Increasing the measurement accuracy for wave aberrations of an optical system using the intensity distribution of a focused light beam

被引:1
|
作者
Sirazetdinov, V. S. [1 ]
Dmitriev, I. Yu [1 ]
Linsky, P. M. [1 ]
Nikitin, N., V [1 ]
机构
[1] Sci Res Inst Optoelect Instrument Engn, Sosnovyi Bor, Leningrad Regio, Russia
关键词
POINT-SPREAD FUNCTION; PHASE RETRIEVAL;
D O I
10.1364/JOT.89.000197
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Subject of study. A method for enhancing the measurement accuracy for wave aberrations of an optical system by using cross-section images of a focused light beam in the presence of the image's amplitude distortions is described. Method. The measurement procedure includes determining the wave aberrations of the optical system individually for each of the beam cross-section images recorded at different sides from the focal plane and subsequently averaging the obtained wave aberrations. Main results. The utilized method for obtaining the wave aberrations of an optical system involves analysis and processing of the aberration-distorted intensity distributions in the cross-section images of a focused light beam that are recorded in a plane before and after the focal plane. Noticeably, the presence of intensity nonuniformities in the light beam cross-sections that do not result from the wave aberrations inevitably causes measurement errors. The effect of such amplitude noise on the measurement accuracy can be suppressed manifold by recording and processing an additional image of the beam cross-section positioned at a particularly selected distance on the opposite side to the focusing plane. This is followed by averaging the wave aberrations obtained for each of these images. If the amplitude and aberrational distortions of the intensity distribution have similar profiles in one of the recording planes, they are added, and they increase the degree of nonuniformity of the total intensity distribution. However, the profiles of the amplitude and aberrational distortions of the intensity distribution in the other plane are mutually opposite, which reduces the degree of distribution nonuniformity. This effect allows the measurement errors caused by amplitude noise to be compensated by arithmetically averaging the wave aberrations obtained individually for each image. We demonstrate that the variation in the measured values of the root mean square deviation of the wave front of the beam of up to 20%-30% from the individual measurements of the wave aberrations in the presence of noise can be reduced to several percent using the proposed method. Practical significance. Amplitude distortions in the images of the cross-sections of a beam that are not caused by aberrations are ubiquitous because they are present in, e.g., high-aperture, apodized, or off-axis optical systems. Measurement of the wave aberrations of such optical systems by the standard method using one image of a focused beam does not provide accurate results. The modification of this measurement technique proposed in this paper enables the extension of its application area to the aforementioned systems while maintaining its characteristic measurement accuracy at lambda/20. (C) 2022 Optica Publishing Group.
引用
收藏
页码:197 / 204
页数:8
相关论文
共 50 条
  • [41] MEASUREMENT ACCURACY ENHANCEMENT USING AN OPTICAL PROBE SYSTEM FOR ELECTRICALLY SMALL MIMO ANTENNAS
    Chung, Jae-Young
    Hong, Wonbin
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2013, 55 (02) : 238 - 241
  • [42] Automatic measurement of permittivity and permeability at microwave frequencies using normal and oblique free-wave incidence with focused beam
    Muñoz, J
    Rojo, M
    Parreño, A
    Margineda, J
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1998, 47 (04) : 886 - 892
  • [43] Antenna Measurement System using an Optical Fiber Link Millimeter Wave Generator and a Receiving System
    Kurokawa, Satoru
    Ameya, Michitaka
    Hirose, Masanobu
    2023 17TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION, EUCAP, 2023,
  • [44] Optical Deflection System to Provide Even Circular Light Distribution Using a Spot Light Source
    Diesing, Hans W.
    LED LIGHTING TECHNOLOGIES - WINNING APPROACHES, LPS 2011, 2011, : 144 - 145
  • [45] OPTICAL FIBER DIAMETER MEASUREMENT SYSTEM USING FORWARD SCATTERED-LIGHT
    SMITHGALL, DH
    WATKINS, LS
    FRAZEE, RE
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS AND CONTROL INSTRUMENTATION, 1978, 25 (02): : 108 - 112
  • [46] OPTIMIZATION OF LIGHT-BEAM WITH GAUSSIAN INTENSITY DISTRIBUTION IN DIFFRACTION LIMITED OPTICAL-SYSTEMS OF ENERGY-TRANSFER
    FEDOROV, VB
    MITYAKOV, VG
    OPTIKA I SPEKTROSKOPIYA, 1984, 57 (01): : 117 - 123
  • [47] Mode Distribution Measurement of Optical Vortex Beam using Polarization Sagnac Interferometer with Dove Prism
    Nakashima, Kei
    Kobayashi, Hirokazu
    Iwashita, Katsushi
    2017 ASIA COMMUNICATIONS AND PHOTONICS CONFERENCE (ACP), 2017,
  • [48] Performance investigation of free space optical communication system using Gaussian beam wave
    Sharma, A.
    Kaler, R. S.
    JOURNAL OF OPTOELECTRONICS AND ADVANCED MATERIALS, 2015, 17 (3-4): : 302 - 306
  • [49] Design of Optical System for Electrostatic Field Distribution Measurement Using Micromirror Array
    Kuriyama, Toshihide
    Aoi, Toshikazu
    Maeda, Hiroshi
    Itoh, Takaki
    Ueno, Yoshifumi
    Nakaie, Toshiyuki
    Matsui, Nobutika
    Okumura, Hiroyuki
    SENSORS AND MATERIALS, 2011, 23 (07) : 435 - 448
  • [50] Investigation of integration accuracy of sound-power measurement using an automated sound-intensity system
    Univ of Mississippi, University, United States
    Appl Acoust, 2 ([d]125-140):