMAGING, 2003, 34 (04): : 306 - 307
  • [50] Haptic Breakage after Transscleral Fixation of a Single-Piece Acrylic Intraocular Lens
    Tanaka, Hiroki
    Fujinami, Kaoru
    Watanabe, Ken
    Noda, Toru
    Akiyama, Kunihiko
    CASE REPORTS IN OPHTHALMOLOGY, 2014, 5 (02): : 212 - 216