Evaluation of the long-term rotational stability of single-piece, acrylic intraocular lenses

被引:35
|
作者
Kwartz, J. [1 ]
Edwards, K. [1 ]
机构
[1] Bolton Hosp NHS Trust, Bolton, England
关键词
CATARACT PATIENTS; IMPLANTATION; ASTIGMATISM; SURGERY; IOLS;
D O I
10.1136/bjo.2009.163485
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objectives To assess rotational stability beyond 3 months and compare the different designs and materials of two acrylic intraocular lenses (Akreos Adapt (Bausch & Lomb, Rochester, New York, USA) and AcrySof SA60AT (Alcon, Fort Worth, Texas, USA)). Methods Post hoc analysis of retro-illumination images from a previous multicentre, contralateral eye study was used to assess intraocular lens (IOL) position and rotational stability for up to 24 months postoperatively. The image of IOL and capsular bag enabled any rotation to be calculated by measuring the angle from the horizontal to an arbitrary point on the IOL edge. The difference between the angle at the first and subsequent visits was subtracted to give a measure of IOL rotational stability. Results Data were collected from 64 eyes fitted with the Akreos IOL and 58 eyes fitted with the AcrySof IOL. Mean (SD) absolute rotation values for the two IOLs were small over the 2-year period, ranging from 2.53 degrees (2.40 degrees) to 3.2 degrees (2.57 degrees) with Akreos Adapt and 2.67 degrees (2.22 degrees) to 3.33 degrees (3.06 degrees) with AcrySof SA60AT at 6 and 24 months, respectively. The differences were not statistically significant. Using the ANSI draft toric IOL standard, the percentage of lenses rotating <= 5 degrees was 90% at 6 months, 91% at 12 months and 80% at 24 months for the Akreos lens and 89% at 6 months, 75% at 12 months and 81% at 24 months for the AcrySof lens. Conclusion Spherical, single-vision acrylic IOLs continue to show some tendency to rotate for up to 24 months postoperatively, although this is usually small. The Akreos Adapt lens may be a good platform for a toric lens product.
引用
收藏
页码:1003 / 1006
页数:4
相关论文
共 50 条
  • [31] Comparison of stability between a modular intraocular lens system and a single-piece hydrophobic acrylic intraocular lens
    SooHoo, Jeffrey R.
    Lane, Stephen S.
    Cionni, Robert J.
    Berdahl, John P.
    Sussman, Glenn R.
    Kahook, Malik Y.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (12): : 1821 - 1825
  • [32] Transscleral Fixation of Single-Piece Hydrophilic Acrylic Lenses With No Eyelets
    Taskapili, Muhittin
    Gulkilik, Gokhan
    Kocabora, Mehmet Selim
    Nilay, Kandemir
    OPHTHALMIC SURGERY LASERS & IMAGING, 2009, 40 (04) : 434 - 436
  • [33] Single-piece acrylic intraocular lens implantation in children - Reply
    Wilson, ME
    Trivedi, RH
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (09): : 1819 - 1819
  • [34] Pigment release and secondary glaucoma after implantation of single-piece acrylic intraocular lenses in the ciliary sulcus
    Uy, Harvey Siy
    Chan, Pik Sha T.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 142 (02) : 330 - 332
  • [35] Comparison of Long-Term Rotational Stability of Three Commonly Implanted Intraocular Lenses
    Schartmueller, Daniel
    Schwarzenbacher, Luca
    Meyer, Elias Laurin
    Schriefl, Sabine
    Leydolt, Christina
    Menapace, Rupert
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2020, 220 : 72 - 81
  • [36] Single-piece lenses.
    Blakesley, Thomas H.
    PHILOSOPHICAL MAGAZINE, 1903, 6 (31-36) : 521 - 524
  • [37] Outbreak of Subacute-Onset Toxic Anterior Segment Syndrome Associated with Single-Piece Acrylic Intraocular Lenses
    Oshika, Tetsuro
    Eguchi, Shuichiro
    Goto, Hiroshi
    Ohashi, Yuichi
    OPHTHALMOLOGY, 2017, 124 (04) : 519 - 523
  • [38] Pattern of posterior capsule opacification models 2 years postoperatively with 2 single-piece acrylic intraocular lenses
    Nixon, Don R.
    Woodcock, Michael G.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (06): : 929 - 934
  • [39] Transscleral fixation of a single-piece hydrophilic foldable acrylic intraocular lens
    Taskapili, Muhittin
    Gulkilik, Gokhan
    Engin, Gunay
    Kocabora, Mehmet Selim
    Yilmazli, Cemil
    Ozsutcu, Mustafa
    Kucuksahin, Hasan
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2007, 42 (02): : 256 - 261
  • [40] Light scattering and light transmittance in a series of calcified single-piece hydrophilic acrylic intraocular lenses of the same design
    Barra, Daniel
    Werner, Liliana
    Pacini Costa, Joao Luiz
    Morris, Caleb
    Ribeiro, Tiago
    Ventura, Bruna Vieira
    Dornelles, Fabio
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (01): : 121 - 128