Evaluation of the long-term rotational stability of single-piece, acrylic intraocular lenses

被引:35
|
作者
Kwartz, J. [1 ]
Edwards, K. [1 ]
机构
[1] Bolton Hosp NHS Trust, Bolton, England
关键词
CATARACT PATIENTS; IMPLANTATION; ASTIGMATISM; SURGERY; IOLS;
D O I
10.1136/bjo.2009.163485
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objectives To assess rotational stability beyond 3 months and compare the different designs and materials of two acrylic intraocular lenses (Akreos Adapt (Bausch & Lomb, Rochester, New York, USA) and AcrySof SA60AT (Alcon, Fort Worth, Texas, USA)). Methods Post hoc analysis of retro-illumination images from a previous multicentre, contralateral eye study was used to assess intraocular lens (IOL) position and rotational stability for up to 24 months postoperatively. The image of IOL and capsular bag enabled any rotation to be calculated by measuring the angle from the horizontal to an arbitrary point on the IOL edge. The difference between the angle at the first and subsequent visits was subtracted to give a measure of IOL rotational stability. Results Data were collected from 64 eyes fitted with the Akreos IOL and 58 eyes fitted with the AcrySof IOL. Mean (SD) absolute rotation values for the two IOLs were small over the 2-year period, ranging from 2.53 degrees (2.40 degrees) to 3.2 degrees (2.57 degrees) with Akreos Adapt and 2.67 degrees (2.22 degrees) to 3.33 degrees (3.06 degrees) with AcrySof SA60AT at 6 and 24 months, respectively. The differences were not statistically significant. Using the ANSI draft toric IOL standard, the percentage of lenses rotating <= 5 degrees was 90% at 6 months, 91% at 12 months and 80% at 24 months for the Akreos lens and 89% at 6 months, 75% at 12 months and 81% at 24 months for the AcrySof lens. Conclusion Spherical, single-vision acrylic IOLs continue to show some tendency to rotate for up to 24 months postoperatively, although this is usually small. The Akreos Adapt lens may be a good platform for a toric lens product.
引用
收藏
页码:1003 / 1006
页数:4
相关论文
共 50 条
  • [21] Single-piece acrylic intraocular lens implantation in children
    Sony, P
    Khokhar, S
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (09): : 1818 - 1819
  • [22] Intraoperative explantation of two single-piece hydrophobic acrylic intraocular lenses due to surface deposits
    M S Hickman
    L Werner
    N Mamalis
    E Sung
    D Goldstein
    D T Vroman
    S K Pandey
    Eye, 2006, 20 : 1054 - 1060
  • [23] Long-term rotational stability and visual outcomes of a single-piece hydrophilic acrylic toric IOL:a 1.5-year follow-up
    Balázs Gy?ngy?ssy
    Paul Jirak
    Ulrich Sch?nherr
    International Journal of Ophthalmology, 2017, (04) : 573 - 578
  • [24] Long-term rotational stability and visual outcomes of a single-piece hydrophilic acrylic toric IOL: a 1.5-year follow-up
    Gyoengyoessy, Balazs
    Jirak, Paul
    Schoenherr, Ulrich
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2017, 10 (04) : 573 - 578
  • [25] A simple technique of intraocular lenses explantation for single-piece foldable lenses
    Bhaumik, Arup
    Mitra, Santanu
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2017, 65 (12) : 1428 - 1430
  • [26] Retrospective ultrasound biomicroscopic analysis of single-piece sulcus-fixated acrylic intraocular lenses
    Vasavada, Abhay R.
    Raj, Shetal M.
    Karve, Shrihari
    Vasavada, Viraj
    Vasavada, Vaishali
    Theoulakis, Panagiotis
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (05): : 771 - 777
  • [27] Intraoperative explantation of two single-piece hydrophobic acrylic intraocular lenses due to surface deposits
    Hickman, M. S.
    Werner, L.
    Mamalis, N.
    Sung, E.
    Goldstein, D.
    Vroman, D. T.
    Pandey, S. K.
    EYE, 2006, 20 (09) : 1054 - 1060
  • [28] Rotational stability of a single-piece hydrophobic acrylic intraocular lens:: New method for high-precision rotation control
    Weinand, Frank
    Jung, Annette
    Stein, Alexandra
    Pfuetzner, Andreas
    Becker, Ralph
    Pavlovic, Sima
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (05): : 800 - 803
  • [29] Implantation and capsular bag stability of single-piece, foldable EasAcryl 1 intraocular lenses
    Scorolli, L
    Scorolli, L
    Ricci, R
    Di Silvestre, L
    Morara, M
    Della Valle, V
    Meduri, R
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (03): : 521 - 526
  • [30] Comparison of short-term posterior capsule opacification rates between single-piece and three-piece hydrophobic acrylic intraocular lenses
    Zare, Mohammad-Ali
    Heidari, Helia
    Hashemi, Hassan
    Mohammadi, S-Farzad
    IRANIAN JOURNAL OF OPHTHALMOLOGY, 2008, 20 (02): : 50 - 51