Increasing the measurement accuracy for wave aberrations of an optical system using the intensity distribution of a focused light beam

被引:1
|
作者
Sirazetdinov, V. S. [1 ]
Dmitriev, I. Yu [1 ]
Linsky, P. M. [1 ]
Nikitin, N., V [1 ]
机构
[1] Sci Res Inst Optoelect Instrument Engn, Sosnovyi Bor, Leningrad Regio, Russia
关键词
POINT-SPREAD FUNCTION; PHASE RETRIEVAL;
D O I
10.1364/JOT.89.000197
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Subject of study. A method for enhancing the measurement accuracy for wave aberrations of an optical system by using cross-section images of a focused light beam in the presence of the image's amplitude distortions is described. Method. The measurement procedure includes determining the wave aberrations of the optical system individually for each of the beam cross-section images recorded at different sides from the focal plane and subsequently averaging the obtained wave aberrations. Main results. The utilized method for obtaining the wave aberrations of an optical system involves analysis and processing of the aberration-distorted intensity distributions in the cross-section images of a focused light beam that are recorded in a plane before and after the focal plane. Noticeably, the presence of intensity nonuniformities in the light beam cross-sections that do not result from the wave aberrations inevitably causes measurement errors. The effect of such amplitude noise on the measurement accuracy can be suppressed manifold by recording and processing an additional image of the beam cross-section positioned at a particularly selected distance on the opposite side to the focusing plane. This is followed by averaging the wave aberrations obtained for each of these images. If the amplitude and aberrational distortions of the intensity distribution have similar profiles in one of the recording planes, they are added, and they increase the degree of nonuniformity of the total intensity distribution. However, the profiles of the amplitude and aberrational distortions of the intensity distribution in the other plane are mutually opposite, which reduces the degree of distribution nonuniformity. This effect allows the measurement errors caused by amplitude noise to be compensated by arithmetically averaging the wave aberrations obtained individually for each image. We demonstrate that the variation in the measured values of the root mean square deviation of the wave front of the beam of up to 20%-30% from the individual measurements of the wave aberrations in the presence of noise can be reduced to several percent using the proposed method. Practical significance. Amplitude distortions in the images of the cross-sections of a beam that are not caused by aberrations are ubiquitous because they are present in, e.g., high-aperture, apodized, or off-axis optical systems. Measurement of the wave aberrations of such optical systems by the standard method using one image of a focused beam does not provide accurate results. The modification of this measurement technique proposed in this paper enables the extension of its application area to the aforementioned systems while maintaining its characteristic measurement accuracy at lambda/20. (C) 2022 Optica Publishing Group.
引用
收藏
页码:197 / 204
页数:8
相关论文
共 50 条
  • [31] Measurement of the intensity profile of a Gaussian baser beam near its focus using an optical fiber
    Sheu, Fang-Wen
    Chang, Ching-Huang
    AMERICAN JOURNAL OF PHYSICS, 2007, 75 (10) : 956 - 959
  • [32] Improvement of beam-adjustment accuracy by beam-intensity distribution measurement on a 2nd shaping aperture in electron-beam writing systems
    Nishimura, S
    Ogasawara, M
    Tojo, T
    EMERGING LITHOGRAPHIC TECHNOLOGIES V, 2001, 4343 : 684 - 691
  • [33] Visualization of Temperature Distribution around Focal Area and Near Fields of High Intensity Focused Ultrasound Using a 3D Measurement System
    Iwahashi, Toshihide
    Tang, Tianhan
    Matsui, Kazuhiro
    Fujiwara, Keisuke
    Itani, Kazunori
    Yoshinaka, Kiyoshi
    Azuma, Takashi
    Takagi, Shu
    Sakuma, Ichiro
    ADVANCED BIOMEDICAL ENGINEERING, 2018, 7 : 1 - 7
  • [34] EFFECT OF ABERRATIONS OF THE OPTICAL-SYSTEM OF A LENS-ARRAY ILLUMINATOR ON THE LIGHT-DISTRIBUTION IN THE ILLUMINATED FIELD
    KORNEICHIK, VL
    NATAROVSKII, SN
    SOVIET JOURNAL OF OPTICAL TECHNOLOGY, 1990, 57 (08): : 479 - 481
  • [35] Three-dimensional light distribution near the focus of a tightly focused beam of few-cycle optical pulses
    Romallosa, KM
    Bantang, J
    Saloma, C
    PHYSICAL REVIEW A, 2003, 68 (03):
  • [36] Variance of measurement noise and signal-to-noise ratio in the optical beam phase reconstruction from the intensity distribution
    Aksenov, V.P.
    Atmospheric and Oceanic Optics(English Edition of the Journal Optika Atmosfery i Okeana), 1993, 6 (11):
  • [37] Measurement system for large size laser beam intensity distribution based on CCD diffuse transmission imaging
    Pang, Miao
    Rong, Jian
    Yuan, Xuewen
    Gao, Xueyan
    Zhou, Shan
    2013 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTOELECTRONIC MEASUREMENT TECHNOLOGY AND SYSTEMS, 2013, 9046
  • [38] Light-Transmitting Characteristics of Optical Fiber in Laser Spot Distribution Measurement System
    Luo Jie
    Qin Laian
    Hou Zaihong
    Guan Wenlu
    Zhu Wenyue
    Zhang Silong
    Tan Fengfu
    ACTA OPTICA SINICA, 2021, 41 (12)
  • [39] Wave optical analysis of light-emitting diode beam shaping using microlens arrays
    Büttner, A
    Zeitner, UD
    OPTICAL ENGINEERING, 2002, 41 (10) : 2393 - 2401
  • [40] Optical tomography system for process measurement using light-emitting diodes as a light source
    Abdul Rahim, RHJ
    Chan, KS
    OPTICAL ENGINEERING, 2004, 43 (05) : 1251 - 1257