Visualization of Temperature Distribution around Focal Area and Near Fields of High Intensity Focused Ultrasound Using a 3D Measurement System

被引:2
|
作者
Iwahashi, Toshihide [1 ,4 ]
Tang, Tianhan [1 ]
Matsui, Kazuhiro [1 ]
Fujiwara, Keisuke [2 ]
Itani, Kazunori [2 ]
Yoshinaka, Kiyoshi [3 ]
Azuma, Takashi [1 ]
Takagi, Shu [1 ]
Sakuma, Ichiro [1 ]
机构
[1] Univ Tokyo, Dept Engn, Tokyo, Japan
[2] HITACHI Ltd, Healthcare Business Unit, Tokyo, Japan
[3] Natl Inst Adv Ind Sci & Technol, Hlth Res Inst, Tsukuba, Ibaraki, Japan
[4] Fac Engn, Bunkyo Ku, Room 722,Bldg 14,7-3-1 Hongo, Tokyo 1138656, Japan
来源
关键词
HIFU; ultrasound; MTLC; visualization; minimally invasive;
D O I
10.14326/abe.7.1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
High intensity focused ultrasound (HIFU) is one of the promising minimally invasive therapeutic methods. Focused ultrasound creates coagulation area with minimally invasiveness. Reduction of thermal damage in non-target area during HIFU therapy as well as effective coagulation of the target area are important. In developing a safe and effective HIFU system and control algorithm for HIFU beam manipulation, experimental evaluation of 3D temperature distribution is required to verify the performance of the system under development. In previous studies, several methods for evaluating 3D temperature distribution were introduced, such as MRI thermometry. This method requires consideration of MRI compatibility of the HIFU system. Other methods including thermocouples and thermochromic liquid crystal (TLC) sheet have been used to visualize temperature distribution in experimental acoustic phantoms. However, there were several limitations in evaluating 3D temperature distribution during HIFU exposure. In this study, a 3D temperature distribution measurement system using micro-capsulated thermochromic liquid crystal (MTLC) was developed. We fabricated an optically transparent temperature sensitive phantom containing MTLC that emits a reflectance spectrum depending on temperature. The 3D temperature distribution was visualized using a light sheet method. The temperature distribution in the optical phantom during HIFU exposure was determined with errors as low as 0.6 degrees C. Using this system, temperature distribution induced by HIFU exposure was visualized using different focusing methods to evaluate their performance.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 50 条
  • [11] Design and ex vivo kidney evaluation of a high-intensity focused ultrasound transducer and 3D positioner
    Lweesy, Khaldon
    Fraiwan, Luay
    Shatat, Alaa
    Abdo, Ghassan
    Dawodiah, Abduallah
    Sameer, Mohammad
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2010, 48 (03) : 269 - 276
  • [12] Intensity-based image registration for 3D spatial compounding using a freehand 3D ultrasound system
    Pagoulatos, N
    Haynor, DR
    Kim, Y
    MEDICAL IMAGE 2002: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2002, 4687 : 438 - 449
  • [13] A method for 3D measurement with high resolution using ultrasound spherical waves
    Matani, A
    Nambu, M
    Kondo, A
    Oshiro, O
    Chihara, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1997, 36 (5B): : 3255 - 3259
  • [14] Method for 3D measurement with high resolution using ultrasound spherical waves
    Matani, Ayumu
    Nambu, Masayuki
    Kondo, Atushi
    Oshiro, Osamu
    Chihara, Kunihiro
    Japanese Journal of Applied Physics, Part 1: Regular Papers & Short Notes & Review Papers, 1997, 36 (5 B): : 3255 - 3259
  • [15] Numerical simulation of the focal region modulation to realize uniform temperature distribution during high-intensity focused ultrasound brain tumor therapy
    Chang, Shihui
    Wang, Peiguo
    Jian, Xiqi
    Shengwu Yixue Gongchengxue Zazhi/Journal of Biomedical Engineering, 2018, 35 (06): : 877 - 886
  • [16] Predicting high-intensity focused ultrasound thalamotomy lesions using 2D magnetic resonance thermometry and 3D Gaussian modeling
    Seasons, Graham M.
    Mazerolle, Erin L.
    Sankar, Tejas
    Martino, Davide
    Kiss, Zelma H. T.
    Pichardo, Samuel
    Pike, G. Bruce
    MEDICAL PHYSICS, 2019, 46 (12) : 5722 - 5732
  • [17] A visualization method for a wide range of rising temperature induced by high-intensity focused ultrasound using a tissue-mimicking phantom
    Takagi, Ryo
    Yoshinaka, Kiyoshi
    Washio, Toshikatsu
    Koseki, Yoshihiko
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2022, 39 (01) : 22 - 33
  • [18] MEASUREMENT OF LOCAL DEFORMATION FIELDS IN DENTAL COMPOSITES USING 3D OPTICAL SYSTEM
    Milosevic, Milos
    Miletic, Vesna
    Mitrovic, Nenad
    Manojlovic, Dragica
    Stankovic, Tatjana Savic
    Maneski, Tasko
    CHEMICKE LISTY, 2011, 105 : S751 - S753
  • [19] Portable high-intensity focused ultrasound system with 3D electronic steering, real-time cavitation monitoring, and 3D image reconstruction algorithms: a preclinical study in pigs
    Choi, Jin Woo
    Lee, Jae Young
    Hwang, Eui Jin
    Hwang, Inpyeong
    Woo, Sungmin
    Lee, Chang Joo
    Park, Eun-Joo
    Choi, Byung Ihn
    ULTRASONOGRAPHY, 2014, 33 (03) : 191 - 199
  • [20] Automatic spatial and temporal temperature control for MR-guided focused ultrasound using fast 3D MR thermometry and multispiral trajectory of the focal point
    Mougenot, C
    Salomir, R
    Palussière, J
    Grenier, N
    Moonen, CTW
    MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (05) : 1005 - 1015