Monitoring free light chains in serum using mass spectrometry

被引:38
|
作者
Barnidge, David R. [1 ]
Dispenzieri, Angela [1 ,2 ]
Merlini, Giampaolo [3 ]
Katzmann, Jerry A. [1 ]
Murray, David L. [1 ]
机构
[1] Mayo Clin, Dept Lab Med & Pathol, 200 1st St SW, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Med, Rochester, MN 55905 USA
[3] IRCCS Policlin S Matteo, Biotechnol Res Labs, Pavia, Italy
关键词
free light chains; kappa; l; mass spectrometry; microflow LC-ESI-Q-TOF MS; monoclonal; INTACT MONOCLONAL-ANTIBODIES; ABSOLUTE QUANTIFICATION; POSTTRANSLATIONAL MODIFICATIONS; ELECTROSPRAY-IONIZATION; PROTEIN; IDENTIFICATION; MS;
D O I
10.1515/cclm-2015-0917
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Serum immunoglobulin free light chains (FLC) are secreted into circulation by plasma cells as a by-product of immunoglobulin production. In a healthy individual the population of FLC is polyclonal as no single cell is secreting more FLC than the total immunoglobulin secreting cell population. In a person with a plasma cell dyscrasia, such as multiple myeloma (MM) or light chain amyloidosis (AL), a clonal population of plasma cells secretes a monoclonal light chain at a concentration above the normal polyclonal background. Methods: We recently showed that monoclonal immunoglobulin rapid accurate mass measurement (miRAMM) can be used to identify and quantify a monoclonal light chain (LC) in serum and urine above the polyclonal background. This was accomplished by reducing immunoglobulin disulfide bonds releasing the LC to be analyzed by microLC-ESI-Q-TOF mass spectrometry. Here we demonstrate that the methodology can also be applied to the detection and quantification of FLC by analyzing a non-reduced sample. Results: Proof of concept experiments were performed using purified FLC spiked into normal serum to assess linearity and precision. In addition, a cohort of 27 patients with AL was analyzed and miRAMM was able to detect a monoclonal FLC in 23 of the 27 patients that had abnormal FLC values by immunonephelometry. Conclusions: The high resolution and high mass measurement accuracy provided by the mass spectrometry based methodology eliminates the need for kappa/lambda ratios as the method can quantitatively monitor the abundance of the kappa and lambda polyclonal background at the same time it measures the monoclonal FLC.
引用
收藏
页码:1073 / 1083
页数:11
相关论文
共 50 条
  • [31] Haemodialysis removes free light chains from serum
    Reid, SD
    Hewins, P
    Cockwell, P
    Millard, JL
    Mead, GP
    Bradwell, AR
    CLINICA CHIMICA ACTA, 2005, 355 : S188 - S188
  • [32] Biologic variation of immunoglobulin free light chains in serum
    Braga, Federica
    Infusino, Ilenia
    Dolci, Alberto
    Panteghini, Mauro
    BIOCHIMICA CLINICA, 2013, 37 (05) : 376 - 382
  • [33] Practical considerations for the measurement of free light chains in serum
    Tate, JR
    Gill, D
    Cobcroft, R
    Hickman, PE
    CLINICAL CHEMISTRY, 2003, 49 (08) : 1252 - 1257
  • [34] Measurement of immunoglobulin free light chains in serum - Reply
    Tate, JR
    Mollee, P
    Gill, D
    CLINICAL CHEMISTRY, 2003, 49 (11) : 1958 - 1958
  • [35] How to quantify monoclonal free light chains in plasma cell disorders: which mass spectrometry technology?
    Moreau, Caroline
    Lefevre, Charles R.
    Decaux, Olivier
    ANNALS OF TRANSLATIONAL MEDICINE, 2020, 8 (15)
  • [36] Detection of Bence Jones myeloma and monitoring of myeloma chemotherapy using serum immunoassays specific for free immunoglobulin light chains.
    Bradwell, AR
    Mead, GP
    Carr-Smith, HD
    Drayson, MT
    BLOOD, 2001, 98 (11) : 157A - 157A
  • [37] FREE LIGHT CHAINS IN THE MONITORING OF THE TREATMENT OF PRIMARY AMYLOIDOSIS
    de Veas Silva, Garcia J. L.
    Lopez Velez, M. d. S.
    Espuch Oliver, A.
    De Haro Romero, M. T.
    Bermudo Guitarte, C. A.
    Rios Tamayo, R.
    Garcia Lario, J., V
    De Haro Munoz, T.
    HAEMATOLOGICA, 2018, 103 : 310 - 310
  • [38] COMPARISON OF SERUM PROTEIN IMMUNOFIXATION ELECTROPHORESIS, SERUM FREE LIGHT CHAINS AND HEAVY/LIGHT CHAIN RATIOS FOR MONITORING IGA MULTIPLE MYELOMA PATIENTS
    Harding, J.
    Margetts, C. D. E.
    Fourrier, N. J.
    Drayson, M. T.
    Mead, G. P.
    Bradwell, A. R.
    HAEMATOLOGICA-THE HEMATOLOGY JOURNAL, 2009, 94 : 610 - 610
  • [39] Serum reference intervals and diagnostic ranges for free κ and free λ immunoglobulin light chains:: Relative sensitivity for detection of monoclonal light chains
    Katzmann, JA
    Clark, RJ
    Abraham, RS
    Bryant, S
    Lymp, JF
    Bradwell, AR
    Kyle, RA
    CLINICAL CHEMISTRY, 2002, 48 (09) : 1437 - 1444
  • [40] The Clinical Significance of Serum Free Light Chains in Bladder Cancer
    Gudowska-Sawczuk, Monika
    Kudelski, Jacek
    Olkowicz, Michal
    Mlynarczyk, Grzegorz
    Chlosta, Piotr
    Mroczko, Barbara
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (09)