Visualization of Temperature Distribution around Focal Area and Near Fields of High Intensity Focused Ultrasound Using a 3D Measurement System

被引:2
|
作者
Iwahashi, Toshihide [1 ,4 ]
Tang, Tianhan [1 ]
Matsui, Kazuhiro [1 ]
Fujiwara, Keisuke [2 ]
Itani, Kazunori [2 ]
Yoshinaka, Kiyoshi [3 ]
Azuma, Takashi [1 ]
Takagi, Shu [1 ]
Sakuma, Ichiro [1 ]
机构
[1] Univ Tokyo, Dept Engn, Tokyo, Japan
[2] HITACHI Ltd, Healthcare Business Unit, Tokyo, Japan
[3] Natl Inst Adv Ind Sci & Technol, Hlth Res Inst, Tsukuba, Ibaraki, Japan
[4] Fac Engn, Bunkyo Ku, Room 722,Bldg 14,7-3-1 Hongo, Tokyo 1138656, Japan
来源
关键词
HIFU; ultrasound; MTLC; visualization; minimally invasive;
D O I
10.14326/abe.7.1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
High intensity focused ultrasound (HIFU) is one of the promising minimally invasive therapeutic methods. Focused ultrasound creates coagulation area with minimally invasiveness. Reduction of thermal damage in non-target area during HIFU therapy as well as effective coagulation of the target area are important. In developing a safe and effective HIFU system and control algorithm for HIFU beam manipulation, experimental evaluation of 3D temperature distribution is required to verify the performance of the system under development. In previous studies, several methods for evaluating 3D temperature distribution were introduced, such as MRI thermometry. This method requires consideration of MRI compatibility of the HIFU system. Other methods including thermocouples and thermochromic liquid crystal (TLC) sheet have been used to visualize temperature distribution in experimental acoustic phantoms. However, there were several limitations in evaluating 3D temperature distribution during HIFU exposure. In this study, a 3D temperature distribution measurement system using micro-capsulated thermochromic liquid crystal (MTLC) was developed. We fabricated an optically transparent temperature sensitive phantom containing MTLC that emits a reflectance spectrum depending on temperature. The 3D temperature distribution was visualized using a light sheet method. The temperature distribution in the optical phantom during HIFU exposure was determined with errors as low as 0.6 degrees C. Using this system, temperature distribution induced by HIFU exposure was visualized using different focusing methods to evaluate their performance.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 50 条
  • [31] Measurement the 3D temperature distribution in the combustion zone using acoustic tomography and nolinear wavefont tracing
    Zhang, Wei
    Jiang, Genshan
    Sun, Jianhao
    Liu, Yuechao
    MEASUREMENT, 2024, 229
  • [32] Observation of dynamic structure using high-speed ultrasound 3D imaging system
    Miura, M
    Tamura, Y
    Yanagida, H
    Ishihara, C
    Okada, N
    Ishigami, S
    Muramatsu, T
    2003 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2003, : 1871 - 1874
  • [33] Treatable focal region modulated by double excitation signal superimposition to realize platform temperature distribution during transcranial brain tumor therapy with high-intensity focused ultrasound
    常诗卉
    曹睿
    张亚斌
    王佩国
    吴世敬
    钱宇晗
    菅喜岐
    Chinese Physics B, 2018, 27 (07) : 590 - 599
  • [34] Treatable focal region modulated by double excitation signal superimposition to realize platform temperature distribution during transcranial brain tumor therapy with high-intensity focused ultrasound
    Chang, Shi-Hui
    Cao, Rui
    Zhang, Ya-Bin
    Wang, Pei-Guo
    Wu, Shi-Jing
    Qian, Yu-Han
    Jian, Xi-Qi
    CHINESE PHYSICS B, 2018, 27 (07)
  • [35] Fem simulation on the 3D temperature distribution of large area hot filament chemical vapor deposition system
    Xu, Feng
    Zuo, Dunwen
    Lu, Wenzhuang
    Li, Lei
    Wang, Min
    Jixie Gongcheng Xuebao/Chinese Journal of Mechanical Engineering, 2007, 43 (06): : 21 - 25
  • [36] Visualization of high dimensional data using an automated 3D star co-ordinate system
    Shaik, Jahangheer S.
    Yeasin, Mohammed
    2006 IEEE INTERNATIONAL JOINT CONFERENCE ON NEURAL NETWORK PROCEEDINGS, VOLS 1-10, 2006, : 1339 - +
  • [37] Real-Time Propagation Measurement System and Scattering Object Identification by 3D Visualization by Using VRML for ETC System
    Minseok Kim
    Jun-ichi Takada
    Tetsuo Ando
    Ryuji Soma
    EURASIP Journal on Wireless Communications and Networking, 2009
  • [38] 3D Doppler Sonography and Dynamic Contrast-Enhanced MRI of Recurrent Prostate Cancer Following High Intensity Focused Ultrasound Therapy
    Bard, R.
    Barentsz, J.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (05)
  • [39] Temperature Distributions Measurement of High Intensity Focused Ultrasound using a Thin-film Thermocouple Array and Estimation of Thermal Error caused by Viscous Heating
    Matsuki, Kosuke
    Narumi, Ryuta
    Azuma, Takashi
    Yoshinaka, Kiyoshi
    Sasaki, Akira
    Okita, Kohei
    Takagi, Shu
    Matsumoto, Yoichiro
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 3722 - 3725
  • [40] Real-Time Propagation Measurement System and Scattering Object Identification by 3D Visualization by Using VRML for ETC System
    Kim, Minseok
    Takada, Jun-ichi
    Ando, Tetsuo
    Soma, Ryuji
    EURASIP JOURNAL ON WIRELESS COMMUNICATIONS AND NETWORKING, 2009,