Visualization of Temperature Distribution around Focal Area and Near Fields of High Intensity Focused Ultrasound Using a 3D Measurement System

被引:2
|
作者
Iwahashi, Toshihide [1 ,4 ]
Tang, Tianhan [1 ]
Matsui, Kazuhiro [1 ]
Fujiwara, Keisuke [2 ]
Itani, Kazunori [2 ]
Yoshinaka, Kiyoshi [3 ]
Azuma, Takashi [1 ]
Takagi, Shu [1 ]
Sakuma, Ichiro [1 ]
机构
[1] Univ Tokyo, Dept Engn, Tokyo, Japan
[2] HITACHI Ltd, Healthcare Business Unit, Tokyo, Japan
[3] Natl Inst Adv Ind Sci & Technol, Hlth Res Inst, Tsukuba, Ibaraki, Japan
[4] Fac Engn, Bunkyo Ku, Room 722,Bldg 14,7-3-1 Hongo, Tokyo 1138656, Japan
来源
关键词
HIFU; ultrasound; MTLC; visualization; minimally invasive;
D O I
10.14326/abe.7.1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
High intensity focused ultrasound (HIFU) is one of the promising minimally invasive therapeutic methods. Focused ultrasound creates coagulation area with minimally invasiveness. Reduction of thermal damage in non-target area during HIFU therapy as well as effective coagulation of the target area are important. In developing a safe and effective HIFU system and control algorithm for HIFU beam manipulation, experimental evaluation of 3D temperature distribution is required to verify the performance of the system under development. In previous studies, several methods for evaluating 3D temperature distribution were introduced, such as MRI thermometry. This method requires consideration of MRI compatibility of the HIFU system. Other methods including thermocouples and thermochromic liquid crystal (TLC) sheet have been used to visualize temperature distribution in experimental acoustic phantoms. However, there were several limitations in evaluating 3D temperature distribution during HIFU exposure. In this study, a 3D temperature distribution measurement system using micro-capsulated thermochromic liquid crystal (MTLC) was developed. We fabricated an optically transparent temperature sensitive phantom containing MTLC that emits a reflectance spectrum depending on temperature. The 3D temperature distribution was visualized using a light sheet method. The temperature distribution in the optical phantom during HIFU exposure was determined with errors as low as 0.6 degrees C. Using this system, temperature distribution induced by HIFU exposure was visualized using different focusing methods to evaluate their performance.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 50 条
  • [2] Transvaginal 3D image-guided high intensity focused ultrasound array
    Held, R
    Nguyen, TN
    Vaezy, S
    4th International Symposium on Therapeutic Ultrasound, 2005, 754 : 170 - 173
  • [3] High intensity focused ultrasound induced in vivo large volume hyperthermia under 3D MRI temperature control
    Tillander, Matti
    Hokland, Steffen
    Koskela, Julius
    Dam, Hogni
    Andersen, Niels Peter
    Pedersen, Michael
    Tanderup, Kari
    Ylihautala, Mika
    Kohler, Max
    MEDICAL PHYSICS, 2016, 43 (03) : 1539 - 1549
  • [4] Design and Ex Vivo Evaluation of a 3D High Intensity Focused Ultrasound System for Tumor Treatment with Tissue Ablation
    Lweesy, K.
    Fraiwan, L.
    Al-Shalabi, M.
    Mohammad, L.
    Al-Oglah, R.
    26TH SOUTHERN BIOMEDICAL ENGINEERING CONFERENCE: SBEC 2010, 2010, 32 : 556 - 559
  • [5] 3D Organ Motion Prediction for MR-Guided High Intensity Focused Ultrasound
    Arnold, Patrik
    Preiswerk, Frank
    Fasel, Beat
    Salomir, Rares
    Scheffier, Klaus
    Cattin, Philippe C.
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION (MICCAI 2011), PT II, 2011, 6892 : 623 - 630
  • [6] Temperature Measurement Using Passive Harmonics during High Intensity Focused Ultrasound Exposures in Porcine Tissue
    Dong, Hu
    Qian, Shengyou
    Tan, Qiaolai
    Zou, Xiao
    Liu, Bei
    ACTA PHYSICA POLONICA A, 2018, 134 (02) : 524 - 528
  • [7] A portable high-intensity focused ultrasound system for the pancreas with 3D electronic steering: a preclinical study in a swine model
    Chang, Won
    Lee, Jae Young
    Lee, Jae Hwan
    Bae, Jae Seok
    Cho, Yeon Jin
    Kang, Kook Jin
    Son, Keonho
    Chung, Yul Ri
    Lee, Kyoung Bun
    Han, Joon Koo
    ULTRASONOGRAPHY, 2018, 37 (04) : 298 - 306
  • [8] Determining temperature distribution in tissue in the focal plane of the high (>100 W/cm2) intensity focused ultrasound beam using phase shift of ultrasound echoes
    Karwat, Piotr
    Kujawska, Tamara
    Lewin, Peter A.
    Secomski, Wojciech
    Gambin, Barbara
    Litniewski, Jerzy
    ULTRASONICS, 2016, 65 : 211 - 219
  • [9] 3D Temperature Field Reconstruction Using Ultrasound Sensing System
    Liu, Yuqian
    Ma, Tong
    Cao, Chengyu
    Wang, Xingwei
    SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE SYSTEMS 2016, 2016, 9803
  • [10] Design and ex vivo kidney evaluation of a high-intensity focused ultrasound transducer and 3D positioner
    Khaldon Lweesy
    Luay Fraiwan
    Alaa Shatat
    Ghassan Abdo
    Abduallah Dawodiah
    Mohammad Sameer
    Medical & Biological Engineering & Computing, 2010, 48 : 269 - 276